PubMed Health⌕ Search

Biomedical subjects

Paul R Haddad

Publications and source records attributed to Paul R Haddad.

At least 19 recordsLinked to original sources

Comprehensive two-dimensional liquid chromatography.

Having nearly exhausted the possibilities for generating peak capacity through improvements in column technology, chromatographers are increasingly looking to alternative ways of maximising chromatographic separation. In recent years there has been increasing activity in the field of comprehensive multidimensional separations to meet analysis demands. Comprehensive two-dimensional liquid chromatography (LCxLC) approaches offer high peak capacity which leads to significantly improved analytical performance over single-column liquid chromatography. There are several closely related avenues available for achieving an LCxLC separation and this review pays special attention to the different valve-based interfaces that have been used to comprehensively couple the first and second dimension columns in LCxLC systems. A brief discussion of column choices for selected applications and the conditions employed is also presented.

Journal Article↗

Temperature profiles and heat dissipation in capillary electrophoresis.

While temperature control is usually employed in capillary electrophoresis (CE) to aid heat dissipation and provide acceptable precision, internal electrolyte temperatures are almost never measured. In principle, this limits the accuracy, repeatability, and method robustness. This work presents a fundamental study that combines the development of new equations characterizing temperature profiles in CE with a new method of temperature determination. New equations were derived from first principles relating the mean, axial, and inner wall electrolyte temperatures (T(Mean), T(Axis), T(Wall)). T(Mean) was shown to occur at a distance 1/ radical3 times the internal radius of the capillary from the center of the capillary and to be a weighted average of (2/3)T(Axis) and (1/3)T(Wall). Conductance (G) and electroosmotic mobility (mu(EOF)) can be used to determine T(Mean) and T(Wall), respectively. Extrapolation of curves of mu(EOF) versus power per unit length (P/L) at different temperatures was used to calibrate the variation of mu(EOF) with temperature (T), free from Joule heating effects. mu(EOF) increased at 2.22%/ degrees C. The experimentally determined temperatures using mu(EOF) agreed to within 0.2 degrees C with those determined using G. The accuracy of G measurements was confirmed independently by measuring the electrical conductivity (kappa) of the bulk electrolyte over a range of temperatures and by calculating the variation of G with T from the Debye-Hückel-Onsager equation. T(Mean) was found to be up to 20 degrees C higher than the external temperature under typical conditions using active air-cooling and a 74.0-microm-internal diameter (di) fused-silica capillary. A combination of experimentally determined and calculated temperatures enables a complete temperature profile for a fused-silica capillary to be drawn and the thickness of the stationary air layer to be determined. As an example, at P/L = 1.00 Wm(-1), the determined radial temperature difference across the electrolyte was 0.14 degrees C; the temperature difference across the fused-silica wall was 0.17 degrees C, across the poly(imide) coating was 0.13 degrees C, and across the stationary air layer was 2.33 degrees C.

Journal Article↗

Analyte-stationary phase interactions in ion-exclusion chromatography.

The currently accepted analyte-stationary phase interactions occurring in ion-exclusion chromatography are re-examined. In particular, the requirement for the existence of a Donnan membrane separating the flowing, interstitial eluent from the static, occluded, liquid acting as the stationary phase is scrutinized, together with the role of hydrophobic adsorption effects in the retention of aromatic analytes. Plots showing the interconversion of the column between the analyte and eluent forms are used to highlight some shortcomings of the currently accepted mechanism for ion-exclusion chromatography. An alternative retention mechanism for ion-exclusion chromatography is proposed, based on the presence of a potential well at the surface of the fully functionalized styrene-divinylbenzene co-polymer stationary phase. Analytes diffuse into the potential well under the effects of concentration gradients, and undergo repulsion effects from the fixed charges inside the pores. The net contributions of these two opposing processes determine the degree to which an analyte is retained on the stationary phase. Negligible hydrophobic adsorption of the analyte onto the polymeric resin supporting the stationary phase is considered to occur.

Acetic Acid↗

Variation of zeta-potential with temperature in fused-silica capillaries used for capillary electrophoresis.

