PubMed Health⌕ Search

Biomedical subjects

Paul E Beaulé

Publications and source records attributed to Paul E Beaulé.

At least 19 recordsLinked to original sources

Femoral head blood flow during hip resurfacing.

Preserving femoral head vascularity during hip resurfacing may avoid femoral neck fractures and late femoral loosening. The posterior approach and notching of the femoral neck influence femoral head perfusion. However, it is not known if standard preparation of the femoral head during hip resurfacing can disrupt blood flow. Ten patients (10 hips) with advanced osteoarthritis having metal-on-metal hip resurfacing by means of a vascular-preserving surgical approach had femoral head blood flow measurements using laser Doppler flowmetry. Nine hips had a mean decrease of 70% in femoral head blood flow after standard reaming and preparation. The data suggest femoral head reaming during hip resurfacing substantially impacts blood flow to the femoral head and infers the extra osseous blood supply is still important in the arthritic femoral head. To avoid damaging the retinacular vessels, surgeons should direct the cylindrical reamer superolaterally staying as close as possible to the inferomedial neck.

Adolescent↗

The value of patient activity level in the outcome of total hip arthroplasty.

Commonly used total hip arthroplasty scores take into account pain, function, walking, and range of motion. The purpose of this study was to evaluate the value of patient activity level as part of the outcome of total hip arthroplasty. Using linear regression analysis, the relationship between patient activity level (University of California Los Angeles activity score), the Harris Hip Score, and the Short Form-12 health survey was evaluated in 152 patients (mean age, 58.7 years) with a mean follow-up 5.2 years (range, 2-21 years). The University of California Los Angeles activity scale had an R(2) value of 0.39 and 0.19 to the Short Form-12 physical and mental components, respectively, and 0.32 to the Harris Hip Score. By evaluating patient activity level, one obtains important qualitative information in assessing the clinical outcome after total hip arthroplasty.

Arthroplasty, Replacement, Hip↗

Metal-on-metal hybrid surface arthroplasty. Surgical Technique.

BACKGROUND: Following the reintroduction of metal-on-metal articulating surfaces for total hip arthroplasty in Europe in 1988, we developed a surface arthroplasty prosthetic system using a metal-on-metal articulation. The present study describes the clinical and radiographic results of the first 400 hips treated with metal-on-metal hybrid surface arthroplasties at an average follow-up of three and a half years. METHODS: Between November 1996 and November 2000, 400 metal-on-metal hybrid surface arthroplasties were performed in 355 patients. All femoral head components were cemented, but only fifty-nine of the short metaphyseal stems were cemented. The patients had an average age of forty-eight years, 73% were men, and 66% had a diagnosis of osteoarthritis. Clinical and radiographic follow-up was performed at three months postoperatively and yearly thereafter. RESULTS: The majority of the patients returned to a high level of activity, including sports, and 54% had activity scores of >7 on the University of California at Los Angeles activity assessment system. Kaplan-Meier survivorship curves demonstrated that the rate of survival of the components at four years was 94.4%. For patients with a surface arthroplasty risk index score of >3, the rate of survival of the components at four years was 89% compared with a rate of 97% for those with a score of <or=3. The patients with a higher risk index were 4.2 times more likely to undergo revision to a total hip replacement at four years. Twelve hips (3%) had a revision to a total hip replacement. Seven of the twelve hips were revised because of loosening of the femoral component, and three were revised because of a femoral neck fracture. Substantial radiolucencies were seen around sixteen uncemented metaphyseal femoral stems. No femoral radiolucencies were observed among the hips in which the metaphyseal stem was cemented. The most important risk factors for femoral component loosening and substantial stem radiolucencies were large femoral head cysts (p = 0.029), patient height (p = 0.032), female gender (p = 0.005), and smaller component size in male patients (p = 0.005). CONCLUSIONS: The preliminary experience with this hybrid metal-on-metal bearing is encouraging. Optimal femoral bone preparation and component fixation are critical to improving durability. The metal-on-metal hybrid surface arthroplasty is easily revised to a standard femoral component if necessary.

