Towards automated, miniaturized and solvent-free sample preparation methods.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Pat Sandra.
Explore the source record for details and available documents.
Polydimethylsiloxane-air partition coefficients (K(PDMS-A)) were determined using direct headspace analysis and headspace sorptive extraction (HSSE) with polydimethylsiloxane-coated (PDMS) stir bars. The partition coefficients were investigated for three compounds, p-dichlorobenzene (PDCB), naphthalene and camphor, all of which sublimate at room temperature and find use as moth repellents. In order to determine the K(PDMS-A) values of these compounds, the air concentration and the concentration present on PDMS, both at equilibrium, were measured. The results indicate that PDMS-air partition coefficients are proportional to octanol-air partition coefficients. Thus, the latter could be used to estimate the extraction efficiency of PDMS for these compounds in air. Alternatively, octanol-air partition coefficients for organic compounds could be estimated from the PDMS-air partition coefficient values. As expected, the PDMS-air (or octanol-air) partition coefficient increased with decreasing temperature. Importantly, the partition coefficients determined at saturated vapor pressures were lower than the values determined at lower analyte concentrations, with the differences being greater for compounds with larger partition coefficients. Consequently, caution should be exercised when applying K(PDMS-A) values determined at high analyte concentrations to measurements at lower concentrations, especially when the partition coefficients are large.
Theoretical aspects of temperature in liquid chromatography (LC) have mostly been studied to elucidate changes in retention behavior of small and large molecules in various solvents. That temperature also plays a significant role in chromatographic performance is less known. Kinetic plots are an established tool to predict chromatographic performance in terms of speed and efficiency that can be obtained with a certain particle size at the maximum attainable column pressure. In this paper, temperature effects on mobile phase viscosity and analyte diffusion are incorporated in these plots to prove that superior performances are within experimental reach for conventional LC columns and equipment. Verification of the modified kinetic plots with experimental data points is presented.
A method based on solid phase extraction (SPE) followed by liquid chromatography-electrospray ionisation tandem mass spectrometry for the determination of the nonapeptides arginine vasotocin (AVT) and isotocin (IT) in brains of three-spined sticklebacks (Gasterosteus aculeatus) is described. Separation and detection were optimized using synthetic standards. Limits of detection (LOD) for standard solutions were 160 pg mL(-1) for AVT and 250 pg mL(-1) for IT. The SPE procedure hardly affected the LODs for standard solutions. Mainly because of ion suppression, LODs for AVT and IT in brains were approximately 5 and 25 pg mg(-1), respectively. The concentrations determined in the brain of several fishes ranged from 10 to 500 pg mg(-1) for AVT and from 400 to 4000 pg mg(-1) for IT.
A practical evaluation of the possibilities and limitations of ultra performance liquid chromatography (UPLC) is presented. Acquity BEH columns packed with 1.7 microm particles are evaluated by means of van Deemter and Knox plots. The columns are characterised by high optimal velocities (3.7 mm/s) and low plate heights (4.4 microm). Minimum plate heights of 2d(p) were, however, not reached and reasons are presented and discussed. Furthermore, the use of 1.7 microm particles at 1000 bar is compared, from a theoretical viewpoint, to conventional LC (3.5 and 5 microm particles at 400 bar) in terms of analysis speed and practical maximum efficiency. Experimental data are used to construct kinetic- or "Poppe-plots", which facilitate investigation of the effect of pressure and particle size on speed and efficiency. It is found that UPLC conditions hold advantages in terms of speed of analysis, for required theoretical plate counts up to approximately 80,000.
A new, empirical approach is introduced to correct for the varying response of aerosol-based detectors with the varying composition of the mobile phase during gradient elution in HPLC. A Corona charged aerosol detector was used in the experiments. The detector is characterized by a nearly universal response at a given, constant mobile-phase composition for sufficiently nonvolatile analytes. A second pump was used to deliver an exactly inverse gradient compared to the analytical HPLC system, and both flows were mixed in a tee piece before introduction to the Corona detector. The approach proposed made it possible to extend the universal response from isocratic to gradient elution conditions in HPLC, vastly improving the usefulness of this detection technique. The constant response of the detector obtained in this way was first demonstrated in flow injection analysis. Very similar calibration curves were obtained for six sulfonamide drugs after mobile-phase compensation. The approach was also applied to gradient elution with excellent results. The data were characterized by good precision ranging from 4% RSD at 10 mg/L to 1.6% RSD at 780 mg/L. The average limit of detection with a 2-microL injection was 0.5 mg/L, corresponding to 1 ng injected on the column. The approach proposed allows quantification of unknown compounds, e.g., in pharmaceutical mixtures. Measurement of analytes at a relative concentration of 0.05% versus the main component is demonstrated.
