PubMed Health⌕ Search

Biomedical subjects

P W Stroman

Publications and source records attributed to P W Stroman.

At least 19 recordsLinked to original sources

Discrimination of errors from neuronal activity in functional MRI of the human spinal cord by means of general linear model analysis.

Functional MRI (fMRI) of the spinal cord has been demonstrated to provide reliable and sensitive maps of neuronal activity, particularly when combined across several experiments. Individual experiments reveal neuronal activity as well as errors. The dominant source of errors is hypothesized to be physiological motion, including cardiac and respiratory motion, flow of blood and cerebrospinal fluid (CSF), and motion of the spinal cord within the spinal canal. All of the hypothesized sources of error are therefore related to cardiac and respiratory motion, which can be recorded during an fMRI experiment. Analyses were carried out with a general linear model (GLM) with peripheral pulse and respiration recordings used as models of errors. The results demonstrate that the sensitivity of spinal fMRI is improved and errors are reduced when peripheral pulse traces are used in the GLM, but no improvement was detected with the inclusion of respiratory traces.

Humans↗

Simultaneous functional magnetic resonance imaging in the rat spinal cord and brain.

Functional magnetic resonance imaging (fMRI) method was developed to investigate the pattern and temporal relationship in neuronal pathways of brain and spinal cord. Signal intensity changes correlating with stimulation patterns were observed simultaneously in the rat spinal cord and brain using fMRI at 9.4 T. Electrical stimulation of the forepaw was used to elicit activity. A quadrature volume RF coil covering both brain and the cervical spinal cord was used. Sets of fast spin echo (FSE) images were acquire simultaneously for both brain and spinal cord fMRI. Experiments were repeated in single animal and across animals. Activities within the dorsal horn of the spinal cord and within the somatosensory cortex were observed consistently within each animal as well as across animals.

Animals↗

fMRI of the lumbar spinal cord during a lower limb motor task.

This study applied spinal fMRI to the lumbar spinal cord during lower limb motor activity. During active ankle movement, activity was detected in the lumbar spinal cord motor areas and sensory areas bilaterally. During passive ankle movement, activity was detected in the motor and sensory areas in lower lumbar spinal cord segments and motor activity in higher lumbar spinal cord segments. Spinal fMRI detects patterns of activity consistent with known physiology and can be used to reliably assess activity in the lumbar spinal cord during lower limb motor stimulation. This study affirms spinal fMRI as an effective tool for assessing spinal cord function and increases its potential as a clinical tool.

Female↗

Noninvasive assessment of the injured human spinal cord by means of functional magnetic resonance imaging.

STUDY DESIGN: A magnetic resonance imaging technique that enables indirect detection of neuronal activity has been developed for the spinal cord. In the present study, this method, spinal functional magnetic resonance imaging (fMRI), is applied to the first study of the injured spinal cord, with the goal of better clinical assessment of the entire cord. OBJECTIVES: The objectives of this project are: (1) to investigate the neuronal activity that can be detected in the spinal cord caudal to a chronic injury by means of spinal fMRI, and (2) to develop spinal fMRI as a clinical diagnostic tool. SETTING: Institute for Biodiagnostics, National Research Council of Canada, Winnipeg, Manitoba, Canada. METHODS: fMRI of the spinal cord was carried out in 27 volunteers with cervical or thoracic spinal cord injuries (SCIs). Of these volunteers, 18 had complete injuries, and nine had incomplete injuries. Spinal fMRI was carried out in a 1.5 T clinical MR system, using established methods. Thermal stimulation at 10 degrees C was applied to the fourth lumbar dermatome on each leg, and images were obtained of the entire lumbar spinal cord. RESULTS: Areas of neuronal activity were consistently observed in the lumbar spinal cord in response to the thermal stimulation, even when the subjects had no awareness of the sensation. The pattern of activity was notably different compared with noninjured subjects. In general, subjects with complete SCI showed absent or diminished dorsal gray matter activity, but had enhanced ventral activity, particularly contralateral to the stimulation. CONCLUSIONS: Spinal fMRI is able to provide a noninvasive assessment of the injured spinal cord that does not depend on the patient's perception of the stimulus being applied. This work was carried out on a standard clinical MRI system without modification, and so is readily applicable in most MR units. SPONSORSHIP: This work was funded by a grant from the Canadian Institutes of Health Research (CIHR).

Action Potentials↗

Functional magnetic resonance imaging of the human brain based on signal enhancement by extravascular protons (SEEP fMRI).

