PubMed Health⌕ Search

Biomedical subjects

Patrik Petersson

Publications and source records attributed to Patrik Petersson.

9 recordsLinked to original sources

Nanoparticle-based continuous full filling capillary electrochromatography/electrospray ionization-mass spectrometry for separation of neutral compounds.

Highly efficient reversed-phase capillary electrochromatography (CEC) separations (plate numbers up to 700 000/m), with electrospray ionization mass spectrometry detection were achieved utilizing novel dextran-coated polymer nanoparticles as a pseudostationary phase. A continuous full filling (CFF) technique in which nanoparticles are continuously introduced into the capillary was employed for separation of neutral analytes (dialkyl phthalates), utilizing an orthogonal electrospray interface to prevent nanoparticles from entering the mass spectrometer. CFF-CEC benefits from that an entirely fresh column is employed for every analysis, avoiding carryover effects associated with stationary-phase contamination. The highly efficient separations obtained were accomplished by optimizing the organic modifier concentration in the electrolyte and by using a high nanoparticle concentration (5 mg/mL), to improve interparticle mass transfer and gain sufficient retention. Nanoparticles, with an average diameter of 600 nm, were prepared by polymerization of methacrylic acid and trimethylolpropane trimethacrylate, which in turn were coated with dextran. These nanoparticles formed stable suspensions in electrolytes having broad ranges of polarities, enabling straightforward optimization of the reversed-phase conditions.

Capillary Electrochromatography↗

An observation of unusual temperature effects for enantioselective CZE employing highly sulfated-beta-cyclodextrin.

In this paper data are presented suggesting that for enantiomers of basic and neutral analytes, the concentrations of highly sulfated CDs typically used are above the optimum since lower concentrations result in unacceptable migration times. This situation arises because of the high binding affinities often obtained with sulphated CDs. In a system being over the optimum CD concentration increasing the temperature of the capillary offers a capability to improve selectivity and reduce migration times.

Electrophoresis, Capillary↗

Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns containing polar embedded groups/amino endcappings using principal component analysis.

Polar embedded phases have become increasingly popular in liquid chromatography (LC) analysis. These phases can produce diverse chromatographic selectivities as a result of their differing base silica, the type of polar embedded group (i.e. amide, urea, carbamate, ether or sulphonamide moieties) and the length of the alkyl ligand. Four column characterization protocols, using differing test probes, have been used to characterize 18 of these phases together with 17 alkyl phases (some of which contained novel polar endcapping, i.e. amino), which have been evaluated using principal component analysis (PCA). PCA provided graphical comparisons of the differences/similarities between these phases and between their corresponding C-alkyl, amino endcapped and enhanced polar selectivity phases.

Amines↗

An evaluation of the robustness of the Tanaka characterization protocol for reversed-phase liquid chromatography columns.

The robustness of the popular 'Tanaka' LC column characterization protocol has been evaluated by the statistical tools of reduced factorial design, multiple linear regression and principal component analysis. These have shown that in order to obtain reliable and reproducible results, it is especially important to control the methanol content, the temperature and, in the case of the total ion-exchange capacity test (alphaB/P pH 7.6), the pH of the mobile phase. In particular, the hydrophobicity tests (kPB and alphaCH2) are sensitive to small changes in methanol content. Provided that the operating parameters for the Tanaka column characterization protocol are controlled within the following experimental limits, i.e. methanol content +/-0.5% v/v, temperature +/-3degreesC, pH +/-0.10 and buffer concentration +/-2.0 mM, it is feasible to distinguish between RP materials that possess selectivity differences larger than their batch-to-batch reproducibility. These experimental requirements can be easily met by current LC instrumentation. Hence, the validity of the Tanaka testing protocol for characterizing columns has been verified.

Benzene Derivatives↗

A chemometric study of active parameters and their interaction effects in a nebulized sheath-liquid electrospray interface for capillary electrophoresis-mass spectrometry.

