Guidelines for preventing the transmission of Mycobacterium tuberculosis in health-care settings, 2005.

In 1994, CDC published the Guidelines for Preventing the Transmission of Mycobacterium tuberculosis in HealthCare Facilities, 1994. The guidelines were issued in response to 1) a resurgence of tuberculosis (TB) disease that occurred in the United States in the mid-1980s and early 1990s, 2) the documentation of several high-profile health-care--associated (previously termed "nosocomial") outbreaks related to an increase in the prevalence of TB disease and human immunodeficiency virus (HIV) coinfection, 3) lapses in infection control practices, 4) delays in the diagnosis and treatment of persons with infectious TB disease, and 5) the appearance and transmission of multidrug-resistant (MDR) TB strains. The 1994 guidelines, which followed statements issued in 1982 and 1990, presented recommendations for TB infection control based on a risk assessment process that classified health-care facilities according to categories of TB risk, with a corresponding series of administrative, environmental, and respiratory protection control measures. The TB infection control measures recommended by CDC in 1994 were implemented widely in health-care facilities in the United States. The result has been a decrease in the number of TB outbreaks in health-care settings reported to CDC and a reduction in health-care-associated transmission of Mycobacterium tuberculosis to patients and health-care workers (HCWs). Concurrent with this success, mobilization of the nation's TB control programs succeeded in reversing the upsurge in reported cases of TB disease, and case rates have declined in the subsequent 10 years. Findings indicate that although the 2004 TB rate was the lowest recorded in the United States since national reporting began in 1953, the declines in rates for 2003 (2.3%) and 2004 (3.2%) were the smallest since 1993. In addition, TB infection rates greater than the U.S. average continue to be reported in certain racial/ethnic populations. The threat of MDR TB is decreasing, and the transmission of M. tuberculosis in health-care settings continues to decrease because of implementation of infection-control measures and reductions in community rates of TB. Given the changes in epidemiology and a request by the Advisory Council for the Elimination of Tuberculosis (ACET) for review and update of the 1994 TB infection control document, CDC has reassessed the TB infection control guidelines for health-care settings. This report updates TB control recommendations reflecting shifts in the epidemiology of TB, advances in scientific understanding, and changes in health-care practice that have occurred in the United States during the preceding decade. In the context of diminished risk for health-care-associated transmission of M. tuberculosis, this document places emphasis on actions to maintain momentum and expertise needed to avert another TB resurgence and to eliminate the lingering threat to HCWs, which is mainly from patients or others with unsuspected and undiagnosed infectious TB disease. CDC prepared the current guidelines in consultation with experts in TB, infection control, environmental control, respiratory protection, and occupational health. The new guidelines have been expanded to address a broader concept; health-care--associated settings go beyond the previously defined facilities. The term "health-care setting" includes many types, such as inpatient settings, outpatient settings, TB clinics, settings in correctional facilities in which health care is delivered, settings in which home-based health-care and emergency medical services are provided, and laboratories handling clinical specimens that might contain M. tuberculosis. The term "setting" has been chosen over the term "facility," used in the previous guidelines, to broaden the potential places for which these guidelines apply.

Cross Infection↗

Test for the integrity of environmental tractor cab filtration systems.

Cab filtration systems can be used to protect vehicle operators from hazardous air contaminants. In a cab filtration system, a fan draws air through filters and pressurizes the cab with this filtered air. This article describes the application of a low-cost, optical particle counter to evaluate the performance of tractor cab filtration systems. The tractors were equipped with environmental enclosures to protect the operators from pesticide exposures that occur during air blast spraying in orchards. Prior to testing, all environmental tractor cabs underwent a complete maintenance overhaul followed by a careful inspection by the manufacturer's field representative. As part of this maintenance effort, 13 tractors with cab filtration systems were tested in an enclosure. A Met One model 227B two-channel optical particle counter was used to measure the aerosol concentration outside and inside the cab. Ambient aerosol and/or aerosol generated by burning incense sticks were used to challenge the stationary cab filtration system in an enclosure. The ratio of the outside to inside concentration (Co/Ci) is the exposure reduction attained by the cab system. Alternatively, the inside concentration divided by the outside concentration times 100 (Ci/Co x 100) gives the percent penetration. All 13 tractors were tested for leak sites. Leak sites were identified and sealed. This process was repeated until each cab showed an exposure reduction ratio Co/Ci of at least 50 (aerosol penetration into the cab Ci/Co x 100 was less than 2%) at the 0.3-0.5 microm particle size interval.

