PubMed Health⌕ Search

Biomedical subjects

Peggy Palanchon

Publications and source records attributed to Peggy Palanchon.

2 recordsLinked to original sources

Multifrequency transducer for microemboli classification and sizing.

The classification of circulating microemboli as gaseous or particulate matter is essential to establish the relevance of the detected embolic signals. Until now, Doppler techniques have failed to determine unambiguously the nature of circulating microemboli. Recently, a new approach based on the analysis of radio frequency (RF) signal and using the nonlinear characteristics of gaseous bubbles to classify emboli was investigated. The main limitation of these studies was the requirement of two separate transducers for transmission and reception. This paper presents a multi-frequency transducer with two independent transmitting elements and a separate receiving part with a wide frequency band. The transmitting elements are positioned in a concentric design and cover a frequency band between 100 and 600 kHz. The receiving part consists of a polyvinylidene fluoride layer. The new transducer has been tested in vitro using gaseous emboli. It could correctly classify and size air emboli with diameters ranging from 10 microm to 105 microm.

Electromagnetic Phenomena↗

Optical observations of acoustical radiation force effects on individual air bubbles.

Previous studies dealing with contrast agent microbubbles have demonstrated that ultrasound (US) can significantly influence the movement of microbubbles. In this paper, we investigated the influence of the acoustic radiation force on individual air bubbles using high-speed photography. We emphasize the effects of the US parameters (pulse length, acoustic pressure) on different bubble patterns and their consequences on the translational motion of the bubbles. A stream of uniform air bubbles with diameter ranging from 35 microm to 79 microm was generated and insonified with a single US pulse emitted at a frequency of 130 kHz. The bubble sizes have been chosen to be above, below, and at resonance. The peak acoustic pressures used in these experiments ranged from 40 kPa to 120 kPa. The axial displacements of the bubbles produced by the action of the US pulse were optically recorded using a high-speed camera at 1 kHz frame rate. The experimental results were compared to a simplified force balance theoretical model, including the action of the primary radiation force and the fluid drag force. Although the model is quite simple and does not take into account phenomena like bubble shape oscillations and added mass, the experimental findings agree with the predictions. The measured axial displacement increases quasilinearly with the burst length and the transmitted acoustic pressure. The axial displacement varies with the size and the density of the air bubbles, reaching a maximum at the resonance size of 48 microm. The predicted displacement values differ by 15% from the measured data, except for resonant bubbles for which the displacement was overestimated by about 40%. This study demonstrates that even a single US pulse produces radiation forces that are strong enough to affect the bubble position.

Acoustics↗