Paul E Kinahan

Publications and source records attributed to Paul E Kinahan.

18 recordsLinked to original sources

[11C]metahydroxyephedrine and [18F]fluorodeoxyglucose positron emission tomography improve clinical decision making in suspected pheochromocytoma.

BACKGROUND: Pheochromocytomas are rare tumors of chromaffin cells for which the optimal management is surgical resection. Precise diagnosis and localization may be elusive. We evaluated whether positron emission tomography (PET) scanning with the combination of [18F]fluorodeoxyglucose (FDG) and the norepinephrine analogue [11C]metahydroxyephedrine (mHED) would allow more exact diagnosis and localization. METHODS: Fourteen patients with suspected pheochromocytoma were evaluated by anatomical imaging (computed tomography or magnetic resonance imaging) and [131I]metaiodobenzylguanidine (MIBG) planar imaging. PET imaging was performed by using mHED with dynamic adrenal imaging, followed by a torso survey and FDG with a torso survey. Images were evaluated qualitatively by an experienced observer. RESULTS: Eight patients had pathology-confirmed pheochromocytoma. Of the other six, two patients had normal adrenal tissue at adrenalectomy, and the other four had subsequent clinical courses inconsistent with a diagnosis of pheochromocytoma. In four of eight patients with pheochromocytoma, MIBG failed to detect one or more sites of pathology-confirmed disease. The mHED-PET detected all sites of confirmed disease, whereas FDG-PET detected all sites of adrenal and abdominal disease, but not bone metastases, in one patient. MIBG and FDG-PET results were all negative in the six patients without pheochromocytoma. One patient with adrenal medullary hyperplasia had a positive mHED-PET scan. PET scanning aided the decision not to operate in three of six patients. The resolution of PET functional imaging was superior to that of MIBG. CONCLUSIONS: PET scanning for pheochromocytoma offers improved quality and resolution over current diagnostic approaches. PET may significantly influence the clinical management of patients with a suspicion of these tumors and warrants further investigation.

3-Iodobenzylguanidine↗

Modeling and incorporation of system response functions in 3-D whole body PET.

Appropriate application of spatially variant system models can correct for degraded resolution response and mispositioning errors. This paper explores the detector blurring component of the system model for a whole body positron emission tomography (PET) system and extends this factor into a more general system response function to account for other system effects including the influence of Fourier rebinning (FORE). We model the system response function as a three-dimensional (3-D) function that blurs in the radial and axial dimension and is spatially variant in radial location. This function is derived from Monte Carlo simulations and incorporates inter-crystal scatter, crystal penetration, and the blurring due to the FORE algorithm. The improved system model is applied in a modified ordered subsets expectation maximization (OSEM) algorithm to reconstruct images from rebinned, fully 3-D PET data. The proposed method effectively removes the spatial variance in the resolution response, as shown in simulations of point sources. Furthermore, simulation and measured studies show the proposed method improves quantitative accuracy with a reduction in tumor bias compared to conventional OSEM on the order of 10%-30% depending on tumor size and smoothing parameter.

Algorithms↗

Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors.

Accurate quantitation of positron emission tomography (PET) tracer uptake levels in tumors is important for staging and monitoring response to treatment. Quantitative accuracy in PET is particularly poor for small tumors because of system partial volume errors and smoothing operations. This work proposes a reconstruction algorithm to reduce the quantitative errors due to limited system resolution and due to necessary image noise reduction. We propose a method for finding and using the detection system response in the projection matrix of a statistical reconstruction algorithm. In addition, we use aligned anatomical information, available in PET/CT scanners, to govern the penalty term applied during each image update. These improvements are combined with Fourier rebinning in a clinically feasible algorithm for reconstructing fully three-dimensional PET data. Results from simulation and measured studies show improved quantitation of tumor values in terms of bias and variance across multiple tumor sizes and activity levels with the proposed method. At common clinical image noise levels for the detection task, the proposed method reduces the error in maximum tumor values by 11% compared to filtered back-projection and 5% compared to conventional iterative methods.

Algorithms↗

Tumor delineation using PET in head and neck cancers: threshold contouring and lesion volumes.

