PubMed Health⌕ Search

Biomedical subjects

Patrick J Geraghty

Publications and source records attributed to Patrick J Geraghty.

14 recordsLinked to original sources

Endovascular repair of thoracic aortic lesions using infrarenal devices: lessons learned and continued applications.

The application of endovascular devices for the treatment of a variety of thoracic aortic lesions has flourished worldwide over the past decade. Until physicians become facile with recently approved thoracic devices and these devices are immediately available even in emergency situations, the use of endovascular abdominal components offers physicians more options in managing thoracic lesions. We evaluated the safety, efficacy, and outcomes of commercially available, infrarenal endovascular graft components for managing lesions of the thoracic aorta. Nineteen patients were treated outside of a clinical trial using commercially available endovascular devices. The indications for treatment included acute traumatic lesions (n = 7), symptomatic ulcers (n = 4), focal aneurysms or pseudoaneurysms (n = 7), and symptomatic type B dissection (n = 1). The endovascular components included Excluder Aortic Cuffs (n = 9), AneuRx Aortic Cuffs (n = 5), Zenith Aortic Cuffs (n = 2), Zenith Aortic Tube Grafts (n = 2), and graft combinations (n = 1). Seventeen patients (89%) underwent successful endovascular treatment of their thoracic lesion. One patient required elective surgical conversion, and a second patient had a dissection that was not completely sealed endovascularly. There was no periprocedural mortality, and the major complication rate was 16% (3/19). Two patients had asymptomatic troponin leaks, and one patient developed an iliac rupture at the device introduction site, hypotension, and paraplegia. At a mean follow-up of 12.3 months, all successfully treated patients continue to have complete exclusion of the treated lesion. Infrarenal endovascular graft components can be very useful in the treatment of selected patients with amenable thoracic lesions until thoracic devices are available in all necessary sizes, readily accessible to treating physicians, and cost-effective.

Adult↗

Minimally invasive approaches to vascular procedures in the elderly.

The incidence of carotid atherosclerosis, aortic aneurysm, and lower extremity ischemia increases with age. Minimally invasive techniques have been proposed to address each of these pathologies. This article compares these newer therapeutic avenues with conventional surgical techniques. Relevant clinical trials are reviewed,with a focus on outcomes beneficial to the elderly population.

Aged↗

Covered stenting of the superficial femoral artery using the Viabahn stent-graft.

High initial technical success rates for superficial femoral artery revascularization are possible using multiple modalities. For these interventions to pose a serious challenge to open surgical bypass, improved primary patency in mid- and long-term follow-up must be achieved. In several smaller studies, covered stenting of the superficial femoral artery has shown superior patency at 2 years after intervention. The ongoing VIBRANT trial randomizes patients to superficial femoral artery intervention with either bare nitinol stents or Viabahn covered stents. The 3-year outcomes data from this trial will better define the role of percutaneous intervention for complex superficial femoral artery disease.

Arterial Occlusive Diseases↗

Aortic neck attachment failure and the AneuRx graft: incidence, treatment options, and early results.

Some investigators have reported that proximal attachment failure is a long-term complication of endovascular abdominal aortic aneurysm repair (EVAR) with the AneuRx (Medtronic, Santa Rosa, CA) device. We evaluated the need for an intervention in patients with suboptimal proximal fixation as well as the feasibility and early success of a variety of treatment strategies. From October 1999 to October 2003, we performed 365 EVARs using the AneuRx graft. At a mean follow-up of 23.7 +/- 14.8 months, 20 patients (5.5%) with suboptimal outcomes (14 with a type I endoleak, one with a type III endoleak, and 5 with an inadequate seal zone <1 cm) were considered for treatment. Characteristics of each patient''s aortic neck anatomy that could be associated with proximal attachment failure were evaluated. Eighteen patients (90%) underwent successful treatment (9 AneuRx cuffs, 6 Talent cuffs, 5 aortic stents, one redo endograft, and two surgical conversions) without major perioperative complications, one patient had a persistent type I endoleak despite endovascular treatment, and one patient refused treatment, ultimately leading to aneurysm rupture. There have been no further endoleaks or graft migrations noted since the secondary intervention at a mean follow-up of 13.9 +/- 11.8 months. In our experience, proximal attachment failure associated with the AneuRx graft is relatively uncommon and usually associated with unfavorable neck anatomy. Despite this, most cases are treatable by endovascular means. Long-term follow-up is needed to assess the ultimate frequency of these combined device reconstructions.

Aged↗

Cardiogenic embolism producing crescendo transient ischemic attacks.