A simple and fast method for the measurement of 4-hydroxynonenal (4HNE), a highly toxic end-product of lipid peroxidation, in urine samples is described. The method combines stir bar sorptive extraction (SBSE) with two derivatization steps, followed by thermal desorption and GC/MS. 4HNE is derivatized in situ with O-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine and the oxime is extracted from the aqueous phase with SBSE. The 4HNE-oxime is further acylated by headspace derivatization prior to thermal desorption. Derivatization reactions and extraction were optimized in terms of reagent quantities, temperature and time. The method is linear over a concentration range of 0.5-5 ng mL(-1) with a correlation coefficient of 0.997. The limit of detection and limit of quantitation are 22 and 75 pg mL(-1) urine, respectively. The high sensitivity of the method allows the measurement of physiological concentrations of 4HNE in urine samples.
The effects of viscous heat dissipation on some important HPLC parameters, such as efficiency (N) and retention factors (k), using 2.1mm columns at pressures up to 1000 bar have been investigated from both a theoretical and experimental point of view. Two distinct experimental set-ups and their respective influences on non-homogenous temperature gradients within the column are described and discussed. In the first instance, a still-air column heater was used. This set-up leads to approximate 'adiabatic' conditions, and a longitudinal temperature gradient is predicted across the length of the column. The magnitude of this gradient is calculated, and its occurrence confirmed with experimental measurements also indicating that no appreciable loss in efficiency occurs. Secondly, when a water bath is used to thermostat the column, a radial temperature gradient is prevalent. The extent of this gradient is estimated, and the loss in efficiency associated with this gradient is predicted and demonstrated experimentally. It is also observed that approximate adiabatic conditions can lead to floating retention factors. The implications of temperature gradients for routine HPLC analysis at ultra-high pressure are discussed.
High plate numbers were obtained in conventional LC by coupling columns and by using temperature to reduce the viscosity of the mobile phase. At 80 degrees C up to eight columns of 25 cm x 4.6 mm I.D. packed with 5 microm ODS particles could be coupled generating 180,000 effective plates while the pressure drop was only 350bar. For routine work, a set of four columns is preferred. The analysis times on one column operated at 30 degrees C and 1 mL/min flow rate and on four columns at 80 degrees C and 2 mL/min flow rate are the same in isoeluotropic conditions while the resolution is doubled. Multicolumn systems were successfully applied in isocratic and gradient mode for the analysis of pharmaceutical and environmental samples.
A method is described for the analysis of suspected volatile allergens in products containing high molecular weight or non-volatile compounds such as plant extracts, solid and liquid detergents, shampoos, etc. The method is based on dissolution/extraction of the sample followed by direct injection in a programmed temperature vaporizing inlet, the liner of which contains PDMS foam to retain the high molecular weight non-volatile material. The liner is automatically replaced after each injection, by an automated liner exchange device. Analysis is done by GC-MS operated in the retention-time locked mode. The figures of merit are illustrated with the analysis of some real samples.
A low thermal mass column oven was used for fast capillary GC analysis (high throughput) of residual solvents in pharmaceutical products. A dedicated capillary column, 20 m L x 180 microm ID x 1 microm DB-624 was programmed from 35 degrees C (30 s) to 150 degrees C at 100 degrees C/min and to 250 degrees C (30 s) at 200 degrees C/min, resulting in a total GC cycle time of less than 4 min. Complete separation of a target 20-component mixture was achieved, while method performance in terms of repeatability, sensitivity, and linearity was maintained in comparison to the generic method currently applied in our laboratories.
A comprehensive normal phase system LC-reversed phase LC (NPLC x RPLC) was evaluated for the separation of a pharmaceutical mixture and citrus oil extracts. NPLC was performed on a 25 cm x 1 mm ID x 5 microm dp diol phase. In the second dimension, an RP 18 monolithic column (10 cm L x 4.6 mm ID x 2 microm macropore size) and an octadecyl silicagel-packed column (5 cm L x 4.6 mm ID x 3.5 microm dp) were applied for the analyses of the pharmaceutical sample and the citrus oil extracts, respectively. A two-position/ten-port switching valve was used as interface. Under optimised LC conditions, the high degree of orthogonality between NP and RP resulted in peak capacities of 300 for the pharmaceutical sample and of 450 for the citrus oil extract composed of lemon and orange oil. Despite the features of NPLC x RPLC, several shortcomings related with the solvent incompatibility between the two LC modes were identified and the practical consequences were discussed.
Temperature, as a powerful variable in conventional LC is discussed from a fundamental point of view and illustrated with applications from the author's laboratory. Emphasis is given to the influence of temperature on speed, selectivity, efficiency, detectability, and mobile phase composition (green chromatography). The problems accompanying the use of elevated temperature and temperature programming in LC are reviewed and solutions are described. The available stationary phases for high temperature operation are summarized and a brief overview of recent applications reported in the literature is given.
The fields of applicability of headspace sorptive extraction (HSSE) and stir bar sorptive extraction (SBSE) using polydimethylsiloxane (PDMS) as sorbent have been intensively discussed and widely described. One of the limits of sorptive extraction is that PDMS (i.e. an apolar phase) is the only polymer currently in use making it difficult to recover polar analytes from complex or multi-ingredient matrices and those with very volatile components (C1-C4 analytes). Dual-phase twisters are here introduced as new tools for HSSE and SBSE to overcome the above limits. Dual-phase twisters combine the concentration capabilities of two or more sampling materials operating in different ways (in this case sorption and adsorption). The new twisters consist of a short PDMS tube the ends of which are closed with two magnetic stoppers, thus creating an inner cavity that can be packed with different types of adsorbents like activated carbons. The concentration capability of dual-phase twisters was evaluated by using them for the HSSE and SBSE sampling of a number of matrices in the vegetable, food and environmental fields. The contributions made by different carbons to recovery, repeatability and intermediate precision were also investigated.
Temperature was investigated as active parameter in the liquid chromatography (LC) analysis of octylphenol ethoxylates. Significant differences in selectivity were observed when the oligomers were analyzed by reversed phase LC (RPLC) on silica-, zirconia- and polystyrene/divinylbenzene based stationary phases at low (ambient), medium and elevated temperature with acetonitrile/water as mobile phase. As ascertained by LC-mass spectroscopy (MS), in most cases the elution order of the oligomers was completely reversed comparing ambient and high temperature separations. On a graphitized carbon type column, the selectivity remained unchanged, regardless the analysis temperature. Also in normal phase LC, the elution order remained unaffected by temperature variations both for acetonitrile/water and methanol/water mixtures as mobile phase. Surprisingly, when reversed phase LC on a octadecylsilicagel column at different temperatures was repeated with methanol instead of acetonitrile as mobile phase ingredient, the reversal of elution order did not take place. Results are evaluated in terms of thermodynamic parameters.
An automated method for the simultaneous determination of six important organotin compounds namely monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), diphenyltin (DPhT) and triphenyltin (TPhT) in water and sediment samples is described. The method is based on derivatization with sodium tetraethylborate followed by automated headspace-solid-phase micro extraction (SPME) combined with GC-MS under retention time locked (RTL) conditions. Home-synthesized deuterated organotin analogues were used as internal standards. Two high abundant fragment ions corresponding to the main tin isotopes Sn118 and Sn120 were chosen; one for quantification and one as qualifier ion. The method was validated and excellent figures of merit were obtained. Limits of quantification (LOQs) are from 1.3 to 15 ng l(-1) (ppt) for water samples and from 1.0 to 6.3 microg kg(-1) (ppb) for sediment samples. Accuracy for sediment samples was tested on spiked real-life sediment samples and on a reference PACS-2 marine harbor sediment. The developed method was used in a case-study at the harbor of Antwerp where sediment samples in different areas were taken and subsequently screened for TBT contamination. Concentrations ranged from 15 microg kg(-1) in the port of Antwerp up to 43 mg kg(-1) near a ship repair unit.
This study evaluates concentration capability of headspace sorptive extraction (HSSE) and the influence of sampling conditions on HSSE recovery of an analyte. A standard mixture in water of six high-to-medium volatility analytes (isobutyl methyl ketone, 3-hexanol, isoamyl acetate, 1,8-cineole, linalool and carvone) was used to sample the headspace by HSSE with stir bars coated with different polydimethylsiloxane (PDMS) volumes (20, 40, 55 and 110 microL, respectively), headspace vial volumes (8, 21.2, 40, 250 and 1000 mL), sampling temperatures (25, 50 and 75 degrees C) and sampling times (30, 60 and 120 min, and 4, 8 and 16 h). The concentration factors (CFs) of HSSE versus static headspace (S-HS) were also determined. Analytes sampled by the PDMS stir bars were recovered by thermal desorption (TDS) and analysed by capillary GC-MS. This study demonstrates how analyte recovery depends on its physico-chemical characteristics and affinity for PDMS (octanol-water partition coefficients), sampling temperatures (50 degrees C) and times (60 min), the volumes of headspace (40 mL) and of PDMS (in particular, for high volatility analytes). HSSE is also shown to be very effective for trace analysis. The HSSE CFs calculated versus S-HS with a 1000 mL headspace volumes at 25 degrees C during 4 h sampling ranged between 10(3) and 10(4) times for all analytes investigated while the limits of quantitation determined under the same conditions were in the nmol/L range.
A fast method for detection of tuberculostearic acid (TBSA) in sputum samples is described. The samples, obtained from patients with known or suspected pulmonary tuberculosis, were decontaminated and concentrated before being analyzed by stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry (SBSE-TD-GC-MS). Prior to extraction, the mycobacterial lipids were hydrolyzed and then derivatized with ethyl chloroformate to increase the sorption of the compounds by the polydimethylsiloxane (PDMS) stir bar coating. The limit of detection (LOD) is 0.2 ng ml(-1). Four sputum samples that were classified by direct microscopy as smear-positive or negative were analyzed by GC-MS. TBSA was detected at concentrations ranging from 0.47 to 2.3 ng ml(-1). The method is sufficiently sensitive to detect TBSA directly in clinical samples without the need to culture the organisms.