Functional magnetic resonance imaging (fMRI) studies of the human brain were carried out at 3 Tesla to investigate an fMRI contrast mechanism that does not arise from the blood oxygen-level dependent (BOLD) effect. This contrast mechanism, signal enhancement by extravascular protons (SEEP), involves only proton-density changes and was recently demonstrated to contribute to fMRI signal changes in the spinal cord. In the present study it is hypothesized that SEEP fMRI can be used to identify areas of neuronal activity in the brain with as much sensitivity and precision as can be achieved with BOLD fMRI. A detailed analysis of the areas of activity, signal intensity time courses, and the contrast-to-noise ratio (CNR), is also presented and compared with the BOLD fMRI results. Experiments were carried out with subjects performing a simple finger-touching task, or observing an alternating checkerboard pattern. Data were acquired using a conventional BOLD fMRI method (gradient-echo (GE) EPI, TE = 30 ms), a conventional method with reduced BOLD sensitivity (GE-EPI, TE = 12 ms), and SEEP fMRI (spin-echo (SE) EPI, TE = 22 ms). The results of this study demonstrate that SEEP fMRI may provide better spatial localization of areas of neuronal activity, and a higher CNR than conventional BOLD fMRI, and has the added benefit of lower sensitivity to field inhomogeneities.

Brain↗

Functional magnetic resonance imaging at 0.2 Tesla.

Functional magnetic resonance imaging of healthy human volunteers was carried out at 0.2 T, using proton-density weighted (TE = 24 ms) spin-echo imaging, in order to eliminate any contribution from the blood oxygenation-level dependent (BOLD) effect. The purpose of the study was to verify the existence of a proton-density change contribution to spin-echo functional magnetic resonance imaging (fMRI) data. Results demonstrated signal intensity changes in motor and sensory areas of the brain during performance of a motor task and cold sensory stimulation of the hand, with signal changes ranging from 1.7 to 2.3%. These values are consistent with 1.9% signal changes observed previously under similar conditions at 3 T. These findings confirm the proton-density change contribution to spin-echo fMRI data and support the theory of signal enhancement by extravascular water protons (SEEP) as a non-BOLD fMRI contrast mechanism. This study also demonstrates that fMRI based on the SEEP contrast mechanism can be carried out at low fields where the BOLD effect is expected to be negligible.

Body Water↗

Extravascular proton-density changes as a non-BOLD component of contrast in fMRI of the human spinal cord.

The fractional signal intensity change (Delta S/S) observed during activation in T(2)-weighted fMRI of the spinal cord has previously been shown to depend linearly on the echo time (TE) but to have a positive value of roughly 2.5% extrapolated to zero TE. In this study we investigated the origin of this finding by measuring the Delta S/S in spinal fMRI with very short TEs. Our results demonstrate that the Delta S/S does not approach zero, but has a value as high as 3.3% at TE = 11 ms. At TEs > 33 ms we observed the linear relationship between Delta S/S and TE as in previous studies. These data demonstrate that there is a non-BOLD contribution to signal changes observed in spinal fMRI. We hypothesize that this contribution is a local proton density increase due to increased water exudation from capillaries with increased blood flow during neuronal activation, and term this effect "signal enhancement by extravascular protons" (SEEP).

Humans↗

Mapping of neuronal function in the healthy and injured human spinal cord with spinal fMRI.

Functional magnetic resonance imaging of the human spinal cord is carried out with a graded thermal stimulus in order to establish the relationship between signal changes and neural activity. Studies of the lumbar spinal cord in 15 healthy subjects with 10 degrees C stimulation of the skin overlying the calf demonstrate a pattern of activity that matches the neuronal anatomy of the spinal cord. This pattern shows primarily dorsal horn activity, with expected components of motor reflex activity as well. Moreover, a later response shifting to noxious cold over time is also demonstrated with a shift to more dorsal horn activity. Signal intensity changes detected at different degrees of thermal stimulation have a biphasic nature, with much larger signal changes below 15 degrees C as the stimulus becomes noxious, and agree well with electrophysiological results reported in the literature. These findings demonstrate a strong correspondence between Spinal fMRI results and neural activity in the human spinal cord. Spinal fMRI is also applied to studies of the injured spinal cord, below the site of injury. Results consistently demonstrate activity in the spinal cord even when the subjects cannot feel the stimulus being applied. Signal intensity changes demonstrate the same stimulus-response pattern as that in noninjured subjects, but the areas of activity in the spinal gray matter are notably altered. In subjects with complete injuries, activity is absent ipsilateral to the thermal stimulation, but appears to be enhanced on the contralateral side. These findings demonstrate the reliability of Spinal fMRI and its clinical potential.