Tumor boundary delineation using positron emission tomography (PET) is a promising tool for radiation therapy applications. In this study we quantify the uncertainties in tumor boundary delineation as a function of the reconstruction method, smoothing, and lesion size in head and neck cancer patients using FDG-PET images and evaluate the dosimetric impact on radiotherapy plans. FDG-PET images were acquired for eight patients with a GE Advance PET scanner. In addition, a 20 cm diameter cylindrical phantom with six FDG-filled spheres with volumes of 1.2 to 26.5 cm3 was imaged. PET emission scans were reconstructed with the OSEM and FBP algorithms with different smoothing parameters. PET-based tumor regions were delineated using an automatic contouring function set at progressively higher threshold contour levels and the resulting volumes were calculated. CT-based tumor volumes were also contoured by a physician on coregistered PET/CT patient images. The intensity value of the threshold contour level that returns 100% of the actual volume, I(V100), was measured. We generated intensity-modulated radiotherapy (IMRT) plans for an example head and neck patient, treating 66 Gy to CT-based gross disease and 54 Gy to nodal regions at risk, followed by a boost to the FDG-PET-based tumor. The volumes of PET-based tumors are a sensitive function of threshold contour level for all patients and phantom datasets. A 5% change in threshold contour level can translate into a 200% increase in volume. Phantom data indicate that I(V100) can be set as a fraction, f, of the maximum measured uptake. Fractional threshold values in the cylindrical water phantom range from 0.23 to 0.51. Both the fractional threshold and the threshold-volume curve are dependent on lesion size, with lesions smaller than approximately 5 cm3 displaying a more pronounced sensitivity and larger fractional threshold values. The threshold-volume curves and fractional threshold values also depend on the reconstruction algorithm and smoothing filter with more smoothing requiring a higher fractional threshold contour level. The threshold contour level affects the tumor size, and therefore the ultimate boost dose that is achievable with IMRT. In an example head and neck IMRT plan, the D95 of the planning target volume decreased from 7770 to 7230 cGy for 42% vs. 55% contour threshold levels. PET-based tumor volumes are strongly affected by the choice of threshold level. This can have a significant dosimetric impact. The appropriate threshold level depends on lesion size and image reconstruction parameters. These effects should be carefully considered when using PET contour and/or volume information for radiotherapy applications.

Head and Neck Neoplasms↗

Dual energy CT attenuation correction methods for quantitative assessment of response to cancer therapy with PET/CT imaging.

We hypothesize that improved quantification for PET imaging of high atomic number materials can be achieved by combining low-dose x-ray imaging with dual energy CT for PET attenuation correction. Improved quantification of tracer uptake will lead to improved patient outcomes by providing more accurate information for therapeutic choices. Accurate PET/CT measurements of early response will be critical in determining the best cancer therapy option for each patient in a timely manner and in sparing patients the morbidity and cost of ineffective treatments. We first evaluate the potential errors in PET images arising from CT-based attenuation correction when iodine-based contrast is incorrectly classified as bone when forming the linear attenuation coefficient image. We then investigate two methods of reducing errors in the linear attenuation image: an approximate, but fast, hybrid classification/scaling algorithm and a model-based dual-energy CT method that incorporates the polyenergetic spectrum and a noise model in an iterative reconstruction method. Both methods are shown to reduce errors in the estimated linear attenuation coefficient image, but require further study to determine the effects of noise propagation if low-dose CT scans are used for the estimation of the linear attenuation image.

Algorithms↗

Correction methods for random coincidences in fully 3D whole-body PET: impact on data and image quality.

UNLABELLED: With the advantages of the increased sensitivity of fully 3-dimensional (3D) PET for whole-body imaging come the challenges of more complicated quantitative corrections and, in particular, an increase in the number of random coincidences. The most common method of correcting for random coincidences is the real-time subtraction of a delayed coincidence channel, which does not add bias but increases noise. An alternative approach is the postacquisition subtraction of a low-noise random coincidence estimate, which can be obtained either from a smoothed delayed coincidence sinogram or from a calibration scan or directly estimated. Each method makes different trade-offs between noise amplification, bias, and data-processing requirements. These trade-offs are dependent on activity injected, the local imaging environment (e.g., near the bladder), and the reconstruction algorithm. METHODS: Using fully 3D whole-body simulations and phantom studies, we investigate how the gains in noise equivalent count (NEC) rates from using a noiseless random coincidence estimation method are translated to improvements in image signal-to-noise ratio (SNR). The image SNR, however, depends on the image reconstruction method and the local imaging environment. RESULTS: We show that for fully 3D whole-body imaging using a particular set of scanners and clinical protocols, a low-noise estimate of random coincidences improves sinogram and image SNRs by approximately 15% compared with online subtraction of delayed coincidences. CONCLUSION: A 15% improvement in image SNR arises from a 32% increase in the NEC rate. Thus, scan duration can be reduced by 25% while still maintaining a constant total acquired NEC.