Lateralizing, repetitive transient ischemic attacks are characteristic of symptomatic carotid bifurcation atherosclerotic plaques. We report a case in which a cardiogenic embolus, after lodging at the left carotid bifurcation, produced crescendo episodes of expressive aphasia and mild right upper extremity weakness. Complete neurological recovery was achieved following emergent carotid embolectomy and endarterectomy. This case demonstrates that the laminar nature of internal carotid blood flow may result in the localization of embolic events to a single region of the cerebral vasculature, regardless of the source lesion in the carotid artery. The role of endoluminal techniques in the diagnosis and management of such lesions is discussed.

Aged, 80 and over↗

Acute thromboembolic events during carotid artery angioplasty and stenting: etiology and a technique of neurorescue.

PURPOSE: To review the protected carotid stenting experience at two major referral centers to evaluate the frequency of clinically significant intraprocedural thromboembolic events, use of neurorescue techniques, and ultimate clinical outcomes. METHODS: A retrospective review was conducted of 254 cases of protected transfemoral carotid stenting performed at the Washington University-Barnes Hospital and The Fleni Institute of Buenos Aires in a 6-year period. Medical records of patients with periprocedural thromboembolic events were reviewed to determine the type of complication, method of treatment, and outcome. RESULTS: Among the 254 cases in which a carotid protection device was used, 2 (0.79%) episodes of witnessed, symptomatic thromboembolism occurred. Both patients suffered thromboembolic occlusion of the M1 branch of the middle cerebral artery (MCA) immediately following crossing of the internal carotid lesion with the protection device. Neurological symptoms consisted of agitation, aphasia, and hemiplegia in both patients. After rapid stent deployment across the carotid lesion, the MCA was cannulated and the occlusion treated with balloon angioplasty. This was followed by selective intra-arterial delivery of urokinase and intravenous abciximab. These maneuvers resulted in excellent restoration of blood flow in the MCA and its branches. With the exception of minor word-finding difficulties in one, both patients demonstrated full neurological recovery within the perioperative period. CONCLUSIONS: In our experience, intraprocedural thromboembolic events occur despite the use of cerebral protection devices, but are rare. Notably these complications appeared to occur at the time of lesion crossing by distal cerebral protection devices. These thromboembolic events can be successfully treated if the complication is rapidly identified and the physician is adequately prepared and proficient in neurorescue techniques.

Abciximab↗

Type II endoleak after endovascular abdominal aortic aneurysm repair: a conservative approach with selective intervention is safe and cost-effective.

OBJECTIVES: The conservative versus therapeutic approach to type II endoleak after endovascular repair of abdominal aortic aneurysm (EVAR) has been controversial. The purpose of this study was to evaluate the safety and cost-effectiveness of the conservative approach of embolizing type II endoleak only when persistent for more than 6 months and associated with aneurysm sac growth of 5 mm or more. METHODS: Data for 486 consecutive patients who underwent EVAR were analyzed for incidence and outcome of type II endoleaks. Spiral computed tomography (CT) scans were reviewed, and patient outcome was evaluated at either office visit or telephone contact. Patients with new or late-appearing type II endoleak were evaluated with spiral CT at 6-month intervals to evaluate both persistence of the endoleak and size of the aneurysm sac. Persistent (>or=6 months) type II endoleak and aneurysm sac growth of 5 mm or greater were treated with either translumbar glue or coil embolization of the lumbar source, or transarterial coil embolization of the inferior mesenteric artery. RESULTS: Type II endoleaks were detected in 90 (18.5%) patients. With a mean follow-up of 21.7 +/- 16 months, only 35 (7.2%) patients had type II endoleak that persisted for 6 months or longer. Aneurysm sac enlargement was noted in 5 patients, representing 1% of the total series. All 5 patients underwent successful translumbar sac embolization (n = 4) or transarterial inferior mesenteric artery embolization (n = 4) at a mean follow-up of 18.2 +/- 8.0 months, with no recurrence or aneurysm sac growth. No patient with treated or untreated type II endoleak has had rupture of the aneurysm. The mean global cost for treatment of persistent type II endoleak associated with aneurysm sac growth was US dollars 6695.50 (hospital cost plus physician reimbursement). Treatment in the 30 patients with persistent type II endoleak but no aneurysm sac growth would have represented an additional cost of US dollars 200000 or more. The presence or absence of a type II endoleak did not affect survival (78% vs 73%) at 48 months. CONCLUSIONS: Selective intervention to treat type II endoleak that persists for 6 months and is associated with aneurysm enlargement seems to be both safe and cost-effective. Longer follow-up will determine whether this conservative approach to management of type II endoleak is the standard of care.

Aortic Aneurysm, Abdominal↗

Type II endoleak in porcine model of abdominal aortic aneurysm.

