PubMed Health⌕ Search

Biomedical subjects

PC Cheng

Publications and source records attributed to PC Cheng.

2 recordsLinked to original sources

Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction.

: X-ray cone-beam reconstruction from incomplete projection data has important practical applications, especially in microtomography. We developed expectation maximization (EM)-type and algebraic reconstruction technique (ART)-type iterative cone-beam reconstruction algorithms for metal artifact reduction and local reconstruction from truncated data. These iterative algorithms are adapted from the emission computerized tomography (CT) EM formula and the ART. A key step in our iterative algorithms is introduction of a projection mask and computation of a 3-D spatially varying relaxation factor that allows compensation for beam divergence and data incompleteness. The algorithms are simulated with projection data synthesized from mathematical phantoms. In simulation, the EM-type and ART-type iterative algorithms are demonstrated to be effective for metal artifact reduction and local region reconstruction. They perform similarly in terms of visual quality, image noise, and discrepancy between measured and reprojected data. The EM-type and ART-type iterative cone-beam reconstruction algorithms have potential for metal artifact reduction and local region reconstruction in X-ray CT.

Journal Article↗

Experimental System for X-ray Cone-Beam Microtomography

: A laboratory test of X-ray tomography employing a diverging beam of X-rays rather than the usual parallel X-ray beam is described. We chose to test and demonstrate the advantages of divergent beam tomography by imaging an extracted juvenile human premolar using an ordinary dental X-ray source and a cooled CCD camera. Experiments with a three-piece cover-glass sample and with the human tooth demonstrated that three-dimensional reconstruction can be achieved at 34 µm per pixel resolution employing an X-ray tube spot 800 µm in its smallest direction without requiring close contact with the fluorescent screen. Reconstruction of a 256 x 256 pixel single-plane image from 100 projection images took only 45 sec on a personal computer with a Pentium 166 MHz processor. We have also demonstrated a volume reconstruction of 256 x 256 x 256 voxels from the data. Successful extension of this work to submicrometer projection X-ray microscopy is predicted. Improved resolution of medical tomography is another possible application.

Journal Article↗