A new application of pre-normalized principal component analysis for improvement of image quality and clinical diagnosis in human brain PET studies--clinical brain studies using [11C]-GR205171, [11C]-L-deuterium-deprenyl, [11C]-5-Hydroxy-L-Tryptophan, [11C]-L-DOPA and Pittsburgh Compound-B.

Principal component analysis (PCA) is one of the most applied multivariate image analysis tool on dynamic Positron Emission Tomography (PET). Independent of used reconstruction methodologies, PET images contain correlation in-between pixels, correlations in-between frame and errors caused by the reconstruction algorithm including different corrections, which can affect the performance of the PCA. In this study, we have investigated a new approach of application of PCA on pre-normalized, dynamic human PET images. A range of different tracers have been used for this purpose to explore the performance of the new method as a way to improve detection and visualization of significant changes in tracer kinetics and to enhance the discrimination between pathological and healthy regions in the brain. We compare the new results with the results obtained using other methods. Images generated using the new approach contain more detailed anatomical information with higher quality, precision and visualization, compared with images generated using other methods.

Antiemetics↗

Multicellular tumour spheroid as a model for evaluation of [18F]FDG as biomarker for breast cancer treatment monitoring.

BACKGROUND: In order to explore a pre-clinical method to evaluate if [18F]FDG is valid for monitoring early response, we investigated the uptake of FDG in Multicellular tumour spheroids (MTS) without and with treatment with five routinely used chemotherapy agents in breast cancer. METHODS: The response to each anticancer treatment was evaluated by measurement of the [18F]FDG uptake and viable volume of the MTSs after 2 and 3 days of treatment. RESULTS: The effect of Paclitaxel and Docetaxel on [18F]FDG uptake per viable volume was more evident in BT474 (up to 55% decrease) than in MCF-7 (up to 25% decrease). Doxorubicin reduced the [18F]FDG uptake per viable volume more noticeable in MCF-7 (25%) than in BT474 MTSs. Tamoxifen reduced the [18F]FDG uptake per viable volume only in MCF-7 at the highest dose of 1 microM. No effect of Imatinib was observed. CONCLUSION: MTS was shown to be appropriate to investigate the potential of FDG-PET for early breast cancer treatment monitoring; the treatment effect can be observed before any tumour size changes occur.The combination of PET radiotracers and image analysis in MTS provides a good model to evaluate the relationship between tumour volume and the uptake of metabolic tracer before and after chemotherapy. This feature could be used for screening and selecting PET-tracers for early assessment of treatment response. In addition, this new method gives a possibility to assess quickly, and in vitro, a good preclinical profile of existing and newly developed anti-cancer drugs.

Journal Article↗

A new, fast and semi-automated size determination method (SASDM) for studying multicellular tumor spheroids.

BACKGROUND: Considering the width and importance of using Multicellular Tumor Spheroids (MTS) in oncology research, size determination of MTSs by an accurate and fast method is essential. In the present study an effective, fast and semi-automated method, SASDM, was developed to determinate the size of MTSs. The method was applied and tested in MTSs of three different cell-lines. Frozen section autoradiography and Hemotoxylin Eosin (H&E) staining was used for further confirmation. RESULTS: SASDM was shown to be effective, user-friendly, and time efficient, and to be more precise than the traditional methods and it was applicable for MTSs of different cell-lines. Furthermore, the results of image analysis showed high correspondence to the results of autoradiography and staining. CONCLUSION: The combination of assessment of metabolic condition and image analysis in MTSs provides a good model to evaluate the effect of various anti-cancer treatments.

Journal Article↗

Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM.