Aerosols↗

Fitting characteristics of eighteen N95 filtering-facepiece respirators.

Four performance measures were used to evaluate the fitting characteristics of 18 models of N95 filtering-facepiece respirators: (1) the 5th percentile simulated workplace protection factor (SWPF) value, (2) the shift average SWPF value, (3) the h-value, and (4) the assignment error. The effect of fit-testing on the level of protection provided by the respirators was also evaluated. The respirators were tested on a panel of 25 subjects with various face sizes. Simulated workplace protection factor values, determined from six total penetration (face-seal leakage plus filter penetration) tests with re-donning between each test, were used to indicate respirator performance. Five fit-tests were used: Bitrex, saccharin, generated aerosol corrected for filter penetration, PortaCount Plus corrected for filter penetration, and the PortaCount Plus with the N95-Companion accessory. Without fit-testing, the 5th percentile SWPF for all models combined was 2.9 with individual model values ranging from 1.3 to 48.0. Passing a fit-test generally resulted in an increase in protection. In addition, the h-value of each respirator was computed. The h-value has been determined to be the population fraction of individuals who will obtain an adequate level of protection (i.e., SWPF >/=10, which is the expected level of protection for half-facepiece respirators) when a respirator is selected and donned (including a user seal check) in accordance with the manufacturer's instructions without fit-testing. The h-value for all models combined was 0.74 (i.e., 74% of all donnings resulted in an adequate level of protection), with individual model h-values ranging from 0.31 to 0.99. Only three models had h-values above 0.95. Higher SWPF values were achieved by excluding SWPF values determined for test subject/respirator combinations that failed a fit-test. The improvement was greatest for respirator models with lower h-values. Using the concepts of shift average and assignment error to measure respirator performance yielded similar results. The highest level of protection was provided by passing a fit-test with a respirator having good fitting characteristics.

Adult↗

Comparison of five methods for fit-testing N95 filtering-facepiece respirators.

Five fit-testing methods (Bitrex, ambient aerosol condensation nuclei counter using the TSI PortaCount Plus, saccharin, modified ambient aerosol condensation nuclei counter using the TSI PortaCount Plus with the N95-Companion, and generated aerosol using corn oil) were evaluated for their ability to identify poorly fitting N95 filtering-facepiece respirators. Eighteen models of NIOSH-certified, N95 filtering-facepiece respirators were tested by a panel of 25 subjects using each fit-testing method. The penetration of the corn oil and the ambient aerosols through the filter media of each respirator was measured in order to adjust the corresponding generated and ambient aerosol overall fit factors, reflecting only face-seal leakage. Fit-testing results were compared to 5th percentiles of simulated workplace protection factors. Beta errors (the chance of passing a fit-test in error) ranged from 3 percent to 11 percent. Alpha errors (the chance of failing a fit-test in error) ranged from 51 percent to 84 percent. The ambient aerosol using the TSI PortaCount Plus and the generated aerosol methods identified poorly fitting respirators better than the saccharin, the Companion, and Bitrex methods. These errors rates should be considered when selecting a fit-testing method for fitting N95 filtering-facepieces. When both types of errors were combined as an assignment error, the ambient aerosol method using the TSI PortaCount Plus had the lowest percentage of wearers being assigned a poor-fitting respirator.

Aerosols↗

Improving the health of workers in indoor environments: priority research needs for a national occupational research agenda.

Indoor nonindustrial work environments were designated a priority research area through the nationwide stakeholder process that created the National Occupational Research Agenda. A multidisciplinary research team used member consensus and quantitative estimates, with extensive external review, to develop a specific research agenda. The team outlined the following priority research topics: building-influenced communicable respiratory infections, building-related asthma/allergic diseases, and nonspecific building-related symptoms; indoor environmental science; and methods for increasing implementation of healthful building practices. Available data suggest that improving building environments may result in health benefits for more than 15 million of the 89 million US indoor workers, with estimated economic benefits of $5 to $75 billion annually. Research on these topics, requiring new collaborations and resources, offers enormous potential health and economic returns.

Air Pollutants, Occupational↗

Method for Evaluating Germicidal Ultraviolet Inactivation of Biocontaminated Surfaces.