Adolescent↗

Trans-sacral fixation for failed posterior fixation of the pelvic ring.

INTRODUCTION: In the treatment of certain pelvic ring pathologies (non-unions and failure of ilio-sacral screw fixation) trans-sacral fixation (i.e. fixation from iliac wing to the other traversing the body of S1) may be necessary. The purpose of our study was to describe our early experience and describe the surgical technique. MATERIALS AND METHODS: Seven cases of trans-sacral fixation were identified with a mean patient age of 49-years-old with four females and three males. The diagnosis at the time of trans-sacral fixation was failure of posterior ring fixation in four (three of which had vertical sacral fractures), mal-position of iliosacral (IS) screw in one, failure of fusion of sacroiliac (SI) joint in two. All these cases were augmented with a 4.5 mm reconstruction plate placed in tension posteriorly. RESULTS: At average follow up of 39 months (range 24-75), all patients achieved union. There were no neurological or vascular complications. Two patients required reoperations prior to union. Our current use for this technique is with a 8.0 mm screw (16 mm thread). CONCLUSIONS: Initial experience with trans-sacral fixation has proven to be very effective technique to solve the most difficult problems in posterior pelvic ring fixation. We reserve its use to the following indications: nonunion/malunion of the pelvic ring, and sacral fractures.

Aged↗

Patient selection and surgical technique for surface arthroplasty of the hip.

Factors such as patient selection, surgical technique, and durable fixation of the components are critical in surface arthroplasty of the hip. The Surface Arthroplasty Risk Index helps determine the risk of failure, with an index score </=3 having a 97% survivorship at 4 years. Because surface arthroplasty of the hip is conservative in nature and has the goal to closely reproduce the normal anatomy of the proximal femur, surgeons performing this procedure need to take into consideration the underlying pathology that led to the degenerative changes. Consequently, choice of surgical approach and positioning of the implants may have a greater impact on implant survivorship and patient function than in standard hip replacement. This article presents case illustrations of different hip pathologies treated by surface arthroplasty of the hip.

Adolescent↗

Clinical correlation of femoral component migration in hip resurfacing arthroplasty analyzed by Einzel-Bild-Röntgen-analyze-femoral component analysis.

Hip resurfacing arthroplasty using metal-on-metal bearings has become increasingly popular. Wear of these bearings has been imperceptible on plain radiographs. Migration analysis studies may represent the opportunity to detect early failures and evaluate long-term prosthetic survival. The authors retrospectively reviewed 29 hips in a consecutive series of metal-on-metal hip resurfacing arthroplasties with a long-term clinical follow-up (average 8.7 years) to analyze the femoral component migration pattern by means of Einzel-Bild-Röntgen-Analyze-femoral component analysis (EBRA-FCA). Femoral component migrations at 2 years and latest follow-up were compared with the known clinical outcomes. The authors' findings add validity to EBRA-FCA as a means to monitor femoral component migration and the clinical outcome of metal-on-metal hip resurfacing arthroplasty.

Arthroplasty, Replacement, Hip↗

Three-dimensional computed tomography of the hip in the assessment of femoroacetabular impingement.

Femoroacetabular impingement secondary to the cam effect is thought to be associated with an insufficient anterior concavity in the sagittal/axial plane of the femoral head-neck junction. Using three-dimensional computed tomography the anterior and posterior concavity of the femoral head-neck junction was assessed in 36 painful non-dysplastic hips (30 patients). The mean age of the symptomatic hips was 40.7 with 13 females and 17 males. Eighteen out of the 36 hips had a pistol grip deformity. Magnetic resonance gadolinium arthrography was performed to assess for labral and cartilage lesions. Alpha and beta angles measuring the anterior and posterior femoral head-neck junction concavities were also determined in 20 asymptomatic hips (12 patients; mean age 37, 5 females and 7 males) using three-dimensional computed tomography. The mean alpha angle for the symptomatic and the control group were: 66.4 versus 43.8 (p=0.001), and for the beta angle 40.2 versus 43.8 (p=0.011), respectively. All but one of the symptomatic hips had a labral tear with 61% of these hips having associated cartilage damage. Three-dimensional computed tomography represents an accurate tool to quantify the femoral head-neck concavity providing a non-invasive assessment of hips at risk of femoroacetabular impingement.

