PubMed Health⌕ Search

Biomedical subjects

Patrick W Serruys

Publications and source records attributed to Patrick W Serruys.

At least 19 recordsLinked to original sources

Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases.

BACKGROUND: We describe the clinical and morphological patterns of restenosis after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS: From 121 patients with coronary angiography obtained >30 days after SES implantation, restenosis (diameter stenosis >50%) was identified in 19 patients and 20 lesions (located at the proximal 5-mm segment in 30% or within the stent in 70%). Residual dissection after the procedure or balloon trauma outside the stent was identified in 83% of the proximal edge lesions. Lesions within the stent were focal, and stent discontinuity was identified in some lesions evaluated by intravascular ultrasound. CONCLUSIONS: Sirolimus-eluting stent edge restenosis is frequently associated with local trauma outside the stent. In-stent restenosis occurs as a localized lesion, commonly associated with a discontinuity in stent coverage. Local conditions instead of intrinsic drug-resistance to sirolimus are likely to play a major role in post-SES restenosis.

Adult↗

Extension of increased atherosclerotic wall thickness into high shear stress regions is associated with loss of compensatory remodeling.

BACKGROUND: Atherosclerosis preferentially develops at average low shear stress (SS) locations. SS-related signaling maintains lumen dimensions by inducing outward arterial remodeling. Prolonged plaque accumulation at low SS predilection locations explains an inverse relation between wall thickness (WT) and SS. No data exist on WT-SS relations when lumen narrowing and loss of compensatory remodeling commence. METHODS AND RESULTS: In 14 patients, an angiographically normal artery (stenosis <50%) was investigated with ANGiography and ivUS (ANGUS) to provide 3D lumen and wall geometry. Selection of segments >5 mm in length, in between side branches, yielded 25 segments in 12 patients. SS at the wall was calculated by computational fluid dynamics. WT smaller than 0.2*lumen diameter was defined as normal. Largest arc of normal WT defined reference cross sections. Lumen area relative to the reference cross sections defined area stenosis (AS). Average segmental AS smaller or greater than 10% defined preserved or narrowed lumen, respectively. Total vessel area relative to the reference defined vascular remodeling (VR). For the preserved lumens (n=11, AS=1.7+/-5.6%, P=NS), axially averaged WT and SS were inversely related (slope, -0.46+/-0.55 mm/Pa, P<0.05) and VR was positive (7+/-9%, P<0.05). Narrowed segments (n=13, 1 excluded, AS=18+/-6%, P<0.05) showed no relation between WT and SS or vascular remodeling. CONCLUSIONS: In patient coronary arteries, the often-reported inverse WT-SS relationship appears restricted to lumen preservation and positive vascular remodeling. Its disappearance with lumen narrowing suggests a growing importance of non-SS-related plaque progression.

Age Factors↗

Early outcome after sirolimus-eluting stent implantation in patients with acute coronary syndromes: insights from the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry.

OBJECTIVES: This study evaluated the early outcomes of patients with acute coronary syndromes (ACS) treated with sirolimus-eluting stents (SES). BACKGROUND: The safety of SES implantation in patients with a high risk for early thrombotic complications is currently unknown. METHODS: Sirolimus-eluting stents have been utilized as the device of choice for all percutaneous procedures in our institution, as part of the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry. After four months of enrollment, 198 patients with ACS had been treated exclusively with SES (64% of those treated in the period) and were compared with a control group composed of 301 consecutive patients treated with bare stents in the same time period immediately before this study. The incidence of major adverse cardiac events (MACE) during the first month was evaluated (death, nonfatal myocardial infarction [MI], or re-intervention). RESULTS: Compared with control patients, patients treated with SES had more primary angioplasty (95% vs. 77%; p < 0.01), more bifurcation stenting (13% vs. 5%; p < 0.01), less previous MI (28% vs. 45%; p < 0.01), and less glycoprotein IIb/IIIa inhibitor utilization (27% vs. 42%; p < 0.01). The 30-day MACE rate was similar between both groups (SES 6.1% vs. control patients 6.6%; p = 0.8), with most complications occurring during the first week. Stent thrombosis occurred in 0.5% of SES patients and in 1.7% of control patients (p = 0.4). In multivariate analysis, SES utilization did not influence the incidence of MACE (odds ratio 1.0 [95% confidence interval: 0.4 to 2.2]; p = 0.97). CONCLUSIONS: Sirolimus-eluting stent implantation for patients with ACS is safe, with early outcomes comparable with bare metal stents.

Acute Disease↗

Augmentation of wall shear stress inhibits neointimal hyperplasia after stent implantation: inhibition through reduction of inflammation?

BACKGROUND: Low wall shear stress (WSS) increases neointimal hyperplasia (NH) in vein grafts and stents. We studied the causal relationship between WSS and NH formation in stents by locally increasing WSS with a flow divider (Anti-Restenotic Diffuser, Endoart SA) placed in the center of the stent. METHODS AND RESULTS: In 9 rabbits fed a high-cholesterol diet for 2 months to induce endothelial dysfunction, 18 stents were implanted in the right and left external iliac arteries (1 stent per vessel). Lumen diameters were measured by quantitative angiography before and after implantation and at 4-week follow-up, at which time, macrophage accumulation and interruption of the internal elastic lamina was determined. Cross sections of stent segments within the ARED (S+ARED), outside the ARED (S[minus]ARED), and in corresponding segments of the contralateral control stent (SCTRL) were analyzed. Changes in WSS induced by the ARED placement were derived by computational fluid dynamics. Computational fluid dynamics analysis demonstrated that WSS increased from 0.38 to 0.82 N/m2 in the S+ARED immediately after ARED placement. This augmentation of shear stress was accompanied by (1) lower mean late luminal loss by quantitative angiography ([minus]0.23+/-0.22 versus [minus]0.58+/-0.30 mm, P=0.02), (2) reduction in NH (1.48+/-0.58, 2.46+/-1.25, and 2.36+/-1.13 mm2, P<0.01, respectively, for S+ARED, S[minus]ARED, and SCTRL), and (3) a reduced inflammation score and a reduced injury score. Increments in shear stress did not change the relationship between injury score and NH or between inflammation score and NH. CONCLUSIONS: The newly developed ARED flow divider significantly increases WSS, and this local increment in WSS is accompanied by a local reduction in NH and a local reduction in inflammation and injury. The present study is therefore the first to provide direct evidence for an important modulating role of shear stress in in-stent neointimal hyperplasia.

Animals↗

Evaluation of coronary remodeling after sirolimus-eluting stent implantation by serial three-dimensional intravascular ultrasound.

This study evaluates the response of the coronary vessel wall to implantation of the sirolimus-eluting stent (SES), Bx-VELOCITY, by using serial intravascular ultrasound. SESs have a major impact on the inhibition of in-stent neointimal hyperplasia. However, changes in the vessel wall and behind stent struts in animal models and humans have not been evaluated after SES implantation. Thirty-four patients who received a SES (n = 24) or a Bx-VELOCITY bare stent (BS) (n = 10) for single de novo coronary lesions and had serial motorized pullback 3-dimensional intravascular ultrasound were included. Stent, lumen, and vessel volumes were similar in the 2 groups at baseline. At follow-up, significantly larger lumen and lower neointimal hyperplasia volumes (0.7 vs 33 mm(3), p = 0.001) were seen in the SES group compared with the BS group. There was no significant difference between SES and BS in either the vessel volume (+2.4% vs +0.7%, p = NS) or the plaque behind stent volume change (+3.4% vs +2.5%, p = NS) from after the procedure to late follow-up. The stent edges also showed no significant difference between postprocedural and follow-up measurements, either in patients receiving SESs or BSs. No stented or edge segment required redilatation in the SES group, whereas 2 patients underwent repeat percutaneous coronary angioplasty in the BS group. In the SES group, 1 patient (4%) showed late acquired incomplete stent apposition. Thus, the SES is effective in inhibiting neointimal hyperplasia without affecting vessel volume and plaque behind the stent.

Angioplasty, Balloon, Coronary↗

TAXUS III Trial: in-stent restenosis treated with stent-based delivery of paclitaxel incorporated in a slow-release polymer formulation.

BACKGROUND: The first clinical study of paclitaxel-eluting stent for de novo lesions showed promising results. We performed the TAXUS III trial to evaluate the feasibility and safety of paclitaxel-eluting stent for the treatment of in-stent restenosis (ISR). METHODS AND RESULTS: The TAXUS III trial was a single-arm, 2-center study that enrolled 28 patients with ISR meeting the criteria of lesion length < or =30 mm, 50% to 99% diameter stenosis, and vessel diameter 3.0 to 3.5 mm. They were treated with one or more TAXUS NIRx paclitaxel-eluting stents. Twenty-five patients completed the angiographic follow-up at 6 months, and 17 of these underwent intravascular ultrasound (IVUS) examination. No subacute stent thrombosis occurred up to 12 months, but there was one late chronic total occlusion, and additional 3 patients showed angiographic restenosis. The mean late loss was 0.54 mm, with neointimal hyperplasia volume of 20.3 mm3. The major adverse cardiac event rate was 29% (8 patients; 1 non-Q-wave myocardial infarction, 1 coronary artery bypass grafting, and 6 target lesion revascularization [TLR]). Of the patients with TLR, 1 had restenosis in a bare stent implanted for edge dissection and 2 had restenosis in a gap between 2 paclitaxel-eluting stents. Two patients without angiographic restenosis underwent TLR as a result of the IVUS assessment at follow-up (1 incomplete apposition and 1 insufficient expansion of the stent). CONCLUSIONS: Paclitaxel-eluting stent implantation is considered safe and potentially efficacious in the treatment of ISR. IVUS guidance to ensure good stent deployment with complete coverage of target lesion may reduce reintervention.

Antineoplastic Agents, Phytogenic↗

Two-year angiographic and intravascular ultrasound follow-up after implantation of sirolimus-eluting stents in human coronary arteries.

BACKGROUND: The safety and efficacy of sirolimus-eluting stenting have been demonstrated, but the outcome of patients treated with this novel technology beyond the first year remains unknown. We sought to evaluate the angiographic, intravascular ultrasound (IVUS), and clinical outcomes of patients treated with sirolimus-eluting stents 2 years after implantation. METHODS AND RESULTS: This study included 30 patients treated with sirolimus-eluting Bx Velocity stenting (slow release [SR], n=15, and fast release [FR], n=15) in São Paulo, Brazil. Twenty-eight patients underwent 2-year angiographic and IVUS follow-up. No deaths occurred during the study period. In-stent late loss was slightly greater in the FR group (0.28+/-0.4 mm) than in the SR group (-0.09+/-0.23 mm, P=0.007). No patient had in-stent restenosis. At 2-year follow-up, only 1 patient (FR group) had a 52% diameter stenosis within the lesion segment, which required repeat revascularization. The target-vessel revascularization rate for the entire cohort was 10% (3/30) at 2 years. All other patients had < or =35% diameter stenosis. Angiographic lumen loss at the stent edges was also minimal (in-lesion late loss was 0.33+/-0.42 mm [FR] and 0.13+/-0.29 mm [SR]). In-stent neointimal hyperplasia volume, as detected by IVUS, remained minimal after 2 years (FR= 9.90+/-9 mm3 and SR=10.35+/-9.3 mm3). CONCLUSIONS: This study demonstrates the safety and efficacy of sirolimus-eluting Bx Velocity stents 2 years after implantation in humans. In-stent lumen dimensions remained essentially unchanged at 2-year follow-up in the 2 groups, although angiographic lumen loss was slightly higher in the FR group. Restenosis "catch-up" was not found in our patient population.

Combined Modality Therapy↗

Sirolimus-eluting stent for treatment of complex in-stent restenosis: the first clinical experience.

OBJECTIVES: In this study, we assess the value of sirolimus eluting stent (SES) implantation in patients with complex in-stent restenosis (ISR). BACKGROUND: The treatment of ISR remains a therapeutic challenge, since many pharmacological and mechanical approaches have shown disappointing results. The SESs have been reported to be effective in de-novo coronary lesions. METHODS: Sixteen patients with severe, recurrent ISR in a native coronary artery (average lesion length 18.4 mm) and objective evidence of ischemia were included. They received one or more 18 mm Bx VELOCITY SESs (Cordis Waterloo, Belgium). Quantitative angiographic and three-dimensional intravascular ultrasound (IVUS) follow-up was performed at four months, and clinical follow-up at nine months. RESULTS: The SES implantation (n = 26) was successful in all 16 patients. Four patients had recurrent restenosis following brachytherapy, and three patients had totally occluded vessels preprocedure. At four months follow-up, one patient had died and three patients had angiographic evidence of restenosis (one in-stent and two in-lesion). In-stent late lumen loss averaged 0.21 mm and the volume obstruction of the stent by IVUS was 1.1%. At nine months clinical follow-up, three patients had experienced four major adverse cardiac events (two deaths and one acute myocardial infarction necessitating repeat target vessel angioplasty). CONCLUSIONS: The SES implantation in patients with severe ISR lesions effectively prevents neointima formation and recurrent restenosis at four months angiographic follow-up.

Adult↗

Sirolimus-eluting stent for the treatment of in-stent restenosis: a quantitative coronary angiography and three-dimensional intravascular ultrasound study.

BACKGROUND: We have previously reported the safety and effectiveness of sirolimus-eluting stents for the treatment of de novo coronary lesions. The present investigation explored the potential of this technology to treat in-stent restenosis. METHODS AND RESULTS: Twenty-five patients with in-stent restenosis were successfully treated with the implantation of 1 or 2 sirolimus-eluting Bx VELOCITY stents in São Paulo, Brazil. Nine patients received 2 stents (1.4 stents per lesion). Angiographic and volumetric intravascular ultrasound (IVUS) images were obtained after the procedure and at 4 and 12 months. All vessels were patent at the time of 12-month angiography. Angiographic late loss averaged 0.07+/-0.2 mm in-stent and -0.05+/-0.3 mm in-lesion at 4 months, and 0.36+/-0.46 mm in-stent and 0.16+/-0.42 mm in-lesion after 12 months. No patient had in-stent or stent margin restenosis at 4 months, and only one patient developed in-stent restenosis at 1-year follow-up. Intimal hyperplasia by 3-dimensional IVUS was 0.92+/-1.9 mm(3) at 4 months and 2.55+/-4.9 mm(3) after 1 year. Percent volume obstruction was 0.81+/-1.7% and 1.76+/-3.4% at the 4- and 12-month follow-up, respectively. There was no evidence of stent malapposition either acutely or in the follow-up IVUS images, and there were no deaths, stent thromboses, or repeat revascularizations. CONCLUSION: This study demonstrates the safety and the potential utility of sirolimus-eluting Bx VELOCITY stents for the treatment of in-stent restenosis.

Combined Modality Therapy↗