Adult↗

Functional magnetic resonance imaging of the human cervical spinal cord with stimulation of different sensory dermatomes.

Functional MR imaging (fMRI) of the cervical spinal cord was carried out in 13 healthy volunteers. A cold stimulus was applied, at different times, to three different sensory dermatome regions overlying the right hand and forearm: the thumb side of the palm, the little finger side of the palm, and the forearm below the elbow. Stimulation of these areas is expected to involve the 6(th), 8(th), and 5(th) cervical spinal cord segments respectively. Whereas true activations are expected to correspond to the region being stimulated, false activations such as arising from noise and motion, are not. The results demonstrate that clustering of active pixels into groups based on their intensity time courses discriminates false activations from true activations. Following clustering, the distribution of activity observed with fMRI matched the expected regions of neuronal activation with the different areas of stimulation on the hand and forearm.

Adult↗

Functional MRI of motor and sensory activation in the human spinal cord.

MR imaging of the cervical spinal cord was carried out on volunteers during alternated rest and either motor or sensory stimulation of one hand, in order to detect image intensity changes arising concomitant to neuronal activity. We employed both spin-echo and gradient-echo echo-planar imaging, on the right and left hands, with both symmetric and asymmetric temporal patterns of rest and stimulation. Intensity changes correlated with the time course of stimulation were consistently detected, and the magnitude of the intensity changes depended on the duration of stimulation. The activated regions in the spinal cord extended along a column on the side of the body being stimulated and included localized regions on the contralateral side, in agreement with the neural anatomy.

Cervical Vertebrae↗

Spin-echo versus gradient-echo fMRI with short echo times.

Blood-oxygen level dependent signal changes in the visual cortex were investigated as a function of echo time with spin-echo and gradient-echo EPI at 1.5 T and 3 T. The linear relationship between the fractional signal change and the echo time was apparent in all cases. Relaxation rate changes determined from the slope of this linear relation agree with published values, intercept values extrapolated to an echo time of zero, however, were 0.66% to 1.0% with spin-echo EPI, and 0.11% to 0.35% with gradient-echo EPI. Spin-echo and gradient-echo EPI can therefore yield similar signal changes at sufficiently short echo times.

Echo-Planar Imaging↗

Characterization of contrast changes in functional MRI of the human spinal cord at 1.5 T.

Contrast changes observed in functional magnetic resonance imaging in the human spinal cord were investigated with both motor and sensory tasks over a range of echo times. Data were acquired using a single-shot fast spin-echo sequence at 1.5 Tesla. Data were analyzed with two different correlation thresholds and the effects of altering the order of repeated experiments was also investigated. Plots of the fractional signal change as a function of echo time yielded linear functions with slopes corresponding to relaxation rate changes of -0.30 sec(-1) with sensory stimulation and approximately -0.50 sec(-1) with a motor task. However, the fractional signal change extrapolated to an echo time of zero was significantly greater than zero in each case and was roughly 2.5%. This suggests that in addition to the BOLD effect there is a baseline signal change which occurs concomitant to neuronal activation in the spinal cord.

Adult↗

In vivo time course studies of the tissue responses to resorbable polylactic acid implants by means of MRI.

Magnetic resonance (MR) imaging and relaxation time measurements of bioresorbable implants made of polylactic acid (PLA), as well as the surrounding tissues, were carried out over a period of 6 months to monitor the implant state and the body's responses, and to determine how these processes are reflected in MR data. Twelve rabbits each received two subcutaneous PLA implants (45 x 10 x 2 mm). Changes in tissue relaxation rates demonstrated inflammation and tissue healing time courses but were not simply linear functions of the tissue water content and so provide new insight into MR characterization of inflammatory processes.

Animals↗

BOLD MRI of the human cervical spinal cord at 3 tesla.

The feasibility of functional MRI of the spinal cord was investigated by carrying out blood oxygen-level dependent (BOLD) imaging of the human cervical spinal cord at a field of 3 T. BOLD imaging of the cervical spinal cord showed an average intensity increase of 7.0% during repeated exercise with the dominant hand with a return to baseline during rest periods. The areas of activation were predominantly on the same side of the spinal cord as the hand performing the exercise, between the levels of the sixth cervical and first thoracic spinal cord segments. The direct correspondence between these areas and those involved with the transmission of motor impulses to the hand, and reception of sensory information from the hand, demonstrates that spinal functional magnetic resonance imaging is feasible. Magn Reson Med 42:571-576, 1999.