Safety issues related to work-site conditions often deal with potential worker exposure to infectious airborne microorganisms due to their dissemination in indoor air and contamination of surfaces. Germicidal ultraviolet (GUV) radiation is used in health-care settings and other occupational environments for microbial inactivation. In this study, a new methodology for determining the efficiency of GUV microbial inactivation of surfaces was developed and evaluated. The method utilizes identical chambers in which test microorganisms are irradiated on agar surfaces at different humidity and irradiation intensity levels. The effects of GUV intensity and exposure time on microbial inactivation were examined for Micrococcus luteus and Serratia marcescens. It was found that at low humidity levels (20-25%) both organisms can be inactivated with at least 95% efficiency if the GUV intensity exceeds 50 μW/cm2 for at least 3-5 min (corresponding to a dose of ~ 10 mJ/cm2). The radiation dose needed for effective inactivation of S. marcescens, as measured by a UV meter near the microbial sample, was found not to be affected by the humidity level, whereas that of M. luteus increased at higher humidities. The findings of this study can be used to determine sufficient GUV inactivation doses for occupational environments with various microbial contaminations.

UV inactivation↗

Environmental agricultural tractor cab filter efficiency and field evaluation.

To evaluate filter efficiency and performance of environmental enclosures for tractors, 3- to 4-year-old tractor enclosure combinations (cabs retrofitted to tractors after manufacturing) were studied at a custom pesticide applicators facility. Optical particle counters were used to measure the aerosol number concentration inside and outside the cab. The ratio of these concentrations multiplied by 100 is termed percentage penetration, the amount of the aerosol that penetrates into the enclosure. For particles in the 0.3 to 0.4 microm range, penetration into the cab was reduced from 11 to 0.4% in the following sequential steps. First, manufacturing mistakes were corrected by fixing a bowed flange and inappropriate sealing of the sheet metal used to separate incoming air from air that had passed through the filter. This reduced aerosol penetration from 11 to 4.8%. Replacing gasket material on the used filter reduced penetration from 4.8 to 0.65%. This suggests that the filter gaskets are deforming and allowing leakage. Also, the filter media were evaluated for aerosol penetration as a function of particle size and were tested per the criteria stipulated in 42 CFR 84 for negative pressure air-purifying particulate respirators. These results showed penetration through the filter media of less than 0.03%, indicating that filter media were not a major source of aerosol leakage into the cab. The results suggest that the manufacturer should implement a quality control program to ensure that minimal aerosol penetration criteria into the cabs are met and an acceptable maintenance program exists to ensure compliance. Furthermore, the degradation of filter gasket material over time needs to be minimized to ensure that the environmental cabs continue to provide acceptable performance.

Agriculture↗

Correlation between quantitative fit factors and workplace protection factors measured in actual workplace environments at a steel foundry.

Past studies have found little or no correlation between workplace protection factors (WPFs) and quantitative fit factors (FFs). This study investigated the effect of good- and poor-fitting half-facepiece, air-purifying respirators on protection in actual workplace environments at a steel foundry and the correlation between WPFs and FFs. Fifteen burners and welders, who wore respirators voluntarily, and chippers participated in this study. Each subject was fit-tested with two respirator models each with three sizes, for a total of six fit-tests. Models and sizes were assigned this way to provide a wide range of FFs among study participants. Each worker donned the respirator twice per day (at the beginning of the shift and following the lunch break) for 2 days. Quantitative FFs were first obtained for each donning using the PortaCount Plus trade mark in a separate room. Without redonning the respirators, workers performed normal work for 1 to 2 hours, and WPFs were measured by collecting ambient and in-facepiece samples simultaneously. A second fit-test was conducted without disturbing the respirator. FFs were obtained by averaging the results from the first and second fit-tests. The resulting FFs had a geometric mean (GM) of 400 (range=10-6010) and a geometric standard deviation (GSD) of 6.1. Of the 55 valid donnings, 43 were good fitting (FFs> or =100) and 12 were poor fitting (FFs<100). The WPFs had a GM of 920 (range=13-230,000) and a GSD of 17.8. The WPFs were found to be significantly correlated with the FFs (R(2)=.55 and p-value=.0001). Therefore, FF was shown to be a meaningful indicator of respirator performance in actual workplace environments.

Adult↗