The temperature variation of electroosmotic mobility corrected for the effects of Joule heating (muEOF0) was employed to investigate the variation of the zeta-potential (zeta) with temperature in fused-silica capillaries. Experimentally determined values for zeta increased at 0.39% per degrees C, a rate that is about four to five times smaller than reported previously. Experimentally determined values of zeta were directly proportional to the absolute temperature although values were also influenced slightly by changes to the dielectric constant. It was found that the effective charge density at the inner surface of the capillary was independent of temperature.

Electrophoresis, Capillary↗

Preparation and characterisation of dual-layer latex-coated columns for open-tubular capillary electrochromatographic preconcentration of cations combined in-line with their separation by capillary electrophoresis.

A dual-layer ion-exchange latex-coated column was prepared and characterised for on-capillary preconcentration of cations using an open-tubular ion-exchange CEC format. After preconcentration, the analyte cations were eluted with a transient isotachophoretic gradient and separated by CE. The latex double layer was established by first coating the negatively charged wall of the capillary with a layer of cationic quaternary ammonium anion-exchange Dionex AS5A latex particles (60 nm diameter), and then coating a layer of anionic sulphonated cation-exchange Dionex CS3 latex particles (300 nm diameter) onto the underlying AS5A layer. The adhesion of layers is based on electrostatic attractions. Several dual-layer capillaries were characterised for their EOF and ion-exchange capacity and this showed that coatings could be prepared reproducibly by a simple flushing procedure. The dual-layer columns exhibited a moderate, pH-independent EOF (ca. 26 x 10(-9 )m2V(-1)s(-1)) and an ion-exchange capacity of 57 microequiv./g (or 2.69 nequiv./column). Using an 8 cm length of coated capillary combined with a 72 cm length of untreated capillary, a method for on-line preconcentration and separation of monovalent organic bases, alkali metal ions and alkaline earth metal ions by CE was developed. Recoveries for the preconcentration step were 48% for 4-methylbenzylammonium, 43% for benzylammonium, 30-32% for alkali metal ions and 71-75% for alkaline earth cations. In all cases, recoveries were reproducible with RSDs being less than 6.2%. The influences of the ion-exchange selectivity coefficient of the analyte and the sample-loading rate on analyte recovery were also examined. The proposed method was utilised for the determination of alkaline earth cations and low microM detection limits were obtained.

Benzylammonium Compounds↗

Sensitive determination of carbohydrates labelled with p-nitroaniline by capillary electrophoresis with photometric detection using a 406 nm light-emitting diode.

p-Nitroaniline was explored as a derivatising reagent for UV absorbance detection of carbohydrates after separation by CE. This derivatising agent has three advantages: first, it has excellent water solubility; second, it has high molar absorptivity; and third, it is possible to obtain sensitive detection using a UV or blue light-emitting diode (LED) as the light source. The labelling reaction took less than 30 min to complete with high reaction yield. The separation process was modelled and optimised using an artificial neural network. Nine carbohydrates were separated by a CE system within 16 min using a 0.17 M boric acid buffer at pH 9.7. On-column LED detection at 406 nm allowed the detection of carbohydrates with good detection limits (<1.1 microM or 8.8 fmol) and reproducible quantification in the concentration range of 2.6-200 microM. This method was applied successfully to the determination of component carbohydrates in some food samples.

Aniline Compounds↗

Monolithic stationary phases for fast ion chromatography and capillary electrochromatography of inorganic ions.

The focus of this review is on current developments in monolithic stationary phases for the fast analysis of inorganic ions and other small molecules in ion chromatography (IC) and capillary electrochromatography (CEC), concentrating in particular on the properties of organic (polymer) monolithic materials in comparison to inorganic (silica-based) monoliths. The applicability of these materials for fast IC is discussed in the context of recent publications, including the range of synthesis and modification procedures described. While commercial monolithic silica columns already show promising results on current IC instrumentation, polymer-based monolithic stationary phases are currently predominantly used in the capillary format on modified micro-IC systems. However, they are beginning to find application in IC particularly under high pH conditions, with the potential to replace their particle-packed counterparts.

Chromatography, Liquid↗

Towards high capacity latex-coated porous polymer monoliths as ion-exchange stationary phases.

