PubMed Health⌕ Search

Biomedical subjects

Paul C H Li

Publications and source records attributed to Paul C H Li.

10 recordsLinked to original sources

Contraction study of a single cardiac muscle cell in a microfluidic chip.

This chapter introduces a microfluidic method to study the contraction of a single cardiac muscle cell (cardiomyocyte). This method integrates single-cell selection, cell retention, dye loading, chemical stimulation, and fluorescence measurement for intracellular calcium on one microfluidic chip. Before single-cell experiments, the bonded chip was modified in order to make the channel deep enough to accommodate a large, single cardiomyocyte. After the modification, a single heart muscle cell could be selected and retained at a cell retention structure. Fluo-4 AM was loaded in the cell for the measurement of intracellular calcium ion concentration in the cell. Subsequently, caffeine was introduced into the chamber to induce the contraction of the cardiomyocyte. During contraction, fluorescence measurement was used to monitor the intracellular calcium level,and an optical imaging system was used to monitor the shape to confirm the contraction. The resting [Ca2+]i of cardiomyocyte was determined and was consistent with the value of approx 100 nM in the literature.

Aniline Compounds↗

Extraction of pure cellular fluorescence by cell scanning in a single-cell microchip.

A 3-dimensional liquid flow control method has been developed to manipulate and retain a single yeast cell freely in a microchip. This method allows us to carry out single-cell experiments by selecting any desired single cell from a group, retaining the cell for cellular signal detection, and delivering reagents to the cell during continual detection and observation without any negative impact from the liquid flow on the live cell. The cell was scanned back and forth across an observation window in order to extract pure cellular fluorescent signals. Different scanning methods were discussed for effective collection of the cellular fluorescent signal. The cell scanning technique results in many advantages, such as distinguishing a small part of a cell, allowing for background correction and monitoring the switch of reagents. In addition, it is possible to evaluate the photobleaching effects on both the background and cellular fluorescence, with the latter found to be less significant in a restricted cellular environment.

Fluorescence↗

Microfluidic selection and retention of a single cardiac myocyte, on-chip dye loading, cell contraction by chemical stimulation, and quantitative fluorescent analysis of intracellular calcium.

A microfluidic method to study the contraction of a single cardiac myocyte (heart muscle cell) has been developed. This method integrates various single-cell operations as well as on-chip dye loading, and quantitative analysis of intracellular calcium concentration, [Ca2+]i. After the channel enlargement by on-chip etching to accommodate large-sized cardiac myocytes, a single cell is selected and retained at a V-shaped cell retention structure within the microchip. Owing to the fragile property of the cardiac myocytes that could easily be damaged by centrifugation, the calcium-sensitive fluorescent dye was loaded in the cell by on-chip dye loading. This on-chip method minimized the damage to the cells from the use of a centrifuge in the conventional method and provided a way of cellular analysis of fragile cells. Subsequently, quantitative analysis of [Ca2+]i of a single cardiac myocyte by fluorescence measurement was achieved for the first time in a microfluidic chip, thanks to the intracellular calcium stimulant of ionomycin. The resting [Ca2+]i of the cardiomyocyte determined was consistent with the literature value. From the spontaneous contraction study, it was found that fluorescence intensity cannot represent the [Ca2+]i variation accurately, which implied the importance of the quantitative analysis of [Ca2+]i.

Animals↗

A three-dimensional flow control concept for single-cell experiments on a microchip. 2. Fluorescein diacetate metabolism and calcium mobilization in a single yeast cell as stimulated by glucose and pH changes.

Using a three-dimensional flow control concept to manipulate and retain a single yeast cell in a microchip, we were able to study the kinetics of intracellular metabolism and calcium mobilization at the single-cell level, as stimulated by glucose and pH changes. As a model study, the fluorogenic substrate fluorescein diacetate (FDA) was chosen to study how the intracellular carboxylesterase metabolize it. A single yeast cell was first cultured in the microchip. Thereafter, under a constant concentration of FDA, influx of FDA into the yeast cell occurred and FDA was hydrolyzed or metabolized. It was found that changes in both pH and glucose stimulated the FDA metabolism in a yeast cell, and the stimuli can elicit multiple responses from the cell. Since it was carried out within the microchip, the whole experiment on one single yeast cell could last for as long as 10 h. The dormant cell, budding cell, and pretreated budding cell (in low-pH buffer) of yeast resulted in different responses. Experimental data provided details on the FDA metabolism at the single-cell level and revealed strong correlations between FDA metabolism and calcium mobilization. Furthermore, efflux of the FDA metabolite fluorescein could start spontaneously if there was glucose in the medium. The experiments on a single cell were of the "human cell conservation" style because the cell responded to the reagent changes implemented by the human researcher. A mathematical model was also developed to study the influx-hydrolysis-efflux processes of the FDA metabolism using single-cell fluorescent data. These long overdue single-cell experiments are now rendered possible using the three-dimensional flow control in the microchip.

Calcium↗

A three-dimensional flow control concept for single-cell experiments on a microchip. 1. Cell selection, cell retention, cell culture, cell balancing, and cell scanning.

An ideal microchip for single-cell experiments should be able to allow us to culture cells, to select any desired single cell from a group, to retain the cell for convenient cellular signal detection, and to deliver any buffer or reagent directly to the cell at any time during continual detection and observation. Most importantly, any negative impact on the live cell should be minimized. To accomplish all these functions, we developed a three-dimensional liquid flow control concept and employed special liquid flow fields to manipulate and retain a single yeast cell freely in the chip. A zero-speed point was controlled to retain the cell for three-dimensional cell balancing and cell scanning. A dispersive flow delivered reagents at a high speed to very near the cell and provided them to the cell at a low speed. No force stronger than its gravitational force was exerted on the cell, which could be balanced on different positions on an arc-sloping wall, thus minimizing any negative impact on the cell due to strong liquid flows. Specifically, we demonstrate on-chip single-cell culture, cell wall removal, and reagent delivery. Subsequently, single-cell fluorescence detection was performed, and noise filtering and background correction were applied for data processing.