Acetabulum↗

Meperidine-induced seizure after revision hip arthroplasty.

Musculoskeletal injuries secondary to seizures are well documented and have a variable incidence. Meperidine (Demerol [Abbott, Abbott Park, IL]) has been used for many years in the postoperative setting for pain control; however, in high doses, it has been associated with seizure. We report the case of patient who experienced a tonic-clonic seizure 5 days after hip revision surgery, resulting in dissociation of the socket from the acetabulum with an associated acetabular fracture. In this patient, meperidine administered for patient-controlled analgesia within recommended range caused the seizure.

Acetabulum↗

Metal-on-metal surface arthroplasty with a cemented femoral component: a 7-10 year follow-up study.

Forty-two McMinn metal-on-metal surface arthroplasties were implanted in 23 males and 16 females, average age 47.5 years old. The overall survivorship at 7 years was 79%; with any reoperation surgery as endpoint, 80%; and 93%; with aseptic loosening of the socket and femoral component, respectively. The average Surface Arthroplasty Risk Index of patients who had failed or were at risk of failing on the femoral side was significantly greater than for the rest of the cohort, 3.9 versus 1.9. The overall survivorship of the McMinn component was unacceptably low, with the majority of failures occurring with the cemented acetabular components. The recent reintroduction of surface arthroplasty of the hip using metal-on-metal bearings and cementless acetabular components may benefit young patients with hip arthritis with appropriate patient selection.

Adult↗

Surface arthroplasty for osteonecrosis of the hip: hemiresurfacing versus metal-on-metal hybrid resurfacing.

Eighty-four hips with Ficat stage III and IV osteonecrosis were treated: 56 with metal-on-metal surface arthroplasty (MMSA) and 28 with hemi-surface arthroplasty (HSA). Average follow-up was 4.9 years. UCLA hip scores were significantly better for MMSA versus HSA for function and activity as well as Harris Hip scores and physical component of the SF-12 scores. In the MMSA group, 2 hips were revised to total hip arthroplasty for femoral loosening, and 5 hips had adverse radiological changes. In the HSA group, 4 hips were revised (1 sepsis and 3 for pain). There was no evidence of any femoral loosening or neck narrowing in the HSA group. Although the functional clinical outcome of MMSA is superior to HSA, long-term follow up of MMSA will determine the reliability of the femoral fixation.

Adolescent↗

Fixation strength of an all-metal acetabular component cemented into an acetabular shell: a biomechanical analysis.

When an acetabular shell is well fixed but the locking mechanism is compromised, cementing a new liner into the existing acetabular component can provide a simple revision solution. The pull-out and torsional fixation strength of cobalt chromium (CoCr) alloy acetabular components cemented into 3 sizes of titanium alloy acetabular components was tested under conditions of 0 or 2 mm cement mantle at the dome and 2 mm cement with the cemented component in 20 degrees of version with respect to the shell. The lowest mean tensile load to failure was 1500 N, and occurred with no cement at the dome of the 54 mm shell, whereas the greatest load was with 2 mm cement thickness. Smallest mean torque to failure was 43 Nm. Version angle did not substantially change failure load. Although not cyclically loaded, fixation strength of metal liners cemented into shells was comparable to that of commonly used locking mechanisms, suggesting sufficient strength for clinical application.

Acetabulum↗

Hip arthrodesis: a procedure for the new millennium?

