PubMed Health⌕ Search

Biomedical subjects

Paolo Cardaioli

Publications and source records attributed to Paolo Cardaioli.

At least 19 recordsLinked to original sources

Impact of intracardiac echocardiography on radiation exposure during adult congenital heart disease catheter-based interventions.

BACKGROUND: Intracardiac echocardiography (ICE) is a widespread approach in many cardiovascular procedures in which it has the potential to reduce the fluoroscopy time and patients radiation exposure. We sought to assess the patient radiation exposure during transcatheter closure of interatrial communications with and without ICE-guidance. METHODS: In a prospective consecutive series of 25 consecutive patients who underwent transcatheter closure of interatrial communications between May and October 2005 with (15 patients) and without (10 patients) ICE-guidance in a single secondary care referral centre, we measured the dose-area product (DAP), the fluoroscopy dose-area product (FDAP), the total dose-area product (TDAP), and the mean procedural time. RESULTS: In patients underwent ICE-guided transcatheter closure procedure the mean fluoroscopy time, the mean DAP, mean FDAP, and mean TDAP resulted significantly lower than in control patients: 2.0 +/- 0.21 (range 1.6-2.2) versus 5.05 +/- 0.54 (range 4.2-5.8) minutes (P < 0.001) , 13.72 +/- 9.03 (range 11.36-14.63) versus 21.95 +/- 6.93 (range 20.90-23.93) Gycm2 (P < 0.001), 8.25 +/- 1.22 (range 6.60-9.50) versus 20.15 +/- 8.83 (range 18.90-20.93) Gycm2 (P < 0.001), and 29.33 +/- 1.51(range 27.16-31.00) versus 32.61 +/- 2.53 (range 29.20-35.55) Gycm2 (P < 0.01). On the contrary, the mean procedural time, was significantly higher in ICE-guided transcatheter closure patients: 30.2 +/- 2.45 (range 23-40) versus 24.5 +/- 2.45 (range 24-31) minutes (P = 0.03). CONCLUSION: The radiation exposure during ICE-guided transcatheter closure of interatrial communications in this group of patients was quite lower than that reported in literature for such procedures and compared favourably with radiation exposure of patients in whom the intervention was performed without ICE guidance.

Adult↗

Angiographic long-term follow-up of primary apical ballooning of the left ventricle.

Acute and reversible left ventricular apical wall motion abnormalities presenting with chest pain, electrocardiographic (EKG) changes and cardiac markers release, in the absence of coronary artery stenosis, have already been identified as a possible distinct clinical entity: the so-called Tako-Tsubo syndrome. A 65-year-old man with history of hypertension, hypercholesterolemia and smoking, was admitted at the emergency room of a secondary referral institution with a severe and prolonged (45 min) chest pain, irradiated to the left arm, associated with neurovegetative syndrome. The clinical presentation suggested an acute myocardial infarction (AMI). Interestingly no coronary artery stenoses or vasospasm reaction to administration of acetylcholine could be detected. A slow flow phenomenon was present. The left ventricle angiography confirmed a mild depression of left ventricle systolic function (EF 45%), with akinesia of antero-lateral wall and the typical apical ballooning-like profile. At 3-month follow-up, the patient continued to be asymptomatic and the echocardiogram showed a progressive normalization of left ventricle segmental motion and ejection fraction with a complete restoration only after 6 months. At 1 year the coronary angiography confirmed the absence of coronary stenosis, with complete regression of the ventricular apical ballooning at left ventricle catheterization. At two-year follow-up the patient is still asymptomatic. A slow resolution of the syndrome should be included in the diagnostic criteria for apical ballooning.

Aged↗

Peripheral vascular disease endovascular management in patients scheduled for cardiac surgery: a clinical-angiographic approach.

BACKGROUND: Endovascular management of peripheral vascular disease before cardiac surgery is still debated. We sought to present our preliminary experience of endovascular stent placement in patients scheduled for urgent cardiac surgery. METHODS: Between November 2003 and August 2005, 20 patients scheduled for urgent coronary surgery (13 males, mean age 72.5+/-5.3 years) underwent endovascular repair of PVD on the basis of clinical and angiographic indications. Aspirin (100 mg/day) plus low molecular weight heparin (nadroparin calcium) 100 IU/kg/12 h for urgent coronary surgical revascularization was administered after the procedure. RESULTS: Endovascular stenting has been performed in four clinical settings: renal artery stenting prior to coronary surgery (nine patients) to decrease the impact of extracorporeal circulation on an impaired renal function, iliac artery artery angioplasty and stenting (eight patients) in order to facilitate aortic balloon pump insertion after surgery, subclavian artery angioplasty and stenting propedeutical to arterial conduits bypass surgery (one patient), carotid artery stenting before coronary surgery (two patients). All patients underwent successful endovascular repair followed by cardiac surgery. At a mean follow-up of 12+/-4.6 months all patients are alive and without evident thrombosis or restenosis of the implanted vascular stents. CONCLUSIONS: Endovascular treatment of PVD in patients scheduled for urgent coronary surgery may be effective, relatively safe and lasting in spite of low dose antiplatelet regimen.

Aged↗

Implantation of left ventricular leads using a telescopic catheter system.

BACKGROUND: Implantation procedures for cardiac resynchronization therapy (CRT) remain challenging with regard to coronary sinus (CS) cannulation and left ventricular (LV) lead positioning. Technologic advances in catheter design may facilitate CS cannulation and LV lead placement. AIMS: To evaluate two different telescoping dual-catheter systems, RAPIDO Guiding Catheter System (Group R) and RAPIDO ADVANCE Guiding Catheter System (Group A) (Guidant Inc., St. Paul, MN, USA), during implantation of a CRT device. METHODS: Seventy-four consecutive patients randomly received a CRT device using the R or A system. RESULTS: An LV lead was successfully implanted in 74 patients (100%). (1) Median times for CS cannulation in groups R and A were 0.3 minutes (range from 0.05 to 14 minutes) and 0.5 minutes (range from 0.05 to 9 minutes), respectively (P = NS). (2) Median times for LV lead placement were 8 minutes (range from 0.8 to 100 minutes) and 3.5 minutes (range from 0.25 to 30 minutes), respectively, for groups R and A (P = 0.032). (3) Median total fluoroscopy times were 12.33 minutes (range from 5 to 70 minutes) and 14.33 minutes (range from 6 to 53 minutes) for groups R and A, respectively (P = NS). (4) Median procedural times for CRT implantation were 80 minutes (range from 40 to 200 minutes) and 75 minutes (range from 45 to 180 minutes) (P = NS) in groups R and A, respectively. There were no major complications. CONCLUSION: CS cannulation and LV lead placement with a telescopic dual-catheter system is a safe and feasible approach that may reduce fluoroscopy and overall CRT implantation times. Our observations suggest that the RAPIDO ADVANCE System is faster than the RAPIDO System in terms of median time for LV lead positioning.

Aged↗

Setting up a multidisciplinary program for management of patent foramen ovale-mediated syndromes.

BACKGROUND: These days no codified multidisciplinary protocol has been reported to manage all the different patent foramen ovale (PFO)-mediated syndromes. We sought to propose a multidisciplinary program of diagnosis, treatment, and follow-up of all PFO-mediated syndromes based on an in-hospital multidisciplinary task force and to review the activities during the first year. METHODS: From September 2004, we organized in our hospital, a 600-bed tertiary hospital, a management program for PFO-mediated syndromes based on a task force composed of cardiologists, neurologists, and internists. Different levels of protocols were created in order to cover diagnosis, treatment, and follow-up of PFO-mediated syndromes. We reviewed the activity of our program in the first year up to September 2005. RESULTS: Thirty-five patients (23 female, mean age 65 +/- 24 years) were evaluated for suspected PFO-mediated syndromes: 20 for cryptogenic stroke, 2 for peripheral and coronary embolisms, 3 for platypnea-orthodeoxia, 9 for emicrania with aura, and 1 with hypoxiemia during neurosurgical intervention in the posterior cranial fossa. Diagnosis of PFO was confirmed in 25 patients. According to the multidisciplinary protocols, 15 patients failed to meet the requirements for transcatheter closure and were left in medical therapy whereas 11 patients (7 patients with PFO, 2 with multiperforated ASD, and 2 with a secundum ASD) underwent transcatheter closure. After a mean follow-up of 10.8 +/- 4.9 months, no recurrent PFO syndromes were noted in patients treated with devices. CONCLUSION: The first year of our multidisciplinary program allowed a reasonable and potentially successful approach for correctly identifying patients with PFO-mediated syndromes until randomized studies are completed.

Adult↗

Combined percutaneous aspiration thrombectomy and rheolytic thrombectomy in massive subacute vena cava thrombosis with IVC filter occlusion.