Cell Culture Techniques↗

Gas chromatography-mass spectrometry determination of matrine in human plasma.

A method was developed for the quantification of matrine in human plasma using a liquid-liquid extraction procedure followed by gas-chromatography-mass spectrometry (GC/MS) analysis. Deuterated matrine, an internal standard of the analysis, was spiked into the plasma samples before extraction. Linear detection responses were obtained for matrine concentrations ranging from 10 to 500 ng/ml. The intra-day and inter-day precision ranged from 0.4 to 4.0% and 1.0-3.5%, respectively. The intra-day accuracy was between -7.3 and 4.5%. The limit of quantification for matrine was 23 ng/ml. The extraction efficiency averaged about 38%. The validated GC/MS method will be used to quantify matrine in human plasma samples collected in a clinical trial study.

Alkaloids↗

Transport, retention and fluorescent measurement of single biological cells studied in microfluidic chips.

Cellular manipulation and fluorescent measurement were performed on two types of biological cells. First, transport and retention of yeast cells were demonstrated on a glass microfluidic chip, which consists of special U-shaped microstructures. These microstructures have the openings parallel to the liquid flow and weirs perpendicular to the flow. These allow the retention of yeast cells in the U-shaped pocket and drainage of liquid over the weirs. Thereafter, the same chip was used to carry out real-time fluorescent measurement for the cellular changes in single Jurkat T cells. In this case, the Jurkat cells were localized inside the straight portion of a microchannel. Fluorescent imaging on the same, single suspension cell was carried out to study two cellular processes occurring in viable cells, (1) the intracellular conversion of fluorescein diacetate (FDA) to fluorescein; (2) the degradation of an inhibitory protein, IkappaB, as involved in the NF-kappaB signalling pathway. In the former, the increase in fluorescent intensity of single Jurkat T cells (due to fluorescein formation) was measured; whereas in the latter, the decrease in the fluorescent intensity of a single transfected Jurkat cell (due to the degradation of the IkappaB-EGFP fusion protein) was monitored. In addition, we employed a Jurkat cell expressed with IkappaB-EGFP to probe any possible action of an herbal compound, isoliquiritigenin (IQ), on the degradation of IkappaB-EGFP. These examples have demonstrated that Jurkat cells remain viable within microfluidic channels for cellular studies and that the microfluidic chip can facilitate monitoring of cellular changes of biological cells at the single cell level and in the same cell.

Biological Transport↗

Chemical analysis of raw, dry-roasted, and honey-roasted licorice by capillary electrophoresis.

In herbal medicine, licorice is usually processed using a roasting procedure which might modify the chemical compositions in licorice. To test this hypothesis, licorice root samples were roasted under various conditions (with or without honey) and subsequently extracted by refluxing with 95% ethanol. The analysis of chemical compositions of licorice root extracts was achieved by capillary electrophoresis. The running buffer has been optimized to be 50 mM sodium tetraborate (pH 9.01) containing 5 mM beta-cyclodextrin. Thermal decomposition of glycyrrhizin, which was a major ingredient in licorice, was first studied in detail, indicating the conversion of glycyrrhizin to glycyrrhetinic acid. The licorice extracts were then analyzed to indicate the above thermal conversion did occur in the licorice samples. This finding may shed some light on understanding the differences in the therapeutic values of raw versus roasted licorice in herbal medicine.

Chalcone↗

An acoustic wave sensor incorporated with a microfluidic chip for analyzing muscle cell contraction.

We report the fabrication of a microfluidic chip or lab-on-a-chip integrated with a thickness-shear mode (TSM) acoustic wave sensor for muscle cell analysis. The sensor, essentially an AT-cut quartz crystal, serves as a detector for recording changes in acoustic wave properties occurring in an attached cardiomyocyte (single heart muscle cell) during its contraction and relaxation. Presumably, the changes resulted from alterations in viscoelastic properties (e.g. stiffness) of the cells. The effects of excitation electrode size, the presence of a microfluidic channel plate, and liquid loading on the sensor were first examined. Thereafter, muscle cell contraction analysis upon chemical stimuli were described. The potential of the chip for screening of cardiovascular drugs is discussed.

Animals↗

Acoustic wave detection of chemical species electrokinetically transported within a capillary tube.

For the first time, we report the acoustic wave detection of chemical species being transported in a capillary tube to a region where acoustic coupling occurs. The measured parameter was a change in phase, which was originally only attributed to a change in solution density as the analyte passed by the detection region. Accordingly, we report the detection of change in phase as various chemical species (e.g. Cy5 dye, Cy5-derivatized glycine and underivatized glycine) were introduced into and migrated along a capillary tube through electrokinetic processes. To improve detection sensitivity, we modified various experimental parameters, such as run buffer concentration, capillary wall thickness and transducer frequency. Although acoustic wave detection was feasible, the peak width and detection limit were inadequate as compared to conventional detection methods for HPLC or CE. Nevertheless, the effects of various physical and chemical relaxation processes on acoustic wave absorption were discussed, and this has shed some light on explaining some observations, which cannot be explained by density differences alone. Accordingly, the acoustic wave method is suggested to investigate these processes, as studied in ultrasonic relaxation spectroscopy, in a flow system.

Journal Article↗