PubMed Health⌕ Search

Biomedical subjects

Paul J Foster

Publications and source records attributed to Paul J Foster.

At least 19 recordsLinked to original sources

Comparison of the scanning peripheral anterior chamber depth analyzer and the modified van Herick grading system in the assessment of angle closure.

PURPOSE: To compare the performance of the scanning peripheral anterior chamber depth analyzer (SPAC) and the modified van Herick grading system in the assessment of angle closure, using gonioscopy as the reference standard. DESIGN: Prospective comparative study. PARTICIPANTS: One hundred twenty phakic subjects (53 with primary angle closure and 67 with open angles) with no history of laser or intraocular surgery. METHODS: The modified van Herick grading system was used to grade the peripheral anterior chamber depth (ACD) clinically. The SPAC was used to assess ACD, and this was graded categorically as S (suspect angle closure), P (potential angle closure), or N (normal) and numerically from 1 to 12. One randomly selected eye of each subject underwent examination with the modified van Herick grading, SPAC, Goldmann applanation tonometry, optic disc examination, and gonioscopy. The SPAC measurements, modified van Herick grades (0%, 5%, 15%, 25%, 40%, 75%, and > or =100% of corneal thickness), and gonioscopy (graded as narrow or open) were correlated using the Spearman correlation coefficient. The receiver operating characteristics of the 2 methods to detect angle closure also were compared. MAIN OUTCOME MEASURES: Grading of ACD by the SPAC, the modified van Herick system, and gonioscopic grading of the angle. RESULTS: The SPAC results correlated well with the modified van Herick grading system (categorical grade, r = 0.527; numerical grade, r = 0.542; P<0.0001). For eyes graded as having narrow angles by gonioscopy, the area under the curve (AUC) for SPAC categorical grade S or P was 0.790; sensitivity and specificity were 84.9% and 73.1%, respectively. For the modified van Herick grading system, using a cutoff of peripheral ACD < or = 25% corneal thickness, the AUC was 0.872 and sensitivity and specificity were 84.9% and 89.6%. Compared with gonioscopy that found 53 of 120 cases of narrow angles, the SPAC graded more eyes as having narrow angles (63/120) than the modified van Herick system (52/120). CONCLUSIONS: The SPAC correlated well with the modified van Herick system in grading peripheral ACD. However, the SPAC appeared to overestimate the proportion of eyes with narrow angles relative to gonioscopy and the modified van Herick grading system.

Adult↗

Laser peripheral iridotomy in primary angle-closure suspects: biometric and gonioscopic outcomes: the Liwan Eye Study.

PURPOSE: To assess the immediate effect of laser peripheral iridotomy (LPI) and mechanisms of angle closure in a population-based study of primary angle closure (PAC) suspects. DESIGN: Prospective interventional study. PARTICIPANTS: People identified as PAC suspects aged 50 to 79 years from a population-based survey in Guangzhou, China. INTERVENTION: Laser peripheral iridotomy was performed in 1 randomly selected eye. Examinations were carried out before and 2 weeks after the intervention. MAIN OUTCOME MEASURES: Intraocular pressure (IOP), ultrasound biometry, optical pachymetry, and gonioscopy. RESULTS: A total of 72 people with bilateral suspected PAC participated in the study. Mean IOP decreased by 3 mmHg (P<0.001), but axial anterior chamber depth did not change significantly (P = 0.784) after LPI. Median limbal anterior chamber depth increased from 15% to 25% of peripheral corneal thickness (P<0.001, Wilcoxon signed-rank test). Median iridotrabecular angle width increased from 0 degrees to 10 degrees in the superior quadrant and from 10 degrees to 30 degrees in the inferior quadrant (P<0.001). Nevertheless, 14 eyes (19.4%) still had 3 or more quadrants in which the posterior (usually pigmented) trabecular meshwork could not be seen after laser iridotomy. CONCLUSIONS: This study confirms that LPI results in a significant increase in the angle width in Chinese people with narrow angles. However, one fifth of eyes had residual angle closure after LPI. Although this report confirms that iridotomy widens the anterior chamber angle in most PAC suspects, long-term prospective studies with a larger sample size are required to determine if the risks of PAC glaucoma and other related pathologic sequelae are reduced after prophylactic LPI and to investigate the risk-to-benefit ratio before recommending widespread use of prophylactic LPI in this population.

Aged↗

Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.

OBJECTIVE: To evaluate noncontact anterior segment optical coherence technology (AS-OCT) as a qualitative method of imaging the anterior chamber angle and to determine its ability to detect primary angle closure when compared with gonioscopy in Asian subjects. DESIGN: Prospective observational case series. PARTICIPANTS: Two hundred three subjects were recruited from glaucoma clinics in Singapore with diagnoses of primary angle closure, primary open-angle glaucoma, ocular hypertension, or cataract. Both eyes (if eligible) of each patient were included in the study. Exclusion criteria were pseudophakia or previous glaucoma surgery. METHODS: Images of the nasal, temporal, and inferior angles were obtained with AS-OCT in dark and then light conditions. Gonioscopic angle width was graded using the Spaeth classification for each quadrant in low lighting conditions. MAIN OUTCOME MEASURES: Angle closure was defined by AS-OCT as contact between the peripheral iris and angle wall anterior to the scleral spur and by gonioscopy as a Spaeth grade of 0 degree (posterior trabecular meshwork not visible). Comparison of the 2 methods in detecting angle closure was done by eye and by individual. Sensitivities and specificities of AS-OCT were calculated using gonioscopy as the reference standard. RESULTS: Complete data were available for 342 eyes of 200 patients. Of the patients, 70.9% had a clinical diagnosis of treated or untreated primary angle closure. Angle closure in > or =1 quadrants was detected by AS-OCT in 142 (71%) patients (228 [66.7%] eyes) and by gonioscopy in 99 (49.5%) patients (152 [44.4%] eyes). The inferior angle was closed more frequently than the nasal or temporal quadrants using both AS-OCT and gonioscopy. When performed under dark conditions, AS-OCT identified 98% of those subjects found to have angle closure on gonioscopy (95% confidence interval [CI], 92.2-99.6) and led to the characterization of 44.6% of those found to have open angles on gonioscopy to have angle closure as well. With gonioscopy as the reference standard, specificity of AS-OCT in the dark was 55.4% (95% CI, 45.2-65.2) for detecting individuals with angle closure. CONCLUSION: Anterior segment OCT is a rapid noncontact method of imaging angle structures. It is highly sensitive in detecting angle closure when compared with gonioscopy. More persons are found to have closed angles with AS-OCT than with gonioscopy.

Adult↗

Imaging of trabeculectomy blebs using anterior segment optical coherence tomography.

OBJECTIVE: To image trabeculectomy blebs using anterior segment optical coherence tomography (AS-OCT). DESIGN: Prospective cross-sectional study. PARTICIPANTS: Fifty-five patients who had previously undergone trabeculectomy surgery. METHODS: All blebs were imaged with a prototype of the AS-OCT. Standardized color monophotographs of blebs were also obtained. Blebs were assessed for the following qualitative features: bleb height, thickness of the conjunctiva in the bleb wall, presence of cystic spaces within the bleb wall, apposition of the scleral flap to underlying sclera, and patency of the internal ostium. MAIN OUTCOME MEASURES: For blebs with preoperative intraocular pressure (IOP) > 18 mmHg with or without ocular hypotensive medication, success was defined as last recorded IOP< or =18 mmHg without topical glaucoma medication. For blebs with preoperative IOP< or =18 mmHg with ocular hypotensive medication, success was defined last recorded IOP< or =18 mmHg with cessation of ocular hypotensive medication. For blebs with preoperative IOP< or =18 mmHg without ocular hypotensive medication, a 20% drop in IOP with no ocular hypotensive medication was accepted as success. RESULTS: Seventy-eight blebs in eyes of 55 patients were imaged. There were 32 (58.2%) men and the mean age was 68.9+/-11.5 years. Fifty-seven (73.1%) blebs were classified as successful. Anterior segment optical coherence tomography identified the following bleb characteristics: total bleb height, bleb cavity, bleb wall thickness, tangential and radial dimensions, scleral flap thickness, and patency of the internal ostium. The majority of successful blebs displayed thickening of the bleb wall. Failed blebs were mostly low and were characterized by ostial occlusion, apposition of conjunctiva-episclera to sclera or apposition of the scleral flap to its bed. Thickening of the bleb wall was typically absent. CONCLUSIONS: AS-OCT is a promising tool to image trabeculectomy blebs. It was able to demonstrate features of bleb morphology not visible with the slit lamp.