Algorithms↗

Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner.

We present a pragmatic approach to image reconstruction for data from the micro crystal elements system (MiCES) fully 3D mouse imaging positron emission tomography (PET) scanner under construction at the University of Washington. Our approach is modelled on fully 3D image reconstruction used in clinical PET scanners, which is based on Fourier rebinning (FORE) followed by 2D iterative image reconstruction using ordered-subsets expectation-maximization (OSEM). The use of iterative methods allows modelling of physical effects (e.g., statistical noise, detector blurring, attenuation, etc), while FORE accelerates the reconstruction process by reducing the fully 3D data to a stacked set of independent 2D sinograms. Previous investigations have indicated that non-stationary detector point-spread response effects, which are typically ignored for clinical imaging, significantly impact image quality for the MiCES scanner geometry. To model the effect of non-stationary detector blurring (DB) in the FORE+OSEM(DB) algorithm, we have added a factorized system matrix to the ASPIRE reconstruction library. Initial results indicate that the proposed approach produces an improvement in resolution without an undue increase in noise and without a significant increase in the computational burden. The impact on task performance, however, remains to be evaluated.

Animals↗

Distribution of 1-(2-deoxy-2-fluoro-beta-D-arabinofuranosyl) uracil in mice bearing colorectal cancer xenografts: rationale for therapeutic use and as a positron emission tomography probe for thymidylate synthase.

PURPOSE: In colorectal, breast, and head and neck cancers, response to 5-fluorouracil is associated with low expression of thymidylate synthase. In contrast, tumors with high expression of thymidylate synthase may be more sensitive to prodrugs such as 1-(2-deoxy-2-fluoro-beta-D-arabinofuranosyl) uracil (FAU) that are activated by thymidylate synthase. These studies were designed to evaluate FAU as a potential therapeutic and diagnostic probe. EXPERIMENTAL DESIGN: [18F]-FAU and [3H]-FAU were synthesized with >97% radiochemical purity. [3H]-FAU or [18F]-FAU was administered intravenously to severe combined immunodeficient mice bearing either HT29 (low thymidylate synthase) or LS174T (high thymidylate synthase) human colon cancer xenografts. Four hours after [3H]-FAU dosing, tissue distribution of total radioactivity and incorporation of 1-(2-deoxy-2-fluoro-beta-D-arabinofuranosyl) 5-methyluracil (FMAU), derived from thymidylate synthase activation of FAU, into tumor DNA was measured. Positron emission tomography (PET) images were obtained for 90 minutes after injection of [18F]-FAU. Thymidylate synthase activity was determined in vitro in tumors from untreated mice by [3H] release from [3H]dUMP. Each cell line was incubated in vitro with [3H]-FAU or [3H]-FMAU in the absence or presence of 5-fluoro-2'-deoxyuridine (FdUrd) and then was analyzed for incorporation of radiolabel into DNA. RESULTS: Thymidylate synthase enzymatic activity in LS174T xenografts was approximately 3.5-fold higher than in HT29 xenografts, and incorporation of radioactivity derived from [3H]-FAU into LS174T DNA was approximately 2-fold higher than into HT29 DNA. At 240 minutes, radioactivity derived from [3H]-FAU was approximately 2-fold higher in tumors than in skeletal muscle. At times up to 90 minutes, PET imaging detected only small differences in uptake of [18F]-FAU between the tumor types. Fluorine-18 in skeletal muscle was higher than in tumor for the first 90 minutes and plateaued earlier, whereas [18F] in tumor continued to increase during the 90-minute imaging period. For both cell lines in vitro, FdUrd decreased the rate of incorporation of [3H]-FAU into DNA, whereas the incorporation of [3H]-FMAU was increased. CONCLUSIONS: These results for FAU incorporation into DNA in vitro and in vivo further support clinical evaluation of FAU as a therapeutic agent in tumors with high concentrations of thymidylate synthase that are less likely to respond to 5-fluorouracil treatment. The high circulating concentrations of thymidine reported in mice may limit their utility in evaluating FAU as a PET probe.

Animals↗

Volumetric model and human observer comparisons of tumor detection for whole-body positron emission tomography.

