Lung deposition of HFA beclomethasone dipropionate in an animal model of bronchopulmonary dysplasia.

The best delivery of a drug in ventilated neonates is obtained when using a small particle diameter solution administered via a spacer. Lung deposition of hydrofluoroalkane beclomethasone dipropionate (QVAR, 1.3 microm particles), delivered via an Aerochamber-MV15, was measured in piglets under conditions mimicking ventilated severely ill neonates (uncuffed 2.5 mm endotracheal tube; peak pressure 16 cm H2O; respiratory rate 40/min). After determining the mass and particle size distribution of the 99mTc-labeled and unlabeled drug, three lung deposition studies were performed: after 1 h of ventilation (controls, n = 18), after 48 h aggressive ventilation inducing an acute lung injury (nine piglets out of the controls), and after increasing the pressure to 24 cm H2O during drug delivery (five piglets out of the nine with acute lung injury). All piglets were then killed for lung histology. Results (median, range), expressed as a percentage of the delivered dose, were compared using an inferential or the Friedman test. While lung deposition was low, it was greater (p = 0.003) in controls (2.66%, 0.50-7.70) than in piglets with histologically confirmed acute lung injury (0.26%, 0.06-1.28) or under a high-pressure ventilation (1.01%, 0.30-2.15). Lung deposition of QVAR in an animal model of ventilated neonates is low, variable, and dramatically affected by lung injury.

Aerosol Propellants↗

Relationship between ozone and temperature during the 2003 heat wave in France: consequences for health data analysis.

BACKGROUND: PAPRICA is a research program designed to estimate the impact on the health of patients with chronic respiratory insufficiency of a prevention strategy based on notification of ozone pollution. The first year of this study was conducted during the 2003 heat wave, and high temperatures were therefore considered as a confounding factor in the data analysis. The aim of the present study was to assess the relationship between ozone and temperature in order to propose a methodology to distinguish between the effects of ozone and temperature on the impact of a prevention strategy with regard to ozone pollution. METHODS: Multivariate analyses were used to identify associated climate and ozone pollution profiles. This descriptive method is of great value to highlight the complexity of interactions between these parameters. RESULTS: Ozone concentration and temperature were strongly correlated, but the health impact of ozone pollution alone will be evaluated by focusing on situations characterized by ozone concentrations above 110 mug/m3/8h (air quality guidelines to protect human health defined by the French legislation) and temperatures lower than 26 degrees C, below the discomfort threshold. CONCLUSION: The precise relationship between ambient ozone concentration and temperature identified during the PAPRICA 2003 study period will be used in analysing the PAPRICA health data.

Air Pollution↗

New ipratropium formulation to decrease nebulization time.

A new anticholinergic aerosol containing 0.5mg ipratropium bromide dissolved in 1mL of solution has been produced with the purpose of decreasing nebulization time for patients compared to the traditional formulation which is twice as voluminal (0.5mg/2mL, Boehringer-Ingelheim, France). The aim of this study was to compare aerosol characteristics (inhaled mass, particle size distribution and nebulization time) of these two formulations of ipratropium bromide, nebulized alone and with terbutaline (5mg/2mL, Astra Zeneca, Sweden), to determine whether the new formulation was equivalent to the old one. Four different jet nebulizers were used: PariLC+, Atomisor NL9M, Sidestream and Mistyneb. Statistical analysis of the results showed that for all types of nebulizer, the inhaled mass of ipratropium bromide 0.5mg/1mL was significantly lower than the inhaled mass of ipratropium bromide 0.5mg/2mL, and that there was no statistical difference between the inhaled mass of ipratropium bromide 0.5mg/1mL+terbutaline 5mg/2mL and the inhaled mass of ipratropium bromide 0.5mg/2mL+terbutaline 5mg/2mL. The study also showed that the new formulation of ipratropium bromide (0.5mg/1mL) mixed with terbutaline allowed a 26% decrease in nebulization time compared to the old formulation (0.5mg/2mL) mixed with terbutaline without changing aerosol characteristics (inhaled mass and particle size distribution). This leads to the conclusion that a 2mL minimum volume is required for nebulization, and that nebulization of ipratropium bromide 0.5mg/1mL alone must be avoided.

Aerosols↗

EPI-hNE4, a proteolysis-resistant inhibitor of human neutrophil elastase and potential anti-inflammatory drug for treating cystic fibrosis.

