PubMed Health⌕ Search

Biomedical subjects

Pekka E Hänninen

Publications and source records attributed to Pekka E Hänninen.

6 recordsLinked to original sources

Effect of polystyrene microsphere surface to fluorescence lifetime under two-photon excitation.

Molecular assays such as immunoassays are often performed using solid carriers and fluorescent labels. In such an assay format a question can be raised on how much the fluorescence of the label is influenced by the bio-affinity binding events and the solid carrier surface. Since changes in fluorescence intensity as labels bind to surfaces are notoriously difficult to quantify other approaches are preferred. A good indicator, independent of the fluorescence intensity of the label, is the fluorescence lifetime of the marker fluorophore. Changes in fluorescence lifetime reliably indicate the presence of dynamic quenching, energy transfer or other de-excitation processes. A microsphere based assay system is studied under two-photon excitation. Changes in fluorescence lifetime are studied as labeled protein conjugates bind on microsphere surfaces--both direct on the surface and with a few nanometer distance from the surface. Fluorescence signal is measured from individual polystyrene microspheres and the fluorescence lifetime histogram is simultaneously recorded. The results indicate that self-quenching and quenching by the polystyrene surface are both present in such a system. However, the effect of the surface can be avoided by increasing the distance between the surface and the label. Typical distances achieved by a standard sandwich type of assay, are already sufficient to overcome the surface induced quenching in fluorescence detection.

Animals↗

Two-photon excitation in fluorescence polarization receptor-ligand binding assay.

Fluorescence polarization is one of the most commonly used homogeneous assay principles in drug discovery for screening of potential lead compounds. In this article, the fluorescence polarization technique is combined with 2-photon excitation of fluorescence. Theoretically, the use of 2-photon excitation of fluorescence increases the volumetric sensitivity and polarization contrast of fluorescence polarization assays. The work in this report demonstrates these predictions for an estrogen receptor ligand binding assay.

Fluorescence Polarization↗

Fluorescent nanoparticles as labels for immunometric assay of C-reactive protein using two-photon excitation assay technology.

We describe the use of fluorophore-doped nanoparticles as reporters in a recently developed ArcDia TPX bioaffinity assay technique. The ArcDia TPX technique is based on the use of polymer microspheres as solid-phase reaction carrier, fluorescent bioaffinity reagents, and detection of two-photon excited fluorescence. This new assay technique enables multiplexed, separation-free bioaffinity assays from microvolumes with high sensitivity. As a model analyte we chose C-reactive protein (CRP). The assay of CRP was optimized for assessment of CRP baseline levels using a nanoparticulate fluorescent reporter, 75 nm in diameter, and the assay performance was compared to that of CRP assay based on a molecular reporter of the same fluorophore core. The results show that using fluorescent nanoparticles as the reporter provