Comparison of technetium-99m-MDP, technetium-99m-WBC and technetium-99m-HIG in musculoskeletal inflammation.

UNLABELLED: This study compared three radionuclide techniques in distinguishing musculoskeletal infection from noninfectious inflammation. METHODS: Thirty-five orthopedic patients with suspected musculoskeletal infection were examined using three radionuclide techniques in sequence: triphasic bone scintigraphy, 99mTc radioleukocytes (99mTc-WBC) scintigraphy and 99mTc human immunoglobulin (99mTc-Hig) scintigraphy. Two "early" and "late" acquisitions were performed, at 4-6 hr and 20-24 hr postinjection, respectively. Patients who were diagnosed as suffering from noninflammatory lesions became the controls. We calcu"late"d for all studies one index of inflammation (Infl) as the ratio between counts in the uptake area and counts in an equal area of normal tissue. RESULTS: The "early" radiolabeled leukocytes and "late" Hig scintigraphy allowed the greatest ability to distinguish between infections and noninfectious inflammations (p < 0.011 and p < 0.016) with a sensitivity of 96.6% and 96.5% and specificity of 71% and 100%, respectively. Hig and radioleukocytes allowed distinguishing infections from noninflammatory diseases at both examinations. CONCLUSION: The "early" radioleukocyte scintigraphy allowed us to separate infections from noninfectious inflammations. In contrast, the same result can be obtained only with the "late" scan in the Hig study, but Hig mapped the spread of the inflammation into soft tissues better. Hig might be an alternative to radioleukocytes because of its simple preparation, similar accuracy and safety.

Adult↗

Total clearance and extracellular volume with 125I-iothalamate in peritoneal dialysis.

To assess treatment adequacy by calculating total clearance (CL) in patients on peritoneal dialysis (PD), fluids must be collected over 24 hours, a laborious procedure and prone to inaccuracy. CL calculation from the plasma disappearance curve of an injected tracer has none of the above inconveniences. We therefore compared creatinine clearance CR-CL with CL calculated from the plasma disappearance curve of 125I-iothalamate (IO) injected in a single intravenous bolus. Twelve patients aged 63 (44-80) years and on PD for four (1-44) months were studied in hospital. Nine plasma samples were taken for IO-CL after a bolus of 21 kBq/kg of tracer. The least-squares biexponential fitting according to Gauss-Newton-Raphson was then carried out: [Aexp(-at) + Bexp(-bt)], and clearance was calculated by the formula, IO-CL = dose/AUC, where AUC = A/a + B/b. Both CLs were normalized for 1.73 m2 of body surface. Agreement (r = 0.746, p = 0.005) for the CR-CL (6.8 +/- 1.9 mL/min) and IO-CL (7.6 +/- 1.9 mL/min) was good, with a difference of 0.9 +/- 1.4 mL/min (t = 2.182, p = 0.052). Extracellular volume (ECV), calculated from the IO plasma disappearance curve with the formula, ECV = dose/ bAUC, and including the endoperitoneal fluid, was 19.8 +/- 2.9 L (29.5 +/- 6.2% body weight).

Adult↗

Biodistribution of Tc-99m methoxy-isobutyl-isonitrile (MIBI) in humans.

Hexakis (methoxyisobutilisonitrile) technetium(I), 99mTc-MIBI, has been proposed for myocardial perfusion studies. We have evaluated the biodistribution of this new agent in normal volunteers at rest and after stress. The biodistribution of 99mTc-MIBI is characterized by rapid blood clearance and a consequently early myocardial uptake. The initial intense hepatic activity is cleared into the gallbladder at 1 h after injection, and the best target to non target ratio is observed at 60-90 min after injection. Absorbed radiation dose calculations show that the thyroid is the critical target organ (230 mRad/mCi at rest), presumably because of 99mTc-pertechnetate generated in vivo. Our results indicate that 99mTc-MIBI is a promising tracer for myocardial perfusion imaging.

Adult↗

111Indium-pentetreotide pituitary scintigraphy and hormonal responses to octreotide in acromegalic patients.

GH secreting pituitary adenomas are frequently visualized by scintigraphy with the somatostatin analogue 111Indium-pentetreotide. We studied 111Indium-pentetreotide scintigraphy and hormonal responses to octreotide in 12 acromegalic patients. Nine patients with active acromegaly were studied before pituitary adenomectomy; 6 of these and 3 other patients were studied after operation. GH was measured after a single s.c. dose of 100 micrograms of octreotide (acute test). The patients were preoperatively treated with 100 micrograms s.c. tid octreotide for 3 months as were patients who had been unsuccessfully operated; GH and IGF-I were measured at the end of this period (chronic treatment). A decrease of the hormones higher than 50% of basal values was considered a positive response in both acute test and chronic treatment. Eight/nine unoperated patients had a pituitary adenoma visualized by scintigraphy and a positive response to both the acute test and chronic treatment; one patient had no evidence of tumor at scintigraphy and he did not respond to octreotide. Scintigraphy was negative in all of the three patients cured by surgery. Six patients still had active disease after adenomectomy: scintigraphy was positive only in one case, although GH responded to octreotide treatment in all patients. Conclusions. 111In-pentetreotide scintigraphy frequently visualizes pituitary adenomas and predicts GH responses to octreotide in unoperated acromegalic patients. In unsuccessfully operated patients scintigraphy is infrequently positive and does not predict which patients will respond to octreotide. These data and the cost of 111In-pentetreotide scintigraphy do not warrant its extensive clinical use in acromegaly.

Acromegaly↗