Adult↗

Appearance of low signal intensity lines in MRI of silicone breast implants.

Magnetic resonance (MR) images of five explanted mammary prostheses were obtained with a 1.5 T GE Signa system using a conventional spin-echo pulse sequence, in order to investigate the low-intensity curvilinear lines which may be observed in MR images of silicone gel-filled breast implants under pressure from fibrous capsules. MR images showed ellipsoid prostheses, often containing multiple low-intensity curvilinear lines which in some cases presented an appearance very similar to that of the linguine sign. Upon opening the fibrous capsules, however, all of the prostheses were found to be completely intact demonstrating that the appearance of multiple low signal intensity curvilinear lines in MR images of silicone gel-filled prostheses is not necessarily a sign of prosthesis rupture. The MR image features which are specific to the linguine sign must be more precisely defined.

Breast Implants↗

Will it be feasible to insert endoprostheses under interventional MRI?

PURPOSE: Recent advances in magnetic resonance imaging (MRI) technology may provide a safer and more sensitive monitoring modality than X-ray imaging for endovascular surgical procedures. The purpose of this study was to investigate the feasibility of using MRI to monitor the insertion of endoprostheses. METHODS: The endoprostheses we studied were composed of a nitinol stent encased in a polyester sheath. These were characterized with four different MRI techniques: the fast spin-echo; spin-echo; gradient-recalled echo; and the spoiled gradient-recalled echo. The deployment of the endoprosthesis into an artery was simulated in an in vitro model and viewed using a fast spin-echo MRI technique. RESULTS: Image artifacts produced by the nitinol framework in these endoprostheses were minimal when fast spin-echo or spin-echo imaging techniques were used, improving the visibility of the device. In in vitro tests, the catheters and endoprostheses were visualized by MRI with sufficient clarity to guide the placement of a device in the model artery. CONCLUSIONS: Insertion of this type of endoprosthesis under interventional MRI guidance is feasible. The convenience and improved safety provided by interventional MR systems and "real-time" imaging capabilities are expected to make this technology an attractive alternative to X-ray imaging techniques.

Alloys↗

Theoretical modelling of the release rate of low-density lipoproteins and their breakdown products at arterial stenoses.

Arterial stenoses and luminal-surface irregularities at anastomoses cause blood-flow disturbances with slow recirculation. The authors created a computer simulation to study the rates of the release into blood of atherogenic substances such as low-density lipoproteins and their breakdown products from within the arterial walls at stenoses. Finite-difference methods were used to solve the Navier-Stokes equations (in the form of stream function and vorticity function) and the steady-state mass transfer equation for bell-shaped stenoses with two different degrees of constriction. This simulation indicated that the efflux rates of lipids and their breakdown products from the vessel walls were suppressed in the region of disturbed flow, with slow circulation distal to stenoses. The lowest efflux rate was found at the point of flow separation, and this rate was much lower than rates in regions of undisturbed flow. Therefore, this mathematical model predicts that locally disturbed blood flow at arterial stenoses and arterial anastomoses is responsible for two distinct phenomena: first, it provides favourable conditions for lipid infiltration into vessel walls; and, second, it impairs the release into the blood of atherogenic substances accumulated in the vessel wall. Such mass transfer abnormalities may account for atherogenesis and the late failures of arterial reconstructions at these sites.

Animals↗

Evaluation of effects of PAF on alveolar fluid clearance with use of NMR imaging.

Autologous serum with or without platelet-activating factor (PAF) was instilled into one lung lobe of an anesthetized cat, and changes in the regional lung water content were monitored for 4 h with proton nuclear magnetic resonance (NMR) images and relaxation time measurements. With serum as an instillate, water was cleared with a half time of approximately 670 min; after 4 h, 86 +/- 6% of that instilled remained. With PAF added to the instillate, clearance was biphasic with an initial clearance half time of approximately 30 min followed by clearance similar to that observed after serum instillation; after 4 h, 35 +/- 4% of that instilled remained. In contrast, 4 h after instillation of serum or serum plus PAF, 91 +/- 3% and 82 +/- 5%, respectively, of the instilled 125I-labeled albumin remained in the lung (P = 0.06). From transverse magnetization relaxation curves we were able to resolve two relaxation components, which we have attributed to the instilled fluid in the air spaces (relaxation time = 177 +/- 7 ms) and the tissue-bound fluid (relaxation time = 25 +/- 1 ms).

Animals↗