PubMed Health⌕ Search

Biomedical subjects

Paul Klahr

Publications and source records attributed to Paul Klahr.

2 recordsLinked to original sources

Displacement-based binning of time-dependent computed tomography image data sets.

Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment have recently used a technique developed for cardiac CT imaging to track respiratory-induced anatomical motion and to sort images according to the phase of the respiratory cycle they represent. Here we propose a method of generating CT images that accounts for respiratory-induced anatomical motion on the basis of displacement, i.e., displacement-binned CT image sets. This technique has shown great promise, however, it is not fully supported by currently used CT image reconstruction software. As an interim solution, we have developed a method for extracting displacement-binned CT image data sets from data sets assembled on the basis of a prospectively determined breathing phase acquired on a multislice helical CT scanner. First, the projection data set acquired from the CT scanner was binned at small phase intervals before reconstruction. The manufacturer's software then generated image sets identified as belonging to particular phases of the respiratory cycle. All images were then individually correlated to the displacement of an external fiducial marker. Next, CT image data sets were resorted on the basis of the displacement and assigned an appropriate phase. Finally, displacement-binned image data sets were transferred to a treatment-planning system for analysis. Although the technique is currently limited by the phase intervals allowed by the CT software, some improvement in image reconstruction was seen, indicating that this technique is useful at least as an interim measure.

Algorithms↗

Gated CT imaging using a free-breathing respiration signal from flow-volume spirometry.

Respiration-induced tumor motion is known to cause artifacts on free-breathing spiral CT images used in treatment planning. This leads to inaccurate delineation of target volumes on planning CT images. Flow-volume spirometry has been used previously for breath-holds during CT scans and radiation treatments using the active breathing control (ABC) system. We have developed a prototype by extending the flow-volume spirometer device to obtain gated CT scans using a PQ 5000 single-slice CT scanner. To test our prototype, we designed motion phantoms to compare image quality obtained with and without gated CT scan acquisition. Spiral and axial (nongated and gated) CT scans were obtained of phantoms with motion periods of 3-5 s and amplitudes of 0.5-2 cm. Errors observed in the volume estimate of these structures were as much as 30% with moving phantoms during CT simulation. Application of motion-gated CT with active breathing control reduced these errors to within 5%. Motion-gated CT was then implemented in patients and the results are presented for two clinical cases: lung and abdomen. In each case, gated scans were acquired at end-inhalation, end-exhalation in addition to a conventional free-breathing (nongated) scan. The gated CT scans revealed reduced artifacts compared with the conventional free-breathing scan. Differences of up to 20% in the volume of the structures were observed between gated and free-breathing scans. A comparison of the overlap of structures between the gated and free-breathing scans revealed misalignment of the structures. These results demonstrate the ability of flow-volume spirometry to reduce errors in target volumes via gating during CT imaging.

Biophysical Phenomena↗