RATIONALE AND OBJECTIVES: The performances of model and human observers were compared for detecting and localizing tumors in whole-body positron emission tomography imaging. Volumetric implementations of model observers were used instead of standard planar implementations to reproduce the common practice of using volumetric image displays to assess whole-body positron emission tomography images. MATERIALS AND METHODS: Observer studies with simulated data were used to compare three different acquisition protocols for an average patient size. Multiple realizations of simulated whole-body data with multiple added 1-cm diameter spherical lesions (targets) per image volume for efficiency were used. The location and contrast ratio of the targets were chosen randomly within ranges determined by initial calibration studies. Human observer studies were performed using a volumetric image display routinely used in clinical practice, and human observer detection performance was quantified using an alternate free-response operating characteristic analysis. The human detection performances were compared with the performances of volumetric implementations of the non-prewhitening matched filter and the channelized hotelling observer and also to the target contrast measured in the reconstructed image. RESULTS: Human observer detectability was generally well described as a linear function of these three figures of merit for the detection task considered. The best correlations (r = 0.96, rho = 0.98) were achieved with the channelized hotelling observer and non-prewhitening matched filter model observers. CONCLUSION: The use of volumetric model observers provides a means for quantitative comparisons of different protocols and also provides a useful tool for the optimization of key parameters in whole-body positron emission tomography imaging.

Humans↗

PET/CT scanner instrumentation, challenges, and solutions.

PET/CT scanners offer a hardware solution for aligning and viewing functional and anatomic images that is immune to many of the errors in strictly software registration techniques. Moreover, PET attenuation-corrected emission scans benefit from the use of the onboard CT for fast, low-noise attenuation correction. Along with the significant improved localization and reduced acquisition time, PET/CT scanners also introduce new instrumentation challenges ranging from patient movement to quantitative attenuation correction. This article provides an overview of current PET/CT scanner technology, a discussion of challenges faced by these systems, and pending solutions.

Humans↗

PET instrumentation.

PET is a nuclear medicine imaging modality and belongs to the family of emission CT, which also includes single-photon emission CT. PET measures the physiologic function inside the human body by measuring the concentration of a radioactively-labeled compound that is taken up by and accumulated in the body's organs. This article discusses the instrumentation used in PET.

Humans↗

A lesion detection observer study comparing 2-dimensional versus fully 3-dimensional whole-body PET imaging protocols.

UNLABELLED: We compared the impact of 2-dimensional (2D) and fully 3-dimensional (3D) acquisition modes on the performance of human observers in detecting and localizing tumors in whole-body (18)F-FDG images. METHODS: We selected protocols based on noise equivalent count (NEC) rates derived from a series of 2D and fully 3D whole-body patient and phantom acquisitions on a dual-mode PET scanner. The fully 3D peak NEC value for a standard 70-kg patient was achieved for an injected dose of approximately 444 MBq (12 mCi) assuming a 90-min delay before acquisition, whereas the 2D peak value was never reached. The protocols were therefore set to those corresponding to a 444-MBq injected dose in fully 3D and 2D and a 740-MBq (20 mCi) injected dose in 2D that was considered as the maximum allowable dose. We used a non-Monte Carlo simulator to generate multiple realizations of whole-body PET data based on the geometry of the mathematic cardiac torso phantom (MCAT) with accurate noise properties. Two-dimensional and fully 3D acquisition times were set to 5 min per bed position. Spherical 1-cm-diameter lesions (targets) with random locations and contrasts were distributed in different organs. The simulated 2D datasets were reconstructed using attenuation-weighted ordered-subsets expectation maximization ((AW)OSEM) and the fully 3D datasets were reconstructed with FORE+(AW)OSEM (FORE = Fourier rebinning). Five human observers located and ranked the targets using a volumetric display of the whole-body PET data to replicate the clinical practice. An alternate free-response operating characteristic (AFROC) analysis of the human observer reports was performed for each protocol and each organ separately. RESULTS: The 2D protocol corresponding to 740-MBq injected dose allowed the overall best detection performance. It was followed by the fully 3D acquisition at the peak fully 3D NEC rate from a 444-MBq injected dose. A 2D acquisition corresponding to a 444-MBq injected dose was ranked last. Differences in detection performance were organ specific. CONCLUSION: This study showed that, for this patient size and scanner type, the fully 3D acquisition mode allowed better or equivalent detection performance than the 2D mode for an injected dose corresponding to the peak fully 3D NEC rate. The 2D acquisition protocol combined with a higher injected dose resulted in the highest detectabilities.

