PubMed Health⌕ Search

Biomedical subjects

Pamela A Pulido

Publications and source records attributed to Pamela A Pulido.

4 recordsLinked to original sources

Hydroxyapatite-coated femoral stem survivorship at 10 years.

Ninety-six patients were implanted with the Omnifit-HA femoral stem and the Omnifit-PSL porous-coated dual-radius acetabular shell (Stryker, Mahwah, NJ) and liners that were sterilized by gamma-radiation in air. The mean age at the time of surgery was 52 years (range, 27-78 years), and male/female ratio was 54:42. The mean follow-up was 10.3 years (range, 7-12 years). The survivorship of the stem and cup was 100% and 90%, respectively. Four cups were revised for aseptic loosening, and 6 liners were exchanged. The mean polyethylene wear rate was 0.24 mm/y. Lysis was noted in 23% of the cups. No patient developed femoral lysis distally. This hydroxyapatite-coated stem continues to perform well and appears to protect against the migration of wear debris along the femoral stem.

Adult↗

The efficacy of a single daily dose of enoxaparin for deep vein thrombosis prophylaxis following total knee arthroplasty.

Deep vein thrombosis (DVT) is a major risk following total knee arthroplasty (TKA). This prospective outcomes study evaluates the efficacy of enoxaparin 40 mg once daily for 7 days after TKA, by documenting symptomatic and asymptomatic outcomes using bilateral lower extremity duplex ultrasound upon hospital discharge and on postoperative day 21 (+/-2). In 60 extremities, duplex ultrasound demonstrated a DVT prevalence of 16.7% (10) on the day of discharge and of 11.7% (7) on postoperative day 21. No new DVT or propagation of distal to proximal DVT were noted. For this small cohort, enoxaparin 40 mg daily demonstrates effective prophylaxis for DVT in TKA patients.

Adult↗

The efficacy of continuous bupivacaine infiltration following anterior cruciate ligament reconstruction.

PURPOSE: The purpose of this study was to determine whether continuous infiltration of a local anesthetic into the surgical wound for 48 hours will diminish the need for narcotics and improve the postoperative pain experience for patients undergoing anterior cruciate ligament (ACL) reconstruction using a patellar tendon autograft. TYPE OF STUDY: Prospective, randomized, double-blind study with a placebo and an experimental group. METHODS: Twenty-six patients were randomly assigned to receive either normal saline (placebo) or bupivacaine (experimental) for 48 hours. Both groups received a single intra-articular bolus injection of 35 mL of 0.25% bupivacaine and 5 mg. of morphine at the conclusion of surgery. The placebo group received an infusion of 2 mL/h of normal saline and the experimental group received an infusion of 2 mL/h of 0.25% bupivacaine, both for 48 hours. The anesthetic was infused using a disposable elastomeric pump (Baxter Healthcare, Deerfield, IL). Patients were evaluated using a pain and pain relief assessment questionnaire and visual analogue scale (VAS). Narcotic consumption was also documented. The pump was discontinued either by the patient at home or by a physical therapist. RESULTS: There was a statistically significant (P <.05) difference in VAS pain and pain relief scores reported by patients receiving the infusion of 0.25% bupivacaine. Patients in the treatment group also consumed 37% less narcotics than the placebo group. The operating room time, tourniquet time, weight, and age of this population were similar in the 2 groups. There were no complications with the catheter technique. CONCLUSION: This report of a new technique suggests that surgical knee patients receiving local anesthetic infusion postoperatively experience less pain and require less narcotics. The disposable pump allowed administration of the medication on an outpatient basis.

Adult↗

e-Knee: the electronic knee prosthesis.

Tibiofemoral forces determine polyethylene wear and affect the longevity of total knee prostheses. Previously, investigators relied on theoretic data from mathematical models to predict mechanical forces in the knee. Predictions of tibiofemoral forces are highly variable because of the complex interplay of the muscles involved in activities. Ideally, knee forces should be directly measured. An electronic total knee prosthesis (e-Knee) was developed to directly measure tibiofemoral compressive and tensile forces in vivo. After 13 years of research and development, the e-Knee was implanted into a patient in 2004. Tibiofemoral force data were collected intraoperatively and throughout the postoperative period during activities of daily living and during exercise. Direct measurement of knee forces can lead to a better understanding of the stresses seen following total knee arthroplasty. Information generated by the e-Knee will aid in the improvement of implant design and patient care.

Activities of Daily Living↗