EPI-hNE4 (depelstat) is a potent inhibitor of human neutrophil elastase derived from human inter-alpha-trypsin inhibitor and designed to control the excess proteolytic activity in the sputum of cystic fibrosis patients. We analyzed its resistance to the proteolysis it is likely to encounter at inflammatory sites in vivo. EPI-hNE4 resisted hydrolysis by neutrophil matrix metalloproteases (MMPs) and serine proteases that are released from activated neutrophils in inflammatory lung secretions, including MMP-8 and MMP-9, and the elastase-related protease 3 and cathepsin G. It also resisted degradation by epithelial lung cell MMP-7 but was broken down by the Pseudomonas aeruginosa metalloelastase pseudolysin, when used in a purified system, but not when this protease competed with equimolar amounts of neutrophil elastase. We also investigated the inhibitory properties of EPI-hNE4 at the surface of purified blood neutrophils and in the sputum of cystic fibrosis patients where neutrophil elastase is in both a soluble and a gel phase. The elastase at the neutrophil surface was fully inhibited by EPI-hNE4 and formed soluble complexes. The elastase in cystic fibrosis sputum supernatants was inhibited by stoichiometric amounts of EPI-hNE4, allowing titration of the protease. But the percentage of inhibition in whole sputum homogenates varied from 50 to 100%, depending on the sample tested. EPI-hNE4 was rapidly cleaved by the digestive protease pepsin in vitro. Therefore, EPI-hNE4 seems to be an elastase inhibitor suitable for use in aerosols to treat patients with cystic fibrosis.

Adult↗

Gemcitabine aerosol: in vitro antitumor activity and deposition imaging for preclinical safety assessment in baboons.

AIM: To characterize gemcitabine aerosol, its in vitro activity against lung cancer cells, its deposition, and tolerance in a non-human primate model. METHODS: In vitro cytotoxicity of nebulized gemcitabine against NCI-H460 and A549 lung cancer cells was tested using a growth inhibition assay and compared with non-nebulized gemcitabine. The (99m)Tc-DTPA-radiolabeled gemcitabine aerosol was characterized by cascade impaction and the gemcitabine mass/(99m)Tc activity relationship was established for further quantitative nuclear imaging. Nine weekly inhalations at a target dose of 1 mg/kg body weight of gemcitabine were performed in three baboons using dynamic scintigraphic acquisitions for continuous monitoring of gemcitabine delivery during inhalation. Gemcitabine plasma concentrations were measured during the first inhalation. RESULTS: Growth inhibition assays for both NCI-H460 and A549 cells did not differ between nebulized and non-nebulized gemcitabine. Aerosol characterization showed a particle mass median aerodynamic diameter of 3.7+/-0.8 microm and a linear relationship between gemcitabine mass (y) and (99m)Tc activity (x) (y=0.82x - 10(-5), R (2)=0.88). No toxicity was observed after nine weekly inhalations of a mean dose of gemcitabine of 11.1 mg (88% of the target dose) as assessed from scintigraphic data. A dose-dependent peak plasma concentration of gemcitabine (20-74 ng/ml) was observed by the tenth minute of inhalation. CONCLUSIONS: We have characterized a gemcitabine aerosol suitable for intrathoracic airway deposition and demonstrated that jet nebulization does not alter the cytotoxic properties of the drug. In a primate model, we have developed a scintigraphic procedure for the monitoring of aerosol deposition, and we have demonstrated the safety of nine weekly aerosol administrations of gemcitabine.

Aerosols↗

In vitro study and semiempirical model for aerosol delivery control during mechanical ventilation.

The object of this study was to evaluate in vitro the influence of various ventilatory parameters on the delivery of synchronized nebulization of terbutaline during mechanical ventilation and to determine a semiempirical model to control the quantity of aerosol delivered into the patient's lung. An ATOMISOR NL9 M jet nebulizer (La Diffusion Technique Francaise, France) was filled with terbutaline (Bricanyl, Astra-Zeneca, Sweden) and connected to the inspiratory line of a Horus ventilator (Taema, France). Nebulization was synchronized with the inspiratory phase. We assessed at the end of the endotracheal tube the quantity of terbutaline (terbutaline mass output) and the volume median diameter (VMD) by diffraction-laser method. There was a negative correlation between terbutaline mass output and inspiratory air flow ( r =-0.95, p <0.0001) and between VMD and inspiratory air flow ( r =-0.96, p <0.0001). Moreover, positive end-expiratory pressure levels between 0 cm and 8 cm of water did not significantly change the terbutaline output mass ( p =0.22). Total nebulization time and terbutaline mass output calculated by the mathematical model showed good agreement with experimental data. In conclusion, our semiempirical model allows calculation of the duration of the nebulization required to deliver a given mass of terbutaline into patient lungs.

Aerosols↗

Aerosol deposition in neonatal ventilation.

Lung deposition of inhaled drugs in ventilated neonates has been studied in models of questionable relevance. With conventional nebulizers, pulmonary deposition has been limited to 1% of the total dose. The objective of this study was to assess lung delivery of aerosols in a model of neonatal ventilation using a conventional and novel electronic micropump nebulizer. Aerosol deposition studies with 99mTc diethylenetriamine pentaacetate (99mTc-DTPA) were performed in four macaques (2.6 kg) that were ventilated through a 3.0-mm endotracheal tube (with neonatal settings (peak inspiratory pressure 12-14 mbar, positive end-expiratory pressure 2 mbar, I/E ratio 1/2, respiratory rate 40/min), comparing a jet-nebulizer MistyNeb (3-mL charge, 4.8 microm), an electronic micropump nebulizer operating continuously [Aeroneb Professional Nebulizer (APN-C); 0.5-mL charge, 4.6 microm], and another synchronized with inspiration [Aeroneb Professional Nebulizer Synchronized (APN-S); 0.5-mL charge, 2.8 microm]. The amount of radioactivity deposited into lungs and connections and remaining in the nebulizer was measured by a gamma counter. Despite similar amounts of 99mTc-DTPA in the respiratory circuit with all nebulizers, both APN-S and APN-C delivered more drug to the lungs than MistyNeb (14.0, 12.6, and 0.5% in terms of percentage of nebulizer charge, respectively; p = 0.006). Duration of delivery was shorter with APN-C than with the two other nebulizers (2 versus 6 and 10 min for the APN-S and the MistyNeb, respectively; p < 0.001). Electronic micropump nebulizers are more efficient to administer aerosols in an animal model of ventilated neonates. Availability of Aerogen's electronic micropump nebulizers offers new opportunities to study clinical efficacy and risks of aerosol therapy in ventilated neonates.

