PubMed Health⌕ Search

Biomedical subjects

P Whittingstall

Publications and source records attributed to P Whittingstall.

2 recordsLinked to original sources

A comparison of the rheologic properties of neonatal and adult blood.

A number of studies have indicated that the rheologic properties of neonatal blood are different from those of the adult. The frequent administration of blood components to the neonate during intensive care make it important that these differences be established and their causes understood. The purpose of this study was to make a detailed comparison of the rheologic properties of neonatal and adult blood, with particular emphasis on low shear rate viscosity and rouleaux-related phenomena. The viscometric data was obtained from seven preterm (PT) and 18 normal term (NT) babies and compared with those from 18 adults (A). In the present study, viscometry was performed over a wide range of shear rates, from about 0.3 to 130 s-1, and the low shear rate data were compared with direct measurement of rouleaux formation using the Myrenne Erythrocyte Aggregometer. A major factor leading to the viscometric differences observed was the high hematocrit common in the newborn (46.8 +/- 2.1% PT, 52.8 +/- 6.1% NT, 44.1 +/- 2.5% A males, 40.5 +/- 1.9% A females). However, this tended to be compensated for by the lower plasma viscosity (1.05 +/- 0.07 mPas PT, 1.23 +/- 0.14 mPas NT, 1.34 +/- 0.08 mPas A--no sex difference) and reduced rouleaux formation observed in the newborn and more marked in the preterm baby. The lowered levels of red cell aggregation were found not to be due to cellular differences between the adults and the babies but rather to differing plasma components. The presence of the fetal variant of fibrinogen and low levels of immunoglobulins, especially IgM and IgA, are likely to be of particular importance.

Adult↗

A comparison of five methods for estimating red cell aggregation.

A comparison has been made of the responses of five techniques for estimating the degree of aggregation in red cell suspensions. They were the use of direct microscopic observation, the erythrocyte sedimentation rate test, low shear rate viscometry, the Myrenne Erythrocyte Aggregometer and the Paar Oscillating Capillary Rheometer. The test samples consisted of normal red cells suspended in buffer to which fibrinogen was added as an aggregating agent. Each test exhibited a fibrinogen threshold concentration before any response occurred. The range of response and sensitivity was highest for the sedimentation test, viscometry and the Paar device. However the simplicity and rapidity of operation of the Myrenne machine make it attractive in a clinical setting. Finally, inspite of its relative insensitivity, the microscopic technique has the great advantage of being the only one that produces unequivocal data since it is based on direct observation.

Blood Sedimentation↗