BACKGROUND: Positron Emission Tomography (PET), Computed Tomography (CT), PET/CT and Single Photon Emission Tomography (SPECT) are non-invasive imaging tools used for creating two dimensional (2D) cross section images of three dimensional (3D) objects. PET and SPECT have the potential of providing functional or biochemical information by measuring distribution and kinetics of radiolabelled molecules, whereas CT visualizes X-ray density in tissues in the body. PET/CT provides fused images representing both functional and anatomical information with better precision in localization than PET alone. Images generated by these types of techniques are generally noisy, thereby impairing the imaging potential and affecting the precision in quantitative values derived from the images. It is crucial to explore and understand the properties of noise in these imaging techniques. Here we used autocorrelation function (ACF) specifically to describe noise correlation and its non-isotropic behaviour in experimentally generated images of PET, CT, PET/CT and SPECT. METHODS: Experiments were performed using phantoms with different shapes. In PET and PET/CT studies, data were acquired in 2D acquisition mode and reconstructed by both analytical filter back projection (FBP) and iterative, ordered subsets expectation maximisation (OSEM) methods. In the PET/CT studies, different magnitudes of X-ray dose in the transmission were employed by using different mA settings for the X-ray tube. In the CT studies, data were acquired using different slice thickness with and without applied dose reduction function and the images were reconstructed by FBP. SPECT studies were performed in 2D, reconstructed using FBP and OSEM, using post 3D filtering. ACF images were generated from the primary images, and profiles across the ACF images were used to describe the noise correlation in different directions. The variance of noise across the images was visualised as images and with profiles across these images. RESULTS: The most important finding was that the pattern of noise correlation is rotation symmetric or isotropic, independent of object shape in PET and PET/CT images reconstructed using the iterative method. This is, however, not the case in FBP images when the shape of phantom is not circular. Also CT images reconstructed using FBP show the same non-isotropic pattern independent of slice thickness and utilization of care dose function. SPECT images show an isotropic correlation of the noise independent of object shape or applied reconstruction algorithm. Noise in PET/CT images was identical independent of the applied X-ray dose in the transmission part (CT), indicating that the noise from transmission with the applied doses does not propagate into the PET images showing that the noise from the emission part is dominant. The results indicate that in human studies it is possible to utilize a low dose in transmission part while maintaining the noise behaviour and the quality of the images. CONCLUSION: The combined effect of noise correlation for asymmetric objects and a varying noise variance across the image field significantly complicates the interpretation of the images when statistical methods are used, such as with statistical estimates of precision in average values, use of statistical parametric mapping methods and principal component analysis. Hence it is recommended that iterative reconstruction methods are used for such applications. However, it is possible to calculate the noise analytically in images reconstructed by FBP, while it is not possible to do the same calculation in images reconstructed by iterative methods. Therefore for performing statistical methods of analysis which depend on knowing the noise, FBP would be preferred.

Journal Article↗

Non-isotropic noise correlation in PET data reconstructed by FBP but not by OSEM demonstrated using auto-correlation function.

BACKGROUND: Positron emission tomography (PET) is a powerful imaging technique with the potential of obtaining functional or biochemical information by measuring distribution and kinetics of radiolabelled molecules in a biological system, both in vitro and in vivo. PET images can be used directly or after kinetic modelling to extract quantitative values of a desired physiological, biochemical or pharmacological entity. Because such images are generally noisy, it is essential to understand how noise affects the derived quantitative values. A pre-requisite for this understanding is that the properties of noise such as variance (magnitude) and texture (correlation) are known. METHODS: In this paper we explored the pattern of noise correlation in experimentally generated PET images, with emphasis on the angular dependence of correlation, using the autocorrelation function (ACF). Experimental PET data were acquired in 2D and 3D acquisition mode and reconstructed by analytical filtered back projection (FBP) and iterative ordered subsets expectation maximisation (OSEM) methods. The 3D data was rebinned to a 2D dataset using FOurier REbinning (FORE) followed by 2D reconstruction using either FBP or OSEM. In synthetic images we compared the ACF results with those from covariance matrix. The results were illustrated as 1D profiles and also visualized as 2D ACF images. RESULTS: We found that the autocorrelation images from PET data obtained after FBP were not fully rotationally symmetric or isotropic if the object deviated from a uniform cylindrical radioactivity distribution. In contrast, similar autocorrelation images obtained after OSEM reconstruction were isotropic even when the phantom was not circular. Simulations indicated that the noise autocorrelation is non-isotropic in images created by FBP when the level of noise in projections is angularly variable. Comparison between 1D cross profiles on autocorrelation images obtained by FBP reconstruction and covariance matrices produced almost identical results in a simulation study. CONCLUSION: With asymmetric radioactivity distribution in PET, reconstruction using FBP, in contrast to OSEM, generates images in which the noise correlation is non-isotropic when the noise magnitude is angular dependent, such as in objects with asymmetric radioactivity distribution. In this respect, iterative reconstruction is superior since it creates isotropic noise correlations in the images.

Journal Article↗