PubMed Health⌕ Search

Biomedical subjects

Pat Hanlon

Publications and source records attributed to Pat Hanlon.

2 recordsLinked to original sources

Beat-to-beat effects of intraaortic balloon pump timing on left ventricular performance in patients with low ejection fraction.

BACKGROUND: Intraaortic balloon counterpulsation (IABP) timing errors during arrhythmia may result in afterload increases which may negatively influence left ventricular (LV) ejection and LV mechanical dyssynchrony. The aim of our study was to determine beat-to-beat effects of properly timed IABP, premature IAB inflation, and late IAB deflation on LV performance and LV mechanical dyssynchrony in heart failure patients undergoing cardiac surgery. METHODS: In 15 patients, LV pressure-volume relations and LV dyssynchrony were measured by conductance volume catheter. Properly timed IABP was evaluated at a 1:1 assist ratio within a 10 seconds time-span. Premature IAB inflation and late IAB deflation were evaluated at a 1:4 assist ratio. RESULTS: Properly timed 1:1 IABP acutely decreased LV end-systolic volume by 6.1% (p < 0.0001) and LV end-systolic pressure by 17.5% (p < 0.0001) due to decreased aortic impedance. Stroke volume (SV) increased by 14% (p < 0.0001), which correlated markedly with a decrease of LV mechanical dyssynchrony (p < 0.0001). The largest SV increases occurred in patients with lowest contractile state. Premature IAB inflation decreased SV by 20% (p < 0.0001) due to abrupt increase of LV afterload during late ejection. Late IAB deflation increased SV and stroke work by 18% (p < 0.0001) and 16% (p < 0.01) respectively, due to increased afterload during early ejection and decreased afterload during late ejection. CONCLUSIONS: Left ventricular performance during IABP is causally related to changes in LV afterload, and the timing of these changes in relation to contraction or relaxation phases, to LV mechanical dyssynchrony and to contractile state.

Humans↗

Automatic intraaortic balloon pump timing using an intrabeat dicrotic notch prediction algorithm.

PURPOSE: The efficacy of intraaortic balloon counterpulsation (IABP) during arrhythmic episodes is questionable. A novel algorithm for intrabeat prediction of the dicrotic notch was used for real time IABP inflation timing control. DESCRIPTION: A windkessel model algorithm was used to calculate real-time aortic flow from aortic pressure. The dicrotic notch was predicted using a percentage of calculated peak flow. Automatic inflation timing was set at intrabeat predicted dicrotic notch and was combined with automatic IAB deflation. EVALUATION: Prophylactic IABP was applied in 27 patients with low ejection fraction (< 35%) undergoing cardiac surgery. Analysis of IABP at a 1:4 ratio revealed that IAB inflation occurred at a mean of 0.6 +/- 5 ms from the dicrotic notch. In all patients accurate automatic timing at a 1:1 assist ratio was performed. Seventeen patients had episodes of severe arrhythmia, the novel IABP inflation algorithm accurately assisted 318 of 320 arrhythmic beats at a 1:1 ratio. CONCLUSIONS: The novel real-time intrabeat IABP inflation timing algorithm performed accurately in all patients during both regular rhythms and severe arrhythmia, allowing fully automatic intrabeat IABP timing.

Aged↗