Administration, Inhalation↗

Safety of pulmonary administration of gemcitabine in rats.

The purpose of this research was to evaluate the safety of pulmonary administration of gemcitabine and to determine the maximum tolerated dose by weekly pulmonary administrations in an animal model. Five groups of eight Wistar rats received gemcitabine at doses of 2, 4, 6, or 8 mg/kg or the vehicle solution by endotracheal spray with scintigraphic imaging of lung deposition. In order to document the safety of digestive exposure, five groups of eight rats received gemcitabine at the same dosages or the vehicle solution by gavage. Nine weekly sessions were planned, and blood cell counts and histological examinations were performed in live animals at day 64. Scintigraphic imaging confirmed pulmonary deposition in 310 of 316 spray administrations (98%) with homogeneous pattern of deposition. The maximum tolerated dose of gemcitabine by pulmonary administration was 4 mg/kg. At this dosage, administered once a week for 9 consecutive weeks, there were no chemotherapy-related deaths and no clinical, histological, or hematological signs of toxicity except for a decrease in platelet and red blood cell counts, with no clinical significance. The toxicity of gemcitabine was higher via oral than lung delivery in terms of weight loss and white blood cell toxicity at dosages of 2, 4, and 6 mg/kg. Pulmonary administration of gemcitabine is safe in rats at a maximum tolerated dose of 4 mg/kg once a week for 9 weeks. At an equivalent dosage, the toxicity of gemcitabine is lower by lung than oral administration.

Administration, Inhalation↗

Relationship between occupational risk factors and severity markers of systemic sclerosis.

OBJECTIVE: To investigate a potential association between occupational risk factors and severity markers of systemic sclerosis (SSc) defined by diffuse cutaneous extent, pulmonary involvement, and immunologic profile, i.e., presence of antitopoisomerase I antibody (anti-topo I). METHODS: Occupational exposures were assessed in 105 patients with SSc from 1998 to 2002. Exposures to silica dust, welding fumes, solvents, and epoxy resins were investigated. A group of 39 exposed SSc patients and a group of 66 unexposed ones were identified and compared according to severity markers of SSc. The stage of cutaneous extent was defined according to the classification of Leroy, as limited scleroderma (lSSc) or diffuse scleroderma (dSSc). Respiratory status was defined by pulmonary function tests and high resolution computed tomography. Immunological profile was determined by the presence of anti-topo I or anticentromere antibodies (ACA). Statistical relationships between occupational exposures and severity markers of SSc were evaluated using a multiple correspondence analysis and Fisher's exact test. RESULTS: Diffuse scleroderma affected mainly patients exposed during their occupational life to toxic agents. There were significant or close to significant associations between toxic exposure and dSSc (p = 0.06), pulmonary involvement (p = 0.10), and negative ACA (p = 0.03). The most incriminated products seemed to be epoxy resins (p = 0.06), white spirit (p = 0.07), aromatic solvents (p = 0.07), and silica coupled to welding fumes (p = 0.10). CONCLUSION: Our results indicate that occupational toxic factors have an influence on the severity of SSc.

Adult↗

Residual gravimetric method to measure nebulizer output.

The aim of this study was to assess a residual gravimetric method based on weighing dry filters to measure the aerosol output of nebulizers. This residual gravimetric method was compared to assay methods based on spectrophotometric measurement of terbutaline (Bricanyl, Astra Zeneca, France), high-performance liquid chromatography (HPLC) measurement of tobramycin (Tobi, Chiron, U.S.A.), and electrochemical measurements of NaF (as defined by the European standard). Two breath-enhanced jet nebulizers, one standard jet nebulizer, and one ultrasonic nebulizer were tested. Output produced by the residual gravimetric method was calculated by weighing the filters both before and after aerosol collection and by filter drying corrected by the proportion of drug contained in total solute mass. Output produced by the electrochemical, spectrophotometric, and HPLC methods was determined after assaying the drug extraction filter. The results demonstrated a strong correlation between the residual gravimetric method (x axis) and assay methods (y axis) in terms of drug mass output (y = 1.00 x -0.02, r(2) = 0.99, n = 27). We conclude that a residual gravimetric method based on dry filters, when validated for a particular agent, is an accurate way of measuring aerosol output.

Aerosols↗