PubMed Health⌕ Search

Biomedical subjects

Patrick A Stone

Publications and source records attributed to Patrick A Stone.

25 records · Page 2Linked to original sources

Angioplasty/stenting of the superior mesenteric artery and celiac trunk: early and late outcomes.

PURPOSE: To analyze the early results and durability of angioplasty/stenting of the superior mesenteric artery (SMA) and celiac trunk (CT). METHODS: Twenty-two patients (19 women; mean age 69.2 years, range 52-88) with 24 symptomatic SMA or CT stenotic lesions were treated with dilation/stenting over a recent 4.5-year period. Two patients had lesions in both the SMA and CT treated. Clinical follow-up and duplex exams were done to evaluate long-term patency. Kaplan-Meier life-table analyses estimated the freedom from recurrent stenosis and recurrent symptoms, as well as survival rates. RESULTS: The initial technical and clinical success rates were 96% (23/24) and 95% (21/22), respectively, with no perioperative mortality or major morbidity. During a mean follow-up of 26 months (range 1-54), the primary late clinical success rate was 61% (11/18; 4 lost to follow-up), and freedom from recurrent stenosis (> or =70%) was 30% (6/20). The freedom from recurrent stenosis at 1, 2, 3, and 4 years were 65%, 47%, 39%, and 13%; freedom from recurrent symptoms was 67% at all 4 intervals. The survival rates were 93%, 93%, 80%, and 53% at 1 to 4 years, respectively. CONCLUSIONS: Angioplasty/stenting of SMA and CT stenoses has a high initial technical success rate and acceptable early and late clinical outcomes; however, it is associated with a high incidence of late restenosis based on strict Doppler criteria.

Aged↗

Early postsurgical carotid restenosis: redo surgery versus angioplasty/stenting.

PURPOSE: To compare the results of balloon angioplasty/stenting (BA/S) versus redo surgery in patients with early carotid restenosis. METHODS: Sixty-one patients (35 women; mean age 69 years, range 46-82) with early restenosis (<24 months from the primary endarterectomy) in 63 carotid arteries were treated during a 5-year period; 41 patients (41 arteries) had redo surgery (group A) and 20 patients (22 arteries) had BA/S (group B). Patients were followed regularly with duplex ultrasound to detect >or=50% recurrent restenosis (RRS) after redo surgery or BA/S. Kaplan-Meier life-table analysis was used to estimate the stroke-free survival rates and freedom from >or=50% RRS. RESULTS: The demographic and clinical characteristics were comparable for both groups, as were the perioperative stroke and death rates (2.4% and 0% for group A, respectively, versus 4.5% and 0% for group B, p=0.46). Group A had a 12% incidence of cranial nerve injury (all transient) versus 0% for group B (p=0.11); however, group B had a higher incidence of >or=50% RRS than group A (32% versus 0%, p=0.0003). The stroke-free survival rates for redo surgery at 6, 12, 24, 36, and 48 months were 100%, 100%, 100%, 100%, and 88% versus 95%, 95%, 84%, 84%, and 63% for BA/S (p=0.067). Redo surgery had a 100% freedom from >or=50% RRS at the same time intervals, while recurrent restenosis rates for the BA/S patients were 95%, 86%, 69%, 52%, and 52% (p<0.0001). CONCLUSIONS: BA/S and redo surgery have comparable stroke and death rates in the treatment of early RCS; however, redo surgery is associated with cranial nerve injuries (transient), while stent patients have a higher incidence of recurrent lesions. These considerations should be kept in mind when selecting the appropriate treatment for patients with early postsurgical restenosis.

Aged↗

Restenting for subclavian in-stent restenosis with symptomatic recurrent coronary-subclavian steal.

PURPOSE: To determine whether restenting for recurrent coronary-subclavian syndrome is technically feasible, provides durable results, and is a reasonable alternative to surgery. CASE REPORT: A 58-year-old woman with a left internal mammary artery (LIMA) bypass to the left anterior descending artery underwent angioplasty and stent placement for left subclavian stenosis and coronary-subclavian steal. Twenty-three months later, she returned with progressive angina and left arm claudication; heart catheterization demonstrated restenosis of the subclavian artery at the stent site with recurrence of the coronary-subclavian steal. Successful redo angioplasty and stenting resulted in normal antegrade flow through the LIMA graft. The patient has remained asymptomatic for 3 years without evidence of recurrent in-stent stenosis on serial noninvasive studies. CONCLUSIONS: Restenting is technically feasible and appears to be a durable response to subclavian in-stent restenosis in patients with coronary subclavian steal.

Angioplasty↗

TrapEase inferior vena cava filter placement: use of the subclavian vein.

The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access and where combined long-term central venous catheter placement using the subclavian vein is desirable.

Adolescent↗

An overview of matrix metalloproteinases in the pathogenesis and treatment of abdominal aortic aneurysms.

Recent basic and clinical research has established a link between the pathogenesis of abdominal aortic aneurysms (AAA) and matrix metalloproteinases (MMP). The discovery of the influence of MMPs on in vitro and in vivo aneurysm development has yielded promising information that may eventually decode the pathogenetic factors affecting the initiation and growth rate of AAAs. In this review, an analysis of MMPs involved in AAA disease is presented, including the data from recent research studies and planned clinical drug trails designed to retard the AAA growth by inhibiting MMP activity.

Animals↗

Femoral pseudoaneurysms.

Iatrogenic pseudoaneurysms will continue to be a problem associated with arterial cannulation procedures. With the increasing trend toward minimally invasive procedures, vascular surgeons, as well as interventionalists will be performing more cannulation procedures; hence we will be more involved in the management of this complication more frequently. Treatment trends and efforts aimed at preventing iatrogenic pseudoaneurysms have evolved over the past decade. This article reviews the history and available literature on the subject, in conjunction with the experience of a center that performs over 10,000 cannulation procedures annually.

Aneurysm, False↗

A rare case of massive gastrointestinal hemorrhage caused by Meckel's diverticulum in a 53-year-old man.

A 53-year-old man with a history of lung cancer mestastic to the brain and pelvis presented with hypotension and massive GI bleeding. He had no past history of gastrointestinal disease or bleeding. The patient was found to have an unusual focal source of bleeding--a large ulcerated Meckel's diverticulum with acute hemorrhage. Meckel's diverticulum is the etiology of most gastrointestinal bleeding episodes in the pediatric population; however, bleeding from a Meckel's diverticulum in an adult is rare and only three other cases have been reported. We present this case report and a literature review.

Gastric Mucosa↗