PubMed Health⌕ Search

Biomedical subjects

Panadda Marayong

Publications and source records attributed to Panadda Marayong.

2 recordsLinked to original sources

Speed-accuracy characteristics of human-machine cooperative manipulation using virtual fixtures with variable admittance.

This work explores the effect of virtual fixture admittance on the performance, defined by error and time, of task execution with a human-machine cooperative system. A desired path is obtained using computer vision, and virtual fixtures for assistance in planar path following were implemented on an admittance-controlled robot. The admittance controller uses a velocity gain, so that the speed of the robot is proportional to the force applied by the operator. The level of virtual fixture guidance is determined by the admittance ratio, which is the ratio of the admittance gain of the force components orthogonal to the path to the gain of the force components parallel to the path. In Experiment 1, we found a linear relationship between admittance ratio and performance. In Experiment 2, we examined the effect of admittance ratio on the performance of three tasks: path following, off-path targeting, and obstacle avoidance. An algorithm was developed to select an appropriate admittance ratio based on the nature of the task. Automatic admittance ratio tuning is recommended for next-generation virtual fixtures. Actual or potential applications of this research include surgery, assembly, and manipulation at the macro and micro scales.

Acceleration↗

The effect of visual and haptic feedback on computer-assisted needle insertion.

OBJECTIVE: We present a study evaluating the effects of visual and haptic feedback on human performance in a needle insertion task. MATERIALS AND METHODS: A one-degree-of-freedom needle insertion simulator with a three-layer tissue model (skin, fat and muscle) was used in perceptual experiments. The objective of the 14 subjects was to detect the puncture of each tissue layer using varying haptic and visual cues. Performance was measured by overshoot error-the distance traveled by the virtual needle after puncture. RESULTS: Without force feedback, real-time visual feedback reduced error by at least 87% in comparison to static image overlay. Force feedback, in comparison to no force feedback, reduced puncture overshoot by at least 52% when visual feedback was absent or limited to static image overlay. A combination of force and visual feedback improved performance, especially for tissues with low stiffness, by at least 43% with visual display of the needle position, and by at least 67% with visual display of layer deflection. CONCLUSION: Real-time image overlay significantly enhances controlled puncture during needle insertion. Force feedback may not be necessary except in circumstances where visual feedback is limited.

Adult↗