Aged↗

Detection of narrow angles and established angle closure in Chinese residents of Singapore: potential screening tests.

PURPOSE: To assess the performance of peripheral and central anterior chamber depth (ACD) measurements, and autorefraction, in identifying Chinese people with occludable drainage angles or established primary angle closure. DESIGN: Population-based cross-sectional analysis. METHODS: Subjects aged 40 years and older were drawn from a representative sample of Chinese Singaporean residents. Limbal chamber depth (LCD) was estimated and central ACD was measured using optical pachymetry and ultrasound. An autorefraction was taken for all subjects. Angle width and the presence of peripheral anterior synechiae were determined by gonioscopy. Receiver operating characteristic curves were generated to show the performance of these tests in detecting occludable angles. RESULTS: A total of 1090 subjects were examined. The prevalence of occludable angles was 6.5%. LCD measurement performed best in detecting occludable angles (area under the curve [AUC] 0.904, 95% confidence interval [CI] 0.870, 0.937). Optical pachymetry and ultrasound measurement of ACD performed less well (AUC 0.859 and 0.810, respectively), and autorefraction performed poorly in detecting occludable angles (AUC 0.632). LCD also gave the best performance in detecting primary angle closure (AUC 0.782, 95% CI 0.727, 0.837). CONCLUSIONS: Limbal LCD estimation outperforms other methods of measuring ACD as a screening tool for the detection of occludable drainage angles in the Chinese population of Singapore.

Adult↗

Effect of trabeculectomy on lens opacities in an East Asian population.

OBJECTIVE: To examine the progression of lens opacity in Asian people after trabeculectomy and determine associated risk factors. METHODS: This was an observational case series of 243 people aged 36 to 82 years. Trabeculectomy was performed on 1 eye of each subject. Lens opacity was measured yearly using the Lens Opacification Classification System III. The main outcome measure was worsening of lens opacity defined as an increase of 2 or more Lens Opacification Classification System III units in any of the 3 lens regions, nuclear, cortical, and posterior subcapsular. Risk of progression was evaluated using logistic regression models. RESULTS: Data for 177 people were analyzed. One hundred seventeen (66%) of 177 subjects showed progression in opacity in any lens region at 3 years. Seventy-seven (66%) of 117 of those who progressed did so during the first year. Of these, 63 (82%) of 77 had lens opacity in the posterior subcapsular region. Factors associated with progression of posterior-subcapsular lens opacity at 1 year were diabetes (odds ratio, 2.4; 95% confidence interval, 1.0-5.4), use of antiglaucoma medication, dosage of topical steroid postoperatively, and being operated on by a trainee surgeon (odds ratio, 2.3; 95% confidence interval, 1.0-5.2). CONCLUSIONS: Trabeculectomy is associated with progression of lens opacity predominantly in the posterior subcapsular region. Modification of risk factors such as postoperative steroid use may delay progression.

Adult↗

Hypermetropia, axial length, and hypertension: the Tanjong Pagar survey.

PURPOSE: To examine the relationship among hypermetropia, axial length, and hypertension in a Chinese population. DESIGN: Population-based cross-sectional study. METHODS: This study included 1213 Chinese individuals aged 40 to 81 years. Hypertension was defined as systolic blood pressure > or =140 mm Hg, diastolic blood pressure > or =90 mm Hg, or self-report history of antihypertension treatment. Refraction was determined with an autorefractor and refined subjectively. A-mode ultrasound scanning was used to measure axial length. RESULTS: The crude odds ratio of hypertension was 2.5 (95% CI, 1.4-4.6) for moderate hypermetropia (> or =+2.00 spheric equivalent diopters) vs high myopia (< or =-6.00 diopters), and 1.4 (95% CI, 0.9-2.1) for highest vs lowest axial length quintile. These associations were no longer significant after adjustment for age, gender, education, housing type, and income. CONCLUSIONS: These data provide no evidence that hypermetropia or shorter axial length is associated independently with hypertension in Chinese individuals.

