PubMed Health⌕ Search

Biomedical subjects

Patrick O'Leary

Publications and source records attributed to Patrick O'Leary.

3 recordsLinked to original sources

Right ventricular function in asymptomatic individuals with a systemic right ventricle.

BACKGROUND: In congenital heart defects where the morphologic right ventricle (RV) supports the systemic circulation, RV failure is common yet develops gradually. We hypothesized that patients who are asymptomatic may have unrecognized RV dysfunction. METHODS: Conventional and Doppler tissue/strain echocardiography were performed on consecutive patients with asymptomatic systemic RV caused by congenitally corrected transposition of the great arteries (ccTGA) and on age-matched control subjects. RV index of myocardial performance was measured using conventional echocardiography. Longitudinal tissue velocities, strain rate, and strain of the basal RV free wall were measured using Doppler tissue/strain echocardiography and compared with nonsystemic RV of the control subjects. RESULTS: Mean age was 39.5 +/- 14.6 (n = 13) and 36 +/- 24 (n = 10) years for ccTGA and control groups, respectively. Mean RV index of myocardial performance was higher in patients with ccTGA than in control subjects (0.66 +/- 0.25 vs 0.28 +/- 0.12, P < .001). Mean RV tissue displacement (10.8 +/- 4.5 vs 20.3 +/- 3.9 mm, P < .0001), peak systolic strain rate (-1.16 +/- 0.3 vs -2.23 +/- 0.9 s(-1), P = .005), and peak systolic strain (-17.3 +/- 8.0 vs -30.6 +/- 11.0%, P = .008) were significantly lower in patients with ccTGA compared with control subjects, respectively. CONCLUSION: Patients with asymptomatic ccTGA have quantifiable RV dysfunction by echocardiography.

Adult↗

Miniaturized transesophageal echocardiography in newborn infants.

BACKGROUND AND METHODS: A miniaturized 5.5 to 10 MHz, phased-array, single longitudinal plane transducer mounted on a 3.3-mm diameter catheter (miniaturized transesophageal echocardiography [TEE]) may overcome mechanical limitations of standard pediatric transesophageal probes. We evaluated whether the miniaturized TEE probe could define clinically relevant anatomy in 17 infants who weighed less than 6 kg. RESULTS: Twenty-two studies were performed in 17 infants without complication, weighing 2.1 to 5.6 kg. Twenty of twenty-two studies were diagnostic. Pediatric biplane TEE was not possible in 13 studies. Lack of horizontal plane imaging with miniaturized TEE made evaluation difficult in patients with atrioventricular septal defect. CONCLUSION: Miniaturized TEE provided diagnostic intraoperative TEE in the majority of infants studied and may allow broader and safer application of TEE to neonates and small infants.

Cardiac Surgical Procedures↗

Response of Charité total disc replacement under physiologic loads: prosthesis component motion patterns.

BACKGROUND CONTEXT: Total disc replacement (TDR) has been recommended to reduce pain of presumed discogenic origin while preserving spinal motion. The floating core of Charité TDR is professed to allow the replication of the kinematics of a healthy disc under physiologic loads. While segmental motion after Charité TDR has been measured, little is known about the effects of a physiologic compressive preload on vertebral motion and the motion of prosthesis components after TDR. PURPOSE: (1) Does Charité TDR allow restoration of normal load-displacement behavior of a lumbar motion segment under physiologic loads? (2) How do the prosthesis components move relative to each other under physiologic loads when implanted in a lumbar motion segment? STUDY DESIGN: A biomechanical study using human lumbar spines (L1-sacrum). METHODS: Five lumbar spines (age: 52+/-9.3) were used. Specimens were tested under flexion (8 Nm) and extension (6 Nm) moments with compressive follower preloads of 0 N and 400 N in the following sequence: (i) intact, (ii) Charité TDR at L5-S1, (iii) simulated healed fusion at L5-S1 with Charité TDR at L4-L5. Segmental motion was measured optoelectronically. Motions between prosthesis end plates and core were visually assessed using sequential digital video-fluoroscopy over the full range of motion. Here we report on kinematics of 10 Charité TDRs: 5 at L5-S1 and 5 at L4-L5. RESULTS: Charité TDR increased the flexion-extension range of motion of lumbar segments (p<.05). At 400 N preload, the range of motion increased from intact values of 6.8+/-4.4 to 10.0+/-2.4 degrees at L5-S1 and from 7.0+/-2.6 to 10.8+/-2.9 degrees at L4-L5. Charité TDR increased segmental lordosis by 8.1+/-6.9 degrees at L5-S1 (p<.05) and 5.4+/-3.5 degrees at L4-L5 (p<.05). Four patterns of prosthesis component motion were noted: (1) angular motion only between the upper end plate and core, with little or no visual evidence of core translation (9 of 10 TDRs at 0 N preload and 5 of 10 TDRs at 400 N preload); (2) lift-off of upper prosthesis end plate from core or of core from lower end plate (observed in extension in 9 of 10 TDRs under 0 N preload only); (3) core entrapment, resulting in a locked core over a portion of the range of motion (observed in extension in 8 of 10 TDRs under 400 N preload); (4) angular motion between both the upper and lower end plates and core, with visual evidence of core translation (1 of 10 TDRs at 0 N preload, 5 of 10 TDRs at 400 N preload). The pattern of load-displacement curves was substantially changed under a physiologic preload in 8 of 10 TDRs; instead of a relatively gradual change in angle with changing moment application as seen for an intact segment, the TDR displayed regions of both relatively small and relatively large angular changes with gradual moment application. CONCLUSIONS: Charité TDR restored near normal quantity of flexion-extension range of motion under a constant physiologic preload; however, the quality of segmental motion differed from the intact case over the flexion-extension range. Whereas some TDRs showed visual evidence of core translation, the predominant angular motion within the prosthesis occurred between the upper end plate and the polyethylene core. Likely factors affecting the function of the Charité TDR include implant placement and orientation, intraoperative change in lordosis, and magnitude of physiologic compressive preload. Further work is needed to assess the effects of the prosthesis motion patterns identified in the study on the load sharing at the implanted level and polyethylene core wear.

Aged↗