PubMed Health⌕ Search

Biomedical subjects

Pablo Avanzas

Publications and source records attributed to Pablo Avanzas.

27 records · Page 2Linked to original sources

C-reactive protein elevation and disease activity in patients with coronary artery disease.

AIMS: We sought to assess (1) whether C-reactive protein (CRP) is an independent predictor of future cardiovascular events after adjustment for coronary artery disease (CAD) severity and (2) whether CRP levels correlate with number of angiographically complex coronary artery stenosis. METHODS AND RESULTS: We studied 825 consecutive angina patients (mean age 63+/-10 years, 74% men), 700 with chronic stable angina (CSA) and 125 with acute coronary syndromes without ST-segment elevation (ACS). The composite endpoint of non-fatal acute myocardial infarction, hospital admission with class IIIb unstable angina and cardiac death was assessed at one year follow-up. Hs-CRP level was higher in CSA patients with the combined end-point (P=0.03) after adjustment for number of diseased coronary arteries. Hs-CRP was also significantly higher in patients with ACS compared to CSA ( P=0.004) and correlated with number of complex angiographic stenoses (r=0.36, P=0.01). Hs-CRP was also increased in patients with NYHA functional class III or IV compared to those in class I or II (p<0.0001). CONCLUSIONS: CRP levels predict future cardiovascular events independently of CAD severity and correlate with number of angiographically complex coronary artery stenosis in patients with ACS. Thus, CRP levels are a marker of atheromatous plaque vulnerability and CAD activity.

Angina Pectoris↗

Ischemia Modified Albumin for the assessment of patients presenting to the emergency department with acute chest pain but normal or non-diagnostic 12-lead electrocardiograms and negative cardiac troponin T.

BACKGROUND: The diagnosis of myocardial ischemia in patients with acute chest pain at rest but non-diagnostic electrocardiograms (ECG) is problematic. Ischemia Modified Albumin (IMA) is a new biochemical marker of ischemia, which may be useful to characterise acute coronary syndrome (ACS) patients. METHODS: We studied 131 patients (mean age 58.5 years; 95 male) presenting to the emergency department with symptoms suggestive of ACS but with normal or non-diagnostic ECGs. Cardiac troponin T (cTnT) and IMA were measured within 3 h of last chest pain episode. Based on hospital diagnostic test results, patients were classified as having ACS or non-ischemic chest pain (NICP), by two independent cardiologists unaware of IMA results. RESULTS: Mean IMA levels (U/ml) were higher in patients with ACS (98.3+/-11) compared to patients with NICP (85.5+/-15); p<0.0001. IMA levels >93.5 U/ml demonstrated a sensitivity and specificity of 75% for the diagnosis of ACS; area under the receiver operator characteristic curve 0.78 (95% CI: 0.70-0.85). If we applied the manufacturer cutoff point of 85 U/ml, the sensitivity of IMA increased to 90.6% with a specificity of 49.3% (negative predictive value=84.6%). In combination with cTnT (6-12 h) (>0.05 ng/ml), the sensitivity increased to 92.2%. After multivariate analysis, IMA levels >85 U/ml (odds ratio=14.6 [95% CI 4.4-48.4]; p<0.0001), age and prior myocardial infarction were independent predictors of ACS. CONCLUSION: IMA may be a useful biomarker for the identification of ACS in patients presenting with typical acute chest pain but normal or non-diagnostic ECGs.

Adult↗

Relation of ischemia-modified albumin (IMA) levels following elective angioplasty for stable angina pectoris to duration of balloon-induced myocardial ischemia.

The results in this study confirm and expand previous reports that ischemia-modified albumin (IMA) is an early marker of ischemia in the setting of percutaneous coronary intervention (PCI). We observed that IMA levels are related to the number of inflations, inflation pressure, and duration of inflations. It is therefore likely that IMA reflects the magnitude and duration of ischemia induced during PCI.

Angina Pectoris↗

Chronic inflammation and increased arterial stiffness in patients with cardiac syndrome X.

AIMS: Endothelial dysfunction and subangiographic atheroma have been reported in patients with cardiac syndrome X (CSX) but little is known regarding chronic inflammation and reduced arterial distensibility as pathogenic mechanisms. We assessed whether markers of inflammation and arterial distensibility differ in CSX patients compared to control subjects. METHODS AND RESULTS: We studied 30 consecutive CSX patients (mean age 57+/-6 years, 25 women) and 30 healthy controls (mean age 54+/-8 years, 25 women). High sensitivity C-reactive protein (hs-CRP) levels were significantly higher in patients with CSX compared to controls (2.6 [1.7-4.5] vs 1.5[0.7-2.7] mg/l, P=0.02). Hs-CRP levels correlated with carotid intima-media thickness (IMT) (Spearman's rho=0.51; P=0.013). CSX patients also had significantly increased mean IMT values than controls (P<0.0001). Arterial stiffness and elastic modulus were also significantly increased in CSX patients compared to control subjects (P=0.04 and P=0.04, respectively). Distensibility tended to be lower in CSX patients than controls although this difference did not reach statistical significance. CONCLUSIONS: This study showed for the first time that compared to control subjects, patients with CSX have higher hs-CRP serum levels, increased mean common carotid artery IMT and increased arterial stiffness. The role of these abnormalities in the pathogenesis of CSX deserves investigation.

Adult↗

[Comparison of echocardiographic studies made with new portable devices to conventional studies].

OBJECTIVES: The latest development in echocardiography is the hand-held ultrasound device. Previous studies have shown that portable ultrasound devices detect major cardiovascular pathology better than the physical examination, but their diagnostic accuracy is still not known. The purpose of this study was to compare the results of examinations made with portable devices to those obtained with higher-scale platforms. PATIENTS AND METHOD: 211 consecutive unselected patients were included in the study. Patients were randomly studied with a portable device and a standard platform (considered the gold standard for comparison) by cardiologists experienced in echocardiography. Parameters of cardiac morphology and function, and valvular regurgitation were compared and analyzed using the McNemar paired test. Differences of more than one grade were considered major differences. RESULTS: The subjective assessment of the studies made with the portable device was significantly worse. The correlation between estimates of left ventricular function (differences not statistically significant) was adequate, but significant differences were detected in the evaluation of left atrial enlargement, left ventricular hypertrophy, aortic root enlargement, and mitral and tricuspid regurgitation. CONCLUSIONS: Hand-held cardiac ultrasound devices do not satisfy criteria for a complete echocardiographic study. They provide accurate information about ventricular function but fail to adequately measure cardiac chambers or assess valve function.

Adult↗