Adult↗

Peripapillary retinal nerve fiber layer thickness variations with myopia.

PURPOSE: To determine the relationship between peripapillary retinal nerve fiber layer (RNFL) thickness and myopia using optical coherence tomography (OCT). DESIGN: Prospective observational case series. METHODS: One hundred thirty-two young males with myopia (spherical equivalent [SE], -0.50 to -14.25 diopters) underwent ophthalmic examination of one randomly selected eye. Optical coherence tomography (OCT-1, version 4.1) was performed by a single operator using circular scans concentric with the optic disc with scan diameters of 3.40 mm, 4.50 mm, and 1.75 x vertical disc diameter (VDD). For each scan diameter, mean peripapillary RNFL thickness was calculated. Statistical analysis comprised repeated-measurements analysis and Pearson correlation. RESULTS: Mean peripapillary RNFL thickness did not correlate with SE for the 3.40-mm (r = -0.11, P = 0.22), 4.50-mm (r = -0.103, P = 0.24), or 1.75xVDD (r = -0.08, P = 0.36) OCT scan diameters. Neither did mean peripapillary RNFL thickness correlate with axial length for the 3.40-mm (r = -0.04, P = 0.62), 4.50-mm (r = 0.03, P=0.75), or 1.75xVDD (r = -0.02, P = 0.78) scan diameters. Mean peripapillary RNFL thicknesses for the 3.40-mm, 4.50-mm, and 1.75xVDD scans were 101.1+/-8.2 microm (95% confidence interval [CI], 99.4-102.8), 78.9+/-8.2 microm (95% CI, 77.5-80.3), and 97.5+/-10.9 microm (95% CI, 95.6-99.4), respectively. CONCLUSIONS: Mean peripapillary RNFL thickness did not vary with myopic SE or axial length for any OCT scan diameter investigated. Retinal NFL thickness measurements may be a useful parameter to assess and monitor glaucoma damage in myopic subjects.

Adult↗

Prevalence and clinical characteristics of glaucoma in adult Chinese: a population-based study in Liwan District, Guangzhou.

PURPOSE: To assess the prevalence and mechanism of glaucoma in adults living in an urban area of southern China. METHODS: Random clustering sampling was used to identify adults aged 50 years and over in Liwan District, Guangzhou. Glaucoma was diagnosed with the ISGEO (International Society of Geographical and Epidemiological Ophthalmology) classification scheme. All subjects underwent gonioscopy. RESULTS: In the study, 1504 subjects (75.3% participation rate) were examined, with a crude prevalence of all glaucoma of 3.8% (95% confidence interval [CI], 2.8%-4.8%). Primary open-angle glaucoma (POAG) was found in 2.1% (95% CI, 1.4%-2.8%) and primary angle-closure glaucoma (PACG) in 1.5% (95% CI, 0.8%-2.1%). The prevalence of all glaucoma was significantly higher in older people and men. CONCLUSIONS: POAG was more common than PACG in this southern Chinese population, with rates similar to those reported in Chinese Singaporeans. The age-adjusted rate of POAG was similar to that found in European-derived populations, but PACG was more common among Chinese, indicating that there is a large burden of glaucoma in the Chinese people.

Age Distribution↗

Gonioscopy in adult Chinese: the Liwan Eye Study.