The preparation of high capacity agglomerated monolithic ion-exchangers for capillary ion chromatography is described. Post-modification of reactive monoliths was investigated as an alternative to co-polymerisation of a suitable functional monomer with an overarching goal of increasing ion-exchange capacity. Direct sulfonation of poly styrene-co-divinyl benzene monoliths using concentrated sulfuric acid or chlorosulfonic acid was unsuccessful even for monoliths containing as low as 8% crosslinker. In contrast, chemical transformation of reactive monoliths containing glycidyl methacrylate was used to increase the ion-exchange capacity by up to more than thirty-fold with ion exchange capacities of 14-29 microequiv g(-1) achieved. Three different reactions were considered, including reaction with 4-hydroxybenenesulfonic acid under basic conditions; reaction with thiobenzoic acid followed by transformation to a reactive thiol and the subsequent oxidation to the sulfonic acid; and direct sulfonation with sodium sulfite. Of these, the reaction with sodium sulfite resulted in the most significant increase in the capacity and the best separation performance. In the isocratic mode separation efficiencies of over 13,500 plates m(-1) were observed (for iodate). The separation of seven inorganic anions was also demonstrated using a hydroxide gradient.

Chromatography, Ion Exchange↗

Preparation and characterisation of anion-exchange latex-coated silica monoliths for capillary electrochromatography.

Silica monoliths coated with functionalised latex particles have been prepared for use in monolithic ion-exchange capillary electrochromatography (IE-CEC) for the separation of inorganic anions. The ion-exchange monoliths were prepared using 70 nm quaternary ammonium, anion-exchange latex particles, which were bound electrostatically to a monolithic silica skeleton synthesised in a fused silica capillary. The resulting stationary phases were characterised in terms of their chromatographic performance and capacity. The capacity of a 50 microm diameter 25 cm latex-coated silica monolith was found to be 0.342 nanoequivalents and 80,000 theoretical plates per column were typically achieved for weakly retained anions, with lower efficiency being observed for analytes exhibiting strong ion-exchange interaction with the stationary phase. The electroosmotic flow (EOF) was reversed after the latex-coating was applied (-25.96 m2 V(-1) s(-1), relative standard deviation (RSD) 2.8%) and resulted in anions being separated in the co-EOF mode. Ion-exchange interactions between the analytes and the stationary phase were manipulated by varying the ion-exchange selectivity coefficient and the concentration of a competing ion (phosphate or perchlorate) present in the electrolyte. Large concentrations of competing ion (greater than 1M phosphate or 200 mM perchlorate) were required to completely suppress ion-exchange interactions, which highlighted the significant retention effects that could be achieved using monolithic columns compared to open tubular columns, without the problems associated with particle-packed columns. The latex-coated silica monoliths were easily produced in bulk quantities and performed reproducibly in acidic electrolytes. The high permeability and beneficial phase ratio makes these columns ideal for micro-LC and preconcentration applications.

Chromatography, Ion Exchange↗

Hydrodistillation-headspace solvent microextraction, a new method for analysis of the essential oil components of Lavandula angustifolia Mill.

A new method involving concurrent headspace solvent microextraction combined with continuous hydrodistillation (HD-HSME) for the extraction and pre-concentration of the essential oil of Lavandula angustifolia Mill. into a microdrop is developed. A microdrop of n-hexadecane containing n-heptadecane (as internal standard) extruded from the needle tip of a gas chromatographic syringe was inserted into the headspace above the plant sample. After extraction for an optimized time, the microdrop was retracted into the syringe and injected directly into a GC injection port. The effects of the type of extracting solvent, sample mass, microdrop volume and extraction time on HD-HSME efficiency were investigated and optimized. Using this method, thirty-six compounds were extracted and identified. Linalool (32.8%), linalyl acetate (17.6%), lavandulyl acetate (15.9%), alpha-terpineol (6.7%) and geranyl acetate (5.0%) were found to be the major constituents. To the best of our knowledge this is the first report on the use of continuous headspace solvent microextraction coupled with hydrodistillation for investigation of essential oil components.

Acetates↗

On-line preconcentration of organic anions in capillary electrophoresis by solid-phase extraction using latex-coated monolithic stationary phases.