PURPOSE: The purpose of this study was to develop a reliable in vivo porcine model of type II endoleak resulting from endovascular aortic aneurysm repair (EVAR), for the study and treatment of type II endoleak. METHODS: Eight pigs underwent creation of an infrarenal aortic aneurysm, with a Dacron patch with preservation of lumbar branches. An indwelling pressure transducer was placed in the aneurysm sac. After 1 week the animals underwent EVAR with a custom-made Talent endograft. After another week the animals underwent laparoscopic lumbar artery ligation. Abdominal and pelvic computed tomography was performed after each procedure. Aneurysm sac pressure was measured in sedated and awake animals. RESULTS: All eight animals underwent successful creation of an aortic aneurysm and EVAR resulting in exclusion of the aneurysm sac. After creation of the aneurysm the sac mean arterial pressure (MAP) was 72.5 +/- 6.1 mm Hg and the sac pulse pressure was 44.8 +/- 8.7 mm Hg. Postoperative computed tomography scans demonstrated a type II endoleak from the lumbar branches in all animals. While aneurysm sac MAP (56.5 +/- 7.9 mm Hg; P <.01) and pulse pressure (13.6 +/- 4.1 mm Hg; P <.01) decreased after EVAR, sac pulse pressure remained, with type II endoleak. All animals underwent laparoscopic lumbar artery ligation, which resulted in further reduction in the sac MAP (38.3 +/- 4.6 mm Hg; P <.02) and immediate absence of sac pulse pressure (0 mm Hg; P <.01). Necropsy confirmed the absence of collateral flow in the aneurysm sac, with fresh thrombus formation in all animals. CONCLUSION: We present a reliable and clinically relevant in vivo large animal model of type II endoleak. CLINICAL RELEVANCE: We set out to show that aortic aneurysm sac pressurization caused by lumbar arterial flow in the setting of type II endoleak can be reproduced in an in vivo porcine model of endovascular aortic aneurysm repair. Indeed, in this model the aneurysm sac pulse pressure was a sensitive indicator of type II endoleak, correlating well with findings at computed tomography, and lumbar artery ligation eliminated the endoleak, as demonstrated on computed tomography scans and sac pressure measurement. Therefore we believe this in vivo large animal model can be instrumental in the study of many aspects of the physiologic features of type II endoleak.

Angioplasty↗

Overt ischemic colitis after endovascular repair of aortoiliac aneurysms.

OBJECTIVE: Controversy exists as to the cause of ischemic colitis complicating endovascular aneurysm repair. Occlusion of the hypogastric arteries (HAs) during endovascular repair of aortoiliac aneurysms (AIAs) results in a significant incidence of buttock claudication, and has been suggested as a causative factor in the development of postprocedural colonic ischemia, in addition to factors such as systemic hypotension, embolization of atheromatous debris, and interruption of inferior mesenteric artery inflow. To analyze the relationship between perioperative HA occlusion and postoperative ischemic colitis, we reviewed our experience over 2 years with Food and Drug Administration-approved endovascular graft devices for treatment of AIAs. METHODS: Elective repair of AIAs with bifurcated endovascular grafts was performed in 233 patients over a 2-year period. These included 184 AneuRx grafts, 17 Ancure grafts, and 32 Excluder grafts. During the experience, 44 patients (18.9%) underwent unilateral perioperative HA occlusion (28 right, 16 left) during the course of endovascular AIA repair, and 1 patient (0.4%) underwent bilateral HA occlusion. RESULTS: In 4 patients (1.7%) signs and symptoms of ischemic colitis developed 2.0 +/- 1.4 days postoperatively. In all patients the diagnosis was confirmed at sigmoidoscopy, and initial treatment included bowel rest, hydration, and intravenous antibiotic agents. Three patients with bilateral patent HAs required colonic resection 14.7 +/- 9.7 days after the initial diagnosis, and 2 of these 3 patients died in the postoperative period. Pathologic findings confirmed the presence of atheroemboli in the colonic vasculature in all 3 patients who underwent colonic resection. The fourth patient had undergone multiple manipulations of the left HA in an unsuccessful attempt to preserve patency of this vessel during AIA repair. This patient recovered completely with nonoperative management. Perioperative unilateral HA occlusion was not associated with a significantly higher incidence of postoperative ischemic colitis. CONCLUSION: Perioperative HA occlusion during aortoiliac open or endovascular surgery may contribute to development of the rare but potentially lethal complication of ischemic colitis. However, our extensive experience suggests that embolization of atheromatous debris to the HA tissue beds during endovascular manipulations, rather than proximal HA occlusion, is the primary cause of clinically significant ischemic colitis after endovascular aneurysm repair.