PURPOSE: To assess gonioscopic characteristics of the drainage angle in adult Chinese in an urban area of southern China. METHODS: Clustered random sampling was used to select adults aged 50 years and older in Liwan District, Guangzhou. Gonioscopy was performed on all the subjects. The geometric angle width was graded in the superior and inferior quadrants, according to the Spaeth system. In addition, apparent and true iris insertion was classified in four quadrants with static and dynamic gonioscopy. The peripheral iris profile was described as steep, regular, concave, and plateau. Data are presented for all phakic right eyes. Secondary or iatrogenic cases were excluded in the analysis of peripheral anterior synechiae (PAS). RESULTS: Among 1405 participants in the study, data from 1330 (95%) right eyes were available for analysis. Iridotrabecular angles (ITA) < or =20 degrees were present in 36.9% (95% CI: 34.3%-40.0%) of eyes superiorly and in 27.9% (95% CI: 25.5%-30.4%) inferiorly. Narrower ITAs were more common in the older people (sex-adjusted odds ratio [OR] = 1.1 per year of life; P < 0.001) and the women (age-adjusted OR = 2.5, P < 0.001). Apparent iris insertion of grade A or B (with pigmented trabecular meshwork not visible) by quadrant was observed in 27.2% superiorly, 12.0% nasally, 7.7% inferiorly, and 14.2% temporally. Narrow angles (in which pigmented trabecular meshwork was not visible in three or more quadrants) were identified in 11.0% (95% CI: 9.3%-12.7%) of right eyes. Overall, 33.3% of eyes had a steep iris profile, 54.2% were normal, 2.7% were concave, and 10.1% were graded plateau. PAS were seen in 30 of 146 (20.5%) eyes with narrow angles and in 7 (0.6%) of 1184 eyes with angles that did not meet criteria for narrow angles. PAS were more likely with narrower angles, with 0%, 0.3%, and 1.9% of eyes with a mean ITA of 40 degrees, 30 degrees, and 20 degrees, respectively, having PAS as opposed to 12.6% and 27.5% for those with ITA 10 degrees and 0 degrees , respectively. CONCLUSIONS: Ten percent of this population of southern Chinese persons 50 years of age and older had narrow angles. PAS were present in one fifth of these people. From these cross-sectional data, it is unclear which of these individuals are at highest risk of the development of primary angle-closure (PAC) glaucoma. Longitudinal studies are necessary to determine appropriate strategies for preventing this potentially blinding outcome.

Aged↗

Anterior chamber depth and the risk of primary angle closure in 2 East Asian populations.

OBJECTIVE: To evaluate the risk of peripheral anterior synechiae (PAS) and glaucomatous optic neuropathy attributable to primary angle closure at varying anterior chamber depths (ACDs) in two East Asian populations. METHODS: Participants 40 years and older were from 2 population-based glaucoma surveys in Mongolia and Singapore. Central ACD was measured by optical pachymetry. Presence of PAS was determined by dynamic gonioscopy. Cases with secondary PAS were excluded. Glaucomatous optic neuropathy was diagnosed in subjects with structural and functional evidence of glaucoma. RESULTS: A total of 2032 subjects, consisting of 942 Mongolians and 1090 Chinese Singaporeans, were included in this study. A logistic model of the relationship between ACD and PAS among Singaporeans showed a consistent, incremental increase in PAS across the entire range of ACD. In deeper anterior chambers the rate of PAS exceeded that seen in Mongolians. In Mongolians, there was a clear threshold for ACD (2.4 mm) at or above which PAS were very uncommon. With ACD less than 2.4 mm, the rate of PAS rose rapidly to overtake that seen in Singaporeans. CONCLUSIONS: Shallow anterior chambers are a significant risk factor for angle closure in East Asians, although the nature of the association is specific to the individual population. There was a trend toward higher rates of glaucomatous optic neuropathy in people with the shallowest anterior chambers.

Adult↗

Optic disk ovality as an index of tilt and its relationship to myopia and perimetry.