Quaternary ammonium functionalised polymeric latex particles were coated onto the wall of a fused-silica capillary or onto a methacrylate monolithic bed synthesised inside the capillary in order to create ion-exchange stationary phases of varying ion-exchange capacity. These capillaries were coupled in-line to a separation capillary and used for the solid-phase extraction (SPE), preconcentration and subsequent separation of organic anions by capillary electrophoresis. A transient isotachophoretic gradient was used for the elution of bound analytes from the SPE phase using two modes of separation. The first comprised a low capacity SPE column combined with a fluoride/octanesulfonate discontinuous electrolyte system in which peak compression occurred at the isotachophoretic gradient front. The compressed anions were separated electrophoretically after elution from the SPE preconcentration phase and resolution was achieved by altering the pH of the electrolyte in which the separation was performed. In the second approach, a latex-coated monolithic SPE preconcentration stationary phase was used in combination with a fluoride/perchlorate electrolyte system, which allowed capillary electrochromatographic separation to occur behind the isotachophoretic gradient front. This method permitted the removal of weakly bound anions from the SPE phase, thereby establishing the possibility of sample clean-up. The effect of the nature of the strong electrolyte forming the isotachophoretic gradient on the separation and also on the preconcentration step was investigated. Capillary electrochromatography of inorganic and organic species performed on the latex-coated monolithic methacrylate column highlighted the presence of mixed-mode interactions resulting from the incomplete coverage of latex particles onto the monolithic surface. Analyte preconcentration prior to separation resulted in compression of the analyte zone by a factor of 300. Improvement in the limit of detection of up to 10400 times could be achieved when performing the preconcentration step and the presented methods had limits of detection (S/N=3) ranging between 1.5 and 12 nM for the organic anions studied.

Anions↗

Stabilization of sulfide and sulfite and ion-pair chromatography of mixtures of sulfide, sulfite, sulfate and thiosulfate.

Ion chromatography of sulfide, sulfite, sulfate and thiosulfate in a mixture is often difficult because of instability of sulfide and sulfite, poor separation of sulfide from common anions such as bromide or nitrate and similar elution-times for sulfite and sulfate. An ion-pair chromatographic method for the determination of these sulfur anions has been established by stoichiometric conversion of sulfide and sulfite into stable thiocyanate and sulfate, respectively, prior to the chromatographic run. Sulfate, thiosulfate and thiocyanate were resolved on an octadecylsilica column with an acetonitrile-water mobile phase containing tetrapropylammonium salt (TPA) as an ion-paring reagent, and thiosulfate and thiocyanate in the effluent could be measured with a photometric detector (220 nm) and sulfate with a suppressed conductivity detector. When an acetonitrile-water (6:94, v/v) mobile phase (pH 5.0) containing 15 mM TPA and small amounts of acetic acid was used at a flow-rate of 0.6 ml min(-1), the three anions could be eluted within 32 min. Calibration plots of peak height versus concentration for sulfide (detected as thiocyanate) and thiosulfate gave straight lines up to 35 and 60 microM, respectively. The calibration plot for sulfide coincided with that obtained by using thiocyanate. A calibration plot for sulfite, measured as sulfate, was also linear up to 135 microM and was in accord with that of sulfate. Each calibration plot gave a correlation coefficient greater than 0.999. For six replicates obtained for a mixture of 30.0 microM sulfide, 50.0 microM sulfite, 50.0 microM sulfate and 20.0 microM thiosulfate, the proposed method gave a mean value of 30.1 microM with a standard deviation (SD) of 0.77 microM and a relative standard deviation (RSD) of 2.6% for sulfide, 101 microM (SD = 3.5 microM, RSD = 3.5%) for the total of sulfite and sulfate and 20.1 microM (SD = 0.44 microM, RSD = 2.2%) for thiosulfate. Recoveries for sulfide, sulfite plus sulfate, and thiosulfate in hot-spring water samples using the proposed method were found to be quantitative.

Anions↗

Contactless conductivity detection of synthetic polymers in non-aqueous size-exclusion electrokinetic chromatography.

A capacitively coupled contactless conductivity detection (CCD) system has been applied for the detection of neutral synthetic polymers in capillary size-exclusion electrokinetic chromatography (SEEC). Polystyrene standards, that were used as a model compounds, were separated on a capillary column packed with porous 10 microm silica particles with an electrokinetically driven mobile phase, and detected by CCD and UV detection simultaneously. Mass-calibration curves for polystyrene were constructed. Satisfactory results were obtained for the linearity, the run-to-run repeatability (<0.2% for the relative retention and <4% for the peak area) and the robustness of the detector. One of the major issues in this preliminary study was to investigate the origin of the peaks observed for the polystyrene standards. The effect of the molar mass of the polystyrenes on the sensitivity was small. Therefore, the signals obtained could not be explained as the result of an increased viscosity and a decreased solution conductivity of the solute zone. An alternative hypothesis is suggested, and recommendations for further research are given.