PURPOSE: To report the combined use of percutaneous aspiration thrombectomy and rheolytic thrombectomy in the setting of extensive inferior vena cava (IVC) thrombosis and filter occlusion. CASE REPORT: A 28-year-old paraplegic man with a vena cava filter in situ for previous deep vein thrombosis (DVT) was referred to our center for evaluation of dyspnea and right leg edema and swelling. Computed tomography excluded a pulmonary embolism and revealed severe, massive DVT of both iliac veins and the IVC, including the vena cava filter. Percutaneous aspiration thrombectomy was attempted because intravenous heparin therapy was ineffective, and moderate anemia contraindicated regional thrombolysis. Several passes of a guiding catheter proximally and distally to the filter, with suction provided by a 50-mL syringe, achieved minimal IVC recanalization. Subsequently, a 6-F AngioJet catheter was passed via the guiding catheter through the filter, the IVC, and both iliac veins, obtaining a satisfactory result. The patient was discharged after 7 days and did very well at 6-month follow-up, with no recurrent DVT. CONCLUSION: This case demonstrates the usefulness of combined percutaneous aspiration and rheolytic thrombectomy in treating extensive IVC thrombosis and occluded IVC filters, especially when thrombolytic therapy cannot be used.

Adult↗

Complication with an embolic protection device during carotid angioplasty.

A case of carotid artery stenting with an AngioGuard cerebral protection device is described in a patient with tight internal carotid stenosis. Deployment of AngioGuard induced sudden severe vasospasm, with subsequent minor stroke. According to our observations, AngioGuard may cause a vasospastic response with adverse neurologic effects.

Aged↗

Gender differences in left ventricular function in patients with isolated aortic stenosis.

BACKGROUND AND AIM OF THE STUDY: Hypertrophic response of the left ventricle to systolic overload in aortic stenosis appears to be gender-dependent. METHODS: To examine gender-related differences in left ventricular (LV) function in patients with isolated severe aortic stenosis, 145 patients (65 women, 80 men; mean age 66 +/- 8 years; range: 50 to 89 years) with aortic valve area <0.8 cm2 who underwent cardiac catheterization were studied. No patient had associated myocardial, coronary or other valve disease; patients with diabetes mellitus and systemic hypertension were excluded. RESULTS: No significant differences were seen in aortic valve area between men and women. Neither were there any significant gender-related differences in LV end-systolic and end-diastolic volumes, LV end-diastolic pressure, LV mass indexed by body surface area, LV mass:volume ratio, LV mass:height ratio, elastic stiffness constant, ejection fraction, pulmonary wedge pressure, pulmonary arteriolar resistance and preload. Women showed significantly higher mean transaortic gradient, LV peak systolic pressure and peak systolic stress, end-systolic stress:end-systolic volume ratio, heart rate and cardiac index. In the subgroup of patients with LV pressure >199 mmHg, the mass:volume ratio was increased in men compared with women; of note, the mass:volume ratio in women was not increased in this subgroup compared with the general population. LV pump function in this subgroup was normal and did not differ between men and women. CONCLUSION: Although no clear-cut difference in hemodynamic parameters was seen, there was a trend towards a less compensatory increase in LV mass in females.

Adaptation, Physiological↗

Effect of renal artery stenting on the progression of renovascular renal failure: a case of intravascular ultrasound-confirmed renovascular disease.

We report the case of a 71-year-old male, submitted to percutaneous transluminal renal angioplasty (PTA) plus stent implantation following the confirmation, at intravascular ultrasound, of severe unilateral renal artery stenosis in the setting of a single functional kidney and of evidence of renal insufficiency (serum creatinine value 300 mumol/l). At 6 months of follow-up the serum creatinine levels had returned to normal (98 mumol/l). This case shows the role of direct PTA on the overall renal function in a case of global renal ischemia.

Aged↗

Spontaneous coronary artery dissection mimicking aortic dissection.

A 51-year-old woman suffered rapidly irreversible cardiogenic shock with left hemiparesis. Transesophageal echocardiography, which represents an essential imaging tool in the emergency room, ruled out aortic dissection involving branch vessels but did not allow an in vivo diagnosis of spontaneous coronary dissection. The in vivo diagnosis of spontaneous coronary dissection is rather difficult because of the dramatic clinical presentation and selective coronary angiography requirement.

Aortic Dissection↗