PubMed Health⌕ Search

Biomedical subjects

Pál Koppa

Publications and source records attributed to Pál Koppa.

3 recordsLinked to original sources

Application of the fast-Fourier-transform-based volume integral equation method to model volume diffraction in shift-multiplexed holographic data storage.

Numerical simulation of diffraction on thick holographic gratings in shift-multiplexed optical data storage application is presented. The grating is generated by the interference of a spherical reference wave and a plane signal wave corresponding to a single pixel of the input data page. To describe diffraction on this weak-index-modulated grating, we use the volume integral equation in the first Born approximation. This description yields a convolution integral that can be efficiently evaluated by a 3D fast Fourier transform (FFT) technique. For a 51.2 microm recording layer thickness, a serial-divided single personal computer code was built based on parallel FFT coding principles. Diffracted electric field and Poynting-vector distributions are calculated for probe beams spatially shifted with respect to the reference beams. The shift selectivity curves show significant differences from previous analytical calculations based on paraxial propagation and infinite gratings, as they have monotonic decrease in all three directions instead of sinclike functions with Bragg nulls. With the chosen numerical aperture of 0.6 and linear polarization, both the scalar and vector calculations provided similar results within 5%.

Journal Article↗

System modeling and optimization of Fourier holographic memory.

A new fast-Fourier-transform-based model of a page-oriented holographic data-storage system is presented. The model accounts for essential system and storage material features (e.g. diffraction, noises, and saturation) and provides reliable results in the form of output images, histograms, or bit-error rates. The model is built on a modular basis and provides the possibility of working with different system versions, key components, and storage materials. Applications of the method are presented through examples of optimization of the data density, reference beam size at Gaussian beam illumination, and calculation of the storage medium's positioning tolerances in accordance with the results of test measurements.

Journal Article↗

Amplitude, phase, and hybrid ternary modulation modes of a twisted-nematic liquid-crystal display at approximately 400 nm.

Applicability of a commercial twisted-nematic liquid-crystal display is examined at approximately 400 nm. Different modulation modes predicted by Jones-matrix calculus are experimentally tested. High contrast amplitude modulation with negligible loss, high contrast and low loss hybrid ternary modulation, and 1.5pi continuous phase delay without intensity modulation and with low loss are presented. Simulation results of a 4f holographic system prove the usefulness of the high contrast for amplitude modulation, and the importance of pi phase difference between high transmission white levels in a hybrid ternary modulation.

Journal Article↗