Algorithms↗

X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scans have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of approximately 70 keV to attenuation coefficients at the PET energy of 511 keV. These translation methods are usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants; or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. In cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended.

Anatomy, Cross-Sectional↗

Evaluating image reconstruction methods for tumor detection in 3-dimensional whole-body PET oncology imaging.

UNLABELLED: We compare 3 image reconstruction algorithms for use in 3-dimensional (3D) whole-body PET oncology imaging. We have previously shown that combining Fourier rebinning (FORE) with 2-dimensional (2D) statistical image reconstruction via the ordered-subsets expectation-maximization (OSEM) and attenuation-weighted OSEM (AWOSEM) algorithms demonstrates improvements in image signal-to-noise ratios compared with the commonly used analytic 3D reprojection (3DRP) or FORE+FBP (2D filtered backprojection) reconstruction methods. To assess the impact of these reconstruction methods on detecting and localizing small lesions, we performed a human observer study comparing the different reconstruction methods. The observer study used the same volumetric visualization software tool that is used in clinical practice, instead of a planar viewing mode as is generally used with the standard receiver operating characteristic (ROC) methodology. This change in the human evaluation strategy disallowed the use of a ROC analysis, so instead we compared the fraction of actual targets found and reported (fraction-found) and also investigated the use of an alternative free-response operating characteristic (AFROC) analysis. METHODS: We used a non-Monte Carlo technique to generate 50 statistically accurate realizations of 3D whole-body PET data based on an extended mathematic cardiac torso (MCAT) phantom and with noise levels typical of clinical scans performed on a PET scanner. To each realization, we added 7 randomly located 1-cm-diameter lesions (targets) whose contrasts were varied to sample the range of detectability. These targets were inserted in 3 organs of interest: lungs, liver, and soft tissues. The images were reconstructed with 3 reconstruction strategies (FORE+OSEM, FORE+AWOSEM, and FORE+FBP). Five human observers reported (localized and rated) 7 targets within each volume image. An observer's performance accuracy with each algorithm was measured, as a function of the lesion contrast and organ type, by the fraction of those targets reported and by the area below the AFROC curve. This AFROC curve plots the fraction of reported targets at each rating threshold against the fraction of cases with (> or =1) similarly rated false reports. RESULTS: Images reconstructed with FORE+AWOSEM yielded the best overall target detection as compared with FORE+FBP and FORE+OSEM, although these differences in detectability were region specific. The FORE+FBP and FORE+AWOSEM algorithms had similar performances for liver targets. The FORE+OSEM algorithm performed significantly worse at target detection, especially in the liver. We speculate that this is the result of using an incorrect statistical model for OSEM and that the incorporation of attenuation weighting in AWOSEM largely compensates for this model inaccuracy. These results were consistent for both the fraction of actual targets found and the AFROC analysis. CONCLUSION: We demonstrated the efficacy of performing observer detection studies using the same visualization tools as those used in clinical PET oncology imaging. These studies demonstrated that the FORE+AWOSEM algorithm led to the best overall detection and localization performance for 1-cm-diameter targets compared with the FORE+OSEM and FORE+FBP algorithms.

Algorithms↗

An analytic study of the effects of attenuation on tumor detection in whole-body PET oncology imaging.

UNLABELLED: There has been considerable debate about the desirability of attenuation correction in whole-body PET oncology imaging. The advantages of attenuation correction are quantitative accuracy, whereas the perceived disadvantages are loss of contrast, noise amplification, and increased scanning time. In this work, we explain contrast changes between images reconstructed with and without attenuation correction. METHODS: To analytically explain both well-known and surprising phenomena in images reconstructed without attenuation correction, we performed a series of simulation studies, a phantom experiment, and a patient experiment. RESULTS: We showed that it is possible to calculate a priori the appearance of images reconstructed without attenuation correction. Compared with attenuation-corrected images, images without attenuation correction may have locally enhanced contrast in the abdomen or other regions of uniform attenuation, although the amount of enhancement varies with position in a complex manner. In regions of nonuniform attenuation, such as the thorax, it is possible that foci of increased tracer uptake disappear in images reconstructed without attenuation correction. The critical tracer concentration for this zero-contrast effect depends on the size, location, and density of the foci. Above the critical value, foci are visible in images with and without attenuation correction, whereas below the critical value, foci are visible in attenuation-corrected images but appear as photopenic regions in images without attenuation correction. CONCLUSION: Even though images without attenuation correction may be desired, these results suggest that all studies should at least be reconstructed with attenuation correction to avoid missing regions of elevated tracer uptake.