A chemometrics approach has been used for evaluating the effect of four experimental parameters when coupling capillary electrophoresis (CE) to electrospray ionization-mass spectrometry (ESI-MS). Electrospray voltage, sheath-liquid flow rate, nebulizing gas flow rate, and spray needle position in respect to the MS orifice were varied according to a full factorial design. In addition to main effects, two interaction effects could be identified as significant when measuring the peak intensity of the analytes, from a sample mixture containing peptides and pharmaceuticals. The first interaction effects, between the nebulizing gas flow rate and the sheath-liquid flow rate, and the second interaction effect, between the nebulizing gas flow rate and the spray position, could further explain the impact that these variables have on the spray performance. The number of theoretical plates and the baseline noise were also measured. The sheath-liquid flow was found to significantly affect the separation efficiency, while the noise level mainly was controlled by the nebulizing gas flow. The same factorial design was also used for a CE capillary with lower internal diameter (ID) and the effects of the same variables were compared on those capillaries using equal injection volume for both capillaries. Similar trends were obtained in both capillaries but capillary ID was shown to be a significant variable when evaluating both capillaries in a single model. It was found that a capillary with 25 microm ID provided improved CE-MS performance over than corresponding 50 microm ID capillary. Enhanced sensitivity was obtained using the narrow-bore capillary, and at lower sheath-liquid flow rate the 25 microm ID capillary also gave rise to more efficient peaks.

Electrophoresis, Capillary↗

Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns using principal component analysis.

A total of 135 commercially available alkyl, cyano, phenyl, perfluorinated, polar embedded, enhanced polar selectivity (i.e., polar/hydrophilic endcapped), "Aqua type" and a variety of novel phases including some non-silica based stationary phases have been characterised in terms of their surface coverage, hydrophobic selectivity, shape selectivity, hydrogen bonding capacity and ion-exchange capacity at pH 2.7 and 7.6. Principal component analysis has been used to provide a simple graphical comparison of the differences/similarities between columns in the entire database and differing subsets such as "Aqua type"/enhanced polar selectivity phases. The PCA has been correlated to the phase's ability to analyse a range of hydrophilic bases.

Chromatography, Liquid↗

Direct coupling of micellar electrokinetic chromatography to mass spectrometry using a volatile buffer system based on perfluorooctanoic acid and ammonia.

Direct coupling of micellar electrokinetic chromatography (MEKC) to mass spectrometry (MS) without employing partial filling is considered to be a challenge. One way of solving the problem would be the use of an MS-compatible surfactant. In the present study, the applicability of a series of surfactants (sodium dodecyl sulfate (SDS), lauric acid, cholic acid and perfluorated carboxylic acids) have been investigated both in terms of separation performance and MS compatibility. It was found that a MEKC system based on perfluorooctanoic acid (PFOA) and ammonia gave excellent results. The separation performance of the suggested system is comparable to the one obtained with standard systems based on SDS and sodium borate buffer although the selectivity is different. The electrospray ionization MS signal of the analytes is not seriously suppressed even at a PFOA concentration of 100 mM. Clusters are formed but their intensities are relatively low and comparable to those obtained with acetic acid. PFOA is volatile enough to allow long-term use, 30 h of continuous use has been recorded without any signs of decreasing performance. After use residual PFOA is easily removed from the ion-source (no memory effects). Furthermore, quantitation of trace impurities is possible at 25 ppb level when employing selected ion monitoring.

Ammonia↗

Copolymeric (lR-trans)-N,N'-1,2-cyclohexylene-bisbenzamide oligodimethylsiloxane chiral stationary phase for gas chromatography.

A copolymeric stationary phase, consisting of a chiral selective part, i.e. (1R-trans)-N,N'-1,2-cyclohexylenebisbenzamide, and an efficient siloxane oligomeric part, was successfully applied to open tubular column GC analysis. The efficiency and the chiral selectivity of this stationary phase were studied in detail, and high capacity and efficiency at elevated GC temperatures were especially noted. Several drugs and other enantiomeric pairs were separated. The shown examples demonstrate a broad application range for this type of chiral stationary phase in GC analysis.

Benzamides↗

Nanoparticles as pseudostationary phase in capillary electrochromatography/ESI-MS.

A novel technique that uses polymer nanoparticles as pseudostationary phase in capillary electrochromatography with electrospray ionization mass spectrometry detection is described. A continuous full filling technique in which the nanoparticles were suspended in the entire electrolyte volume as well as a conventional partial filling technique is presented. No nanoparticles entered the mass spectrometer, which was fitted with an orthogonal electrospray interface, despite the continuous flow of nanoparticles into the interface. Nanoparticles (average diameter 160 nm) were prepared from methacrylic acid, methyl methacrylate, and trimethylolpropane trimethacrylate by utilizing a precipitation polymerization technique. Salbutamol, nortriptyline, and diphenhydramine were used as analytes. The interaction between analytes and nanoparticles was found to be predominantly ionic.

Journal Article↗