Calibration↗

Latex-coated polymeric monolithic ion-exchange stationary phases. 2. Micro-ion chromatography.

Latex-coated monolithic polymeric stationary phases are used for micro-ion chromatography (mu-IC) of inorganic anions. Monolithic columns were prepared by the in situ polymerization of butyl methacrylate, ethylene dimethacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid within fused-silica capillaries of varying internal diameters. Introduction of ion-exchange sites was achieved by coating the anionic polymeric monolith with either Dionex AS10 or Dionex AS18 quaternary ammonium functionalized latex particles to give total ion-exchange capacities in the range 9-24 nequiv for a 30-cm column. The resultant mu-IC columns were used for the separation of anionic analytes using chloride or acetate as the eluent-competing ion and direct UV spectrophotometric detection at 195 nm or using hydroxide as the eluent-competing ion and suppressed or nonsuppressed contactless conductivity detection. Separation efficiencies of 13,000 plates/m were observed (for iodate), and separation efficiency was maintained for large increases in flow rate (up to 42 microL/min, corresponding to a linear flow velocity of 18.5 mm/s), enabling highly reproducible, rapid separations to be achieved (seven analyte anions in less than 2 min). Use of a hollow fiber micromembrane suppressor enabled effective suppression of hydroxide eluents over the range 0.5-5.0 mM, thereby permitting suppressed conductivity detection to be performed. However, the relatively large size of the suppressor resulted in reduced separation efficiencies (e.g., 5400 plates/m for iodate). Detection limits obtained with suppressed conductivity detection were in the range 0.4-1.2 microM.

Journal Article↗

Latex-coated polymeric monolithic ion-exchange stationary phases. 1. Anion-exchange capillary electrochromatography and in-line sample preconcentration in capillary electrophoresis.

A sulfonated methacrylate monolithic polymer has been synthesized inside fused-silica capillaries of diameters 50-533-microm i.d. and coated with 65-nm-diameter fully functionalized quaternary ammonium latex particles (AS18, Dionex Corp.) to form an anion-exchange stationary phase. This stationary phase was used for ion-exchange capillary electrochromatography of inorganic anions in a 75-microm-i.d. capillary with Tris/perchlorate electrolyte and direct UV detection at 195 nm. Seven inorganic anions (bromide, nitrate, iodide, iodate, bromate, thiocyanate, chromate) could be separated over a period of 90 s, and the elution order indicated that both ion exchange and electrophoresis contributed to the separation mechanism. Separation efficiencies of up to 1.66 x 10(5) plates m(-1) were achieved, and the monoliths were stable under pressures of up to 62 MPa. Another latex-coated monolith in a 250-microm-i.d. capillary was used for in-line preconcentration by coupling it to a separation capillary in which the EOF had been reversed using a coating of either a cationic polymer or cationic latex particles. Several capillary volumes of sample were loaded onto the preconcentration monolith, and the analytes (inorganic anions) were then eluted from the monolith with a transient isotachophoretic gradient before being separated by electrophoresis in the separation capillary. Linear calibration curves were obtained for aqueous mixtures of bromide, nitrite, nitrate, and iodide. Recoveries of all analytes except iodide were reduced significantly when the sample matrix contained high levels of chloride. The preconcentration method was applied to the determination of iodide in open ocean water and provided a limit of detection of 75 pM (9.5 ng/L) calculated at a signal-to-noise ratio of 3. The relative standard deviation for migration time and peak area for iodide were 1.1 and 2.7%, respectively (n = 6). Iodide was eluted as an efficient peak, yielding a separation efficiency of 5.13 x 10(7) plates m(-1). This focusing was reproducible for repeated analyses of seawater.

Journal Article↗

Isoelectric buffers for capillary electrophoresis. 2. Bismorpholine derivative of a carboxylic acid as a low molecular weight isoelectric buffer.