Female↗

Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels.

We present the results of utilizing aligned anatomical information from CT images to locally adjust image smoothness during the reconstruction of three-dimensional (3D) whole-body positron emission tomography (PET) data. The ability of whole-body PET imaging to detect malignant neoplasms is becoming widely recognized. Potentially useful, however, is the role of whole-body PET in quantitative estimation of tracer uptake. The utility of PET in oncology is often limited by the high level of statistical noise in the images. Reduction in noise can be obtained by incorporating a priori image smoothness information from correlated anatomical information during the reconstruction of PET data. A combined PET/CT scanner allows the acquisition of accurately aligned PET and x-ray CT whole-body data. We use the Fourier rebinning algorithm (FORE) to accurately convert the 3D PET data to two-dimensional (2D) data to accelerate the image reconstruction process. The 2D datasets are reconstructed with successive over-relaxation of a penalized weighted least squares (PWLS) objective function to model the statistics of the acquisition, data corrections, and rebinning. A 3D voxel label model is presented that incorporates the anatomical information via the penalty weights of the PWLS objective function. This combination of FORE + PWLS + labels was developed as it allows for both reconstruction of 3D whole-body data sets in clinically feasible times and also the inclusion of anatomical information in such a way that convergence can be guaranteed. Since mismatches between anatomical (CT) and functional (PET) data are unavoidable in practice, the labels are 'blurred' to reflect the uncertainty associated with the anatomical information. Simulated and experimental results show the potential advantage of incorporating anatomical information by using blurred labels to calculate the penalty weights. We conclude that while the effect of this method on detection tasks is complicated and unclear, there is an improvement on the estimation task.

Computer Simulation↗

Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET.

UNLABELLED: The noise equivalent count (NEC) rate index is used to derive guidelines on the optimal injected dose to the patient for 2-dimensional (2D) and 3-dimensional (3D) whole-body PET acquisitions. METHODS: We performed 2D and 3D whole-body acquisitions of an anthropomorphic phantom modeling the conditions for (18)F-FDG PET of the torso and measured the NEC rates for different activity levels for several organs of interest. The correlations between count rates measured from the phantom and those from a series of whole-body patient scans were then analyzed. This analysis allowed validation of our approach and estimation of the injected dose that maximizes NEC rate as a function of patient morphology for both acquisition modes. RESULTS: Variations of the phantom and patient prompt and random coincidence rates as a function of single-photon rates correlated well. On the basis of these correlations, we demonstrated that the patient NEC rate can be predicted for a given single-photon rate. Finally, we determined that patient single-photon rates correlated with the mean dose per weight at acquisition start when normalized by the body mass index. This correlation allows modifying the injected dose as a function of patient body mass index to reach the peak NEC rate in 3D mode. Conversely, we found that the peak NEC rates were never reached in 2D mode within an acceptable range of injected dose. CONCLUSION: The injected dose was adapted to patient morphology for 2D and 3D whole-body acquisitions using the NEC rate as a figure of merit of the statistical quality of the sinogram data. This study is a first step toward a more comprehensive comparison of the image quality obtained using both acquisition modes.

Fluorodeoxyglucose F18↗

Development of a single detector ring micro crystal element scanner: QuickPET II.

This article describes a single ring version of the micro crystal element scanner (MiCES) and investigation of its spatial resolution imaging characteristics for mouse positron emission tomography (PET) imaging. This single ring version of the MiCES system, referred to as QuickPET II, consists of 18 MiCE detector modules mounted as a single ring in a vertical gantry. The system has a 5.76-cm transverse field of view and a 1.98-cm axial field of view. In addition to the scanner and data acquisition system, we have developed an iterative reconstruction that includes a model of the system's detector response function. Evaluation images of line sources and mice have been acquired. Using filtered backprojection, the resolution for a reconstructed line source has been measured at 1.2 mm full width at half maximum. F-18-2-fluoro-2-deoxyglucose mouse PET images are provided. The result shows that QuickPET II has the imaging characteristics to support high-resolution, static mouse PET studies using 18-F labeled compounds.

Animals↗