Aged↗

Delayed complications after endovascular AAA repair in women.

PURPOSE: To assess whether women suffer more delayed complications or require more interventions after endovascular abdominal aortic aneurysm (AAA) repair. METHODS: Over a 2-year period, 245 patients (203 men, 42 women) underwent endovascular repair with the AneuRx stent-graft at our institution. Baseline, operative, and follow-up data were reviewed and outcomes compared between men and women for complications or secondary procedures beyond the 30-day postoperative period. RESULTS: The 42 (17.1%) women treated with the AneuRx graft experienced more technical complications (17% versus 8.3%; p<0.05) and acute conversions to open repair (6/7, 86%; p=0.0005). At 30 days, systemic morbidity was significantly higher in women (26% versus 5.3%; p=0.001.) However, mortality (2.3% versus 1.5%), length of hospital stay (2.6 versus 2.9 days), and major endoleaks at discharge (0% versus 1.6%) were similar. Over a mean follow-up of 11.3 months (range 1-26), graft limb occlusion occurred more frequently in female patients (12.2% versus 2.5%; p=0.05), and secondary procedures were required in a significantly higher number of women (29% versus 9%; p<0.05). Three patients in each group (25% of women versus 17% of men) who had secondary procedures required additional interventions. Although not statistically significant, the mortality in women during follow-up was higher (9.7% versus 5%); 2 deaths were directly related to graft complications in the female group. CONCLUSIONS: Endoluminal AAA repair in women presents a technical challenge at the time of operation and may cause more frequent late complications, necessitating close postprocedural surveillance and prompt correction of complications to avoid potentially catastrophic outcomes. Reassessment of inclusion criteria for women may be necessary.

Aged↗

Endovascular repair of abdominal aortic aneurysms in women after FDA approval: results, complications, and limitations.

Women account for approximately 25% of patients with AAAs, but unfortunately, only 8-10% of patients considered candidates for endovascular treatment during prospective trials were women. We reviewed our experience with open surgical and endovascular techniques before and after the FDA approval of the Ancure and AneuRx devices to evaluate our results and the role of endovascular treatment of AAAs in women. From January 1999 to August 2000, 269 patients underwent elective repair of their AAAs at our institution. The 20-month period was divided into the 10 months before and after the FDA approval of the endovascular devices for comparison. In the initial time period, 75 patients (62 men and 13 women) underwent repair with 40% undergoing endovascular repair. In the 10 months after FDA approval, 194 patients (160 men and 34 women) underwent repair with 87% undergoing endovascular treatment. Ninety-two percent (155) of the patients undergoing endovascular repair in this period were treated with the AneuRx device. These 155 patients were divided into two groups based on gender to compare their early treatment results. The FDA approval of endovascular grafts has profoundly affected the treatment of infrarenal AAAs in the United States. Women continue to account for a small, but complex, proportion of patients treated with available endovascular devices and the results in these patients is worse than their male counterparts. Careful patient selection and meticulous operative techniques are needed to reliably treat women with available endovascular devices. Further developments are necessary to improve the current results and increase the proportion of women being safely and effectively treated with endovascular devices.

Aged↗

Endovascular repair of traumatic descending thoracic aortic disruptions: should endovascular therapy become the gold standard?

Acute arterial disruptions of the thoracic aorta are rare and often lethal. They are most often due to blunt trauma and occur most commonly just distal to the left subclavian artery origin in the setting of multisystem injuries. The very proximal nature of the lesion in survivors makes open surgical repair hazardous, with mortality rates reaching over 20%. Endovascular therapy is a new and attractive option for the treatment of those challenging patients. Since March 2002, 3 patients with blunt and 1 patient with a stable iatrogenic descending aortic injury were successfully treated at this institution. Spiral computed tomography followed by angiography was used for diagnosis. No preexisting aortic pathology was present. Major associated injuries included unstable thoracic spinal fractures, abdominal solid organ injuries, and hip fractures, making the subjects poor surgical candidates. The Talent Endovascular Graft was deployed via open femoral or iliac artery access under fluoroscopic guidance. All 4 patients underwent successful exclusion of their thoracic pseudoaneurysm with use of the Talent endovascular graft. One patient required partial coverage of the left subclavian artery, and a second patient had an iliac artery stent deployed after traversal of an area of stenosis with the delivery system. There were no cardiac, neurologic, pulmonary, or peripheral vascular complications. Acute aortic disruption, with its associated high surgical morbidity and mortality, is an excellent indication for endovascular therapy to improve patient outcomes. More long-term data are needed on repair durability.

Aged↗