Microfluidic isolation of leukocytes from whole blood for phenotype and gene expression analysis.

Technologies that enable the isolation of cell subtypes from small samples of complex populations will greatly facilitate the implementation of proteomics and genomics to human diseases. Transcriptome analysis of blood requires the depletion of contaminating erythrocytes. We report an automated microfluidic device to rapidly deplete erythrocytes from whole blood via deionized water lysis and to collect enriched leukocytes for phenotype and genomic analyses. Starting with blood from healthy subjects, we demonstrate the utility of this microfluidic cassette and lysis protocol to prepare unstimulated leukocytes, and leukocytes stimulated ex vivo with Staphylococcal enterotoxin B, which mimics some of the cellular effects seen in patients with severe bacterial infections. Microarrays are used to assess the global gene expression response to enterotoxin B. The results demonstrate that this system can isolate unactivated leukocytes from small blood samples without any significant loss, which permits more information to be obtained from subsequent analysis, and will be readily applicable to clinical settings.

Cell Separation↗

Size-based microfluidic enrichment of neonatal rat cardiac cell populations.

Native heart consists of myocytes and non-myocytes. We demonstrate here the feasibility of a size-based microfluidic separation of myocytes and non-myocytes from the neonatal rat myocardium. The device consists of a middle channel (50 microm wide, 200 microm tall, and 4 cm long) connected to adjacent side channels by microsieves (80 microm wide, 5 microm tall and 40 microm in length). The side channels increase in width in a flared shape along the length of the device to ensure constant pressure gradient across all sieves. In the first step, non-myocytes were removed from the myocytes by a conventional pre-plating method for 75 min. Subsequently, the non-myocytes were further enriched in a microfluidic device at 20 microl/min. We demonstrated that the cells in the middle and side channels maintained viability during sorting and the ability to attach and grow in culture. Upon culture for 48 h cardiomyocytes from the reservoir (control) and middle channel stained positive for cardiac Troponin I, exhibited a well developed contractile apparatus and contracted spontaneously and in response to electrical field stimulation. Most of the cells in the side channel expressed a non-myocyte marker vimetin. Fluorescent activated cell sorting indicated significant enrichment in the side channel (p < 0.001) for non-myocytes. Original cell suspension had a bimodal cell size distribution with the peaks in the range from 7-9 microm and 15-17 microm. Upon cell sorting the distribution was Gaussian in both side channel and middle channel with the peaks in the range 7-9 microm and 9-11 microm respectively, indicating that the separation by size occurred.

Animals↗

Microfluidic diffusive filter for apheresis (leukapheresis).

Apheresis is a procedure used to fractionate whole blood into its individual components. Following fractionation, the desired component is isolated and the remaining blood in many cases is returned to the donor. Leukapheresis is one type of apheresis where leukocytes (white blood cells) are selectively removed. This procedure is commonly used for blood transfusions to remove donor leukocytes from being transferred to the recipient. Apheresis also has several therapeutic applications. In this manuscript we discuss the design, fabrication and testing of a continuous flow diffusive filter, fabricated using simple soft lithographic techniques for depletion of leukocytes. This device employs micro sieves that exploit the size and shape difference between the different cell types to obtain depletion of leukocytes from whole blood. Currently, conventional apheresis methods like centrifugation or fiber mesh filtration are commonly used. A theoretical model was developed to determine the optimal shape of the diffuser to ensure that the volumetric flow through individual sieve elements is equal. This device was designed to serve as a passive device that does not require any external manipulation. Results show that for the given device design, isolation of approximately 50% of the inlet erythrocytes (red blood cells), along with depletion of >97% of the inlet leukocytes is possible at a flow rate of 5 microl min(-1). Simple modifications to the geometry and dimensions of the sieves can be made to obtain isolation of plasma.

Blood Component Removal↗

Continuous flow microfluidic device for rapid erythrocyte lysis.

Leukocyte isolation from whole blood to study inflammation requires the removal of contaminating erythrocytes. Leukocytes, however, are sensitive to prolonged exposure to hyper/hypoosmotic solutions, temperature changes, mechanical manipulation, and gradient centrifugation. Even though care is taken to minimize leukocyte activation and cell loss during erythrocyte lysis, it is often not possible to completely avoid it. Most procedures for removal of contaminating erythrocytes from leukocyte preparations are designed for bulk processing of blood, where the sample is manipulated for longer periods of time than necessary at the single-cell level. Ammonium chloride-mediated lysis is the most commonly used method to obtain enriched leukocyte populations but has been shown to cause some activation and selective loss of certain cell types. The leukocyte yield and subsequent activation status of residual leukocytes after NH(4)Cl-mediated lysis have been shown to depend on the time of exposure to the lysis buffer. We have developed a microfluidic lysis device that deals with erythrocyte removal at nearly the single-cell level. We can achieve complete lysis of erythrocytes and approximately 100% recovery of leukocytes where the cells are exposed to an isotonic lysis buffer for less than 40 s, after which the leukocytes are immediately returned to physiological conditions. Theoretically, this process can be made massively parallel to process several milliliterss of whole blood to obtain a pure leukocyte population in less than 15 min.

Animals↗