A new compound class of synthetic isoelectric buffers is introduced, designed as a small molecule with one fully or prevailingly dissociated acidic group (such as sulfonic or carboxylic) and two partly pronated (buffering) basic amino groups attached onto a hydrophilic UV-transparent backbone. As an example, a new isoelectric compound 2,2-bis(4-morpholinylmethyl)propanoic acid (BMMPA) was synthesized by attaching two morpholine groups onto a molecule of pivalic acid. It was characterized as having an isoelectric point pI = 6.5 and exhibiting satisfactory buffering capacity at the pI. Solutions of BMMPA are transparent down to the low-UV spectral region, thus making it a potentially suitable buffer for a number of separation methods. Its use in capillary electrophoresis was demonstrated in a separation system for indirect photometric detection of anions based on an electrolyte with the anionic dye Orange G as the indirect detection probe and using BMMPA as a buffer. The use of an isoelectric buffering compound brings the advantages of a buffered electrolyte without the concomitant introduction of co-ions that would be detrimental to the indirect detection process. Submicromole per liter limits of detection for a number of inorganic and small organic ions were achieved. Optimal structural properties of the isoelectric buffer with respect to its buffering properties are discussed.

Journal Article↗

Internal electrolyte temperatures for polymer and fused-silica capillaries used in capillary electrophoresis.

Polymers are important as materials for manufacturing microfluidic devices for electrodriven separations, in which Joule heating is an unavoidable phenomenon. Heating effects were investigated in polymer capillaries using a CE setup. This study is the first step toward the longer-term objective of the study of heating effects occurring in polymeric microfluidic devices. The thermal conductivity of polymers is much smaller than that of fused silica (FS), resulting in less efficient dissipation of heat in polymeric capillaries. This study used conductance measurements as a temperature probe to determine the mean electrolyte temperatures in CE capillaries of different materials. Values for mean electrolyte temperatures in capillaries made of New Generation FluoroPolymer (NGFP), poly-(methylmethacrylate) (PMMA), and poly(ether ether ketone) (PEEK) capillaries were compared with those obtained for FS capillaries. Extrapolation of plots of conductance versus power per unit length (P/L) to zero power was used to obtain conductance values free of Joule heating effects. The ratio of the measured conductance values at different power levels to the conductance at zero power was used to determine the mean temperature of the electrolyte. For each type of capillary material, it was found that the average increase in the mean temperature of the electrolyte (DeltaT(Mean)) was directly proportional to P/L and inversely proportional to the thermal conductivity (lambda) of the capillary material. At 7.5 W/m, values for DeltaT(Mean) for NGFP, PMMA, and PEEK were determined to be 36.6, 33.8, and 30.7 degrees C, respectively. Under identical conditions, DeltaT(Mean) for FS capillaries was 20.4 degrees C.

Benzophenones↗

Simultaneous separation of anions and cations by capillary electrophoresis with high magnitude, reversed electroosmotic flow.

A method for simultaneous separation and indirect detection of anions and cations by capillary electrophoresis (CE) is reported. An anodic electroosmotic flow (EOF) in excess of -100 x 10(-9) m2 V(-1) s(-1) was achieved by the addition of 0.1 mM didodecyldimethylammonium bromide (DDAB) to the background electrolyte (BGE). This high magnitude EOF enabled rapid co-EOF separation of inorganic anions and counter-EOF separation of inorganic cations having high electrophoretic mobilities. Single-end injection of the sample at the capillary inlet and detection near the capillary outlet was used. Indirect photometric detection of cations was accomplished using a cationic probe (imidazole), with counter-ionic (Kohlrausch) indirect detection being used for anions. A mixture consisting of chloride, bromide, nitrate, lithium, magnesium, sodium, calcium, potassium, and ammonium was separated in less than 3.5 min using a background electrolyte comprising 6 mM imidazole, 12 mM hydroxyisobutyric acid, 0.1 mM DDAB, 2 mM 18-crown-6 at pH 4.0, with indirect detection at 210 nm. The system was well suited to the separation and detection of inorganic cations, with limits of detection (LODs) in the range 0.92-4.65 microM and separation efficiencies from 44,400-208,5000 theoretical plates. By contrast, LODs for inorganic anions ranged from 6.66 to 11.43 microM, with separation efficiencies of 2500-26,300. Analytical potential of the method is discussed.

Anions↗