PURPOSE: To examine the association of optic disk ovality with myopic refractive error, axial length, and the visual field. DESIGN: Prospective observational case series. METHODS: The study included 150 randomly recruited male subjects with myopia. In all cases, one eye was randomly selected, and subjective refraction, slit-lamp examination, applanation tonometry, gonioscopy, A-scan ultrasonography, funduscopy, and color optic disk stereo photography were performed. Disk ovality was assessed using the ratio of minimum to maximum disk diameter (index of tilt). A ratio of < or = 0.8 was considered as significant disk tilt. Visual fields were tested using static automated threshold perimetry with two methods of optical correction: trial lenses and contact lenses. RESULTS: Of the total sample, 137 subjects completed the study. Mean age was 21.2 +/- 1.1 year, and mean spherical equivalent was -6.36 +/- 3.56 diopters. Mean ovality ratio was 0.83 +/- 0.09; 55 subjects (40.2%) had significant tilted optic disks. Greater optic disk ovality (tilt) correlated with greater myopia (P = .009) and longer axial length (P = .009); 95.6% of subjects had normal visual fields with both methods of optical correction. Using multiple linear regression analysis, greater tilt was independently related to a higher mean defect on testing with trial lenses (P < .01). CONCLUSIONS: Increased optic disk tilt was associated with higher myopia and reduced sensitivity on field testing. These factors are important in the assessment of glaucoma in patients with myopia.

Adult↗

Use of optical coherence tomography to assess variations in macular retinal thickness in myopia.

PURPOSE: To investigate the variation in macular retinal thickness in otherwise normal young Asian myopic subjects by using optical coherence tomography (OCT). METHODS: One hundred thirty ophthalmically normal men 19 to 24 years of age with myopia (spherical equivalent, -0.25 to -14.25 D) underwent examination of one randomly selected eye. Visual acuity, refraction, slit lamp examination, applanation tonometry, gonioscopy, A-scan ultrasound, fundus examination, visual field testing, and optic disc photography were performed. Exclusion criteria were visual acuity worse than 20/30, previous intraocular surgery, intraocular pressure >21 mm Hg, or other ocular diseases. Three horizontal transfixation and three vertical transfixation OCT scans (ver.4.1; Carl Zeiss Meditec, Dublin, CA) of 6 mm each were conducted on each eye by a single operator. Neurosensory retinal thicknesses at 100 points along each scan were measured, and the overall average, maximum, and minimum retinal thicknesses were analyzed by simple linear regression and analysis of variance. RESULTS: The average macular retinal thickness (overall) was 230.9 +/- 10.5 microm and was not significantly related to the degree of myopia. The mean maximum retinal thickness (at the parafovea) was 278.4 +/- 13.0 microm, and correlated negatively with axial length (P = 0.03). The mean minimum retinal thickness (at the foveola) was 141.1 +/- 19.1 microm, and this was positively correlated with axial length (P = 0.015) and spherical equivalent (P = 0.0002). The retina was thicker at the superior and nasal parafovea compared to the inferior or temporal parafovea. CONCLUSIONS: Average retinal thickness of the macula does not vary with myopia. However, the parafovea was thinner and the fovea thicker with myopia.

Adult↗

Molecular analysis of the myocilin gene in Chinese subjects with chronic primary-angle closure glaucoma.

PURPOSE: Mutations in the myocilin (MYOC) gene have been implicated in juvenile as well as late-onset primary open-angle glaucoma (POAG). Overall, MYOC mutations account for 3% to 5% of cases of POAG worldwide, making it the most significant gene identified so far in glaucoma. Although there are some similarities in the phenotype of POAG and in particular chronic primary angle-closure glaucoma (PACG), little is known about the role of MYOC in the causation of PACG. To address this, the MYOC gene was screened in a cohort of 106 patients with chronic PACG. METHODS: Genomic DNA was extracted from leukocytes of the peripheral blood and exons 1 to 3 of the MYOC gene were PCR amplified and subjected to bidirectional sequencing and analysis. RESULTS: One hundred six patients with chronic PACG of Chinese ethnicity were studied. Sequencing of the MYOC gene in these patients revealed eight sequence variants. Of these, one was a nonsense change, three were missense changes, two were synonymous codon changes, and two were changes in noncoding sequences. These included the Arg46Stop and Thr353Ile mutations, which have been reported in individuals with POAG. However, all the sequence alterations identified have been found in normal Chinese subjects. CONCLUSIONS: The results of this study do not support a role for MYOC mutations in the pathogenesis of chronic PACG in the Chinese.

Aged↗