Advanced hip arthrosis in the young patient represents a difficult problem. Using currently available techniques, total hip arthroplasty (THA) in this patient population likely would result in multiple revision surgeries, usually at the expense of bone in the proximal femur and acetabulum. For noninflammatory, monoarticular hip arthritis, arthrodesis remains an excellent reconstruction option. Arthrodesis can provide pain relief and return to function in the majority of patients indicated for the procedure. Current techniques provide acceptable fusion rates. If possible, techniques that protect the abductor mechanism and limit deformity of the pelvis should be used. Patient education is an important part of the treatment process. The position of the limb is important to early satisfaction and durability of the fusion. Long-term difficulties after hip fusion are related to pain in contiguous joints. Conversion arthroplasty, if necessary, can result in favorable outcomes. Familiarity with the techniques and outcomes of hip arthrodesis are important for the hip surgeon to understand.

Adolescent↗

The Levine anterior approach for total hip replacement as the treatment for an acute acetabular fracture.

The treatment of acetabular fractures in part relies on the selection of a specific surgical approach that allows for accurate reduction of fracture fragments. Moreover, these acetabular approaches were not developed for the insertion of a total hip replacement. Therefore, if a total hip arthroplasty is to be the treatment of an acute acetabular fracture, a single incision that permits reduction of the acetabular fracture fragments and ease of insertion of the arthroplasty components would be desirable. The Levine anterior approach provides both accesses to the anterior wall/column for reduction and fixation and to the femoral shaft for insertion of a total hip replacement. This paper describes that surgical technique and our initial clinical experience with this approach for acute acetabular fractures. A consecutive group of 10 patients with acetabular fractures, all involving the anterior wall/column with articular impaction (>50% of the acetabular roof) including 2 cases with an associated posterior hemitrans-verse component, were reviewed. After fracture reduction and fixation, a hybrid total hip replacement was implanted in all cases with an average acetabular component size of 56 mm (range 52-64). At a mean follow-up of 36 months (range 24-53), all fractures united, and all acetabular components remained fixed with no evidence of migration or loosening. There were 2 complications, a Brooker grade II heterotopic ossification and 1 postoperative anterior dislocation treated successfully with closed reduction and spica cast immobilization. The average Merle d'Aubigné hip score at latest follow-up was 16 (range 13-18). The Levine anterior approach is a reliable, safe, and efficient technique that permits early mobilization of patients with anterior wall/column acetabular fractures requiring a total hip replacement.

Acetabulum↗

Prevention and treatment of dislocation after total hip replacement using large diameter balls.

The purpose of this study was to review safety and efficacy of total hip arthroplasty using large-diameter femoral heads in treatment and prevention of dislocation. One hundred forty hips in 135 patients were replaced using femoral heads at least 36 mm in diameter. The average age of the patients was 61.6 years. The patients were grouped into three categories depending on their diagnoses: recurrent dislocations from previous total hip replacements (Group 1; 29 hips); revision surgeries not including revisions for dislocations (Group 2; 54 hips); and primary surgeries (Group 3; 57 hips). The average followup was 5.5 years (range, 1-17 years). A total of 16 hips were revised: six for instability, four for fracture or disassociation of a conventional polyethylene liner, three for aseptic loosening of the socket, and three for sepsis. One hip from Group 1 dislocated at 12.5 years postoperatively, was treated with closed reduction, and since has been nonrecurring. UCLA hip scores all improved significantly. The prevalence of dislocation varied among the three groups, with 13.7% for Group 1, 1.8% for Group 2, and 3.5% for Group 3. The failure in the six cases that required revision for instability was attributable to poor socket orientation. All the hips became stable after revision without the use of a constrained acetabular liner. Large-diameter femoral heads provide additional stability not only for patients with recurrent dislocations, but also for patients having revision. The new, more wear-resistant bearings now enable the surgeon to extend the use of big femoral heads to primary total hip arthroplasty. Metal-on-metal seems to be the material of choice for a bone-conserving reconstruction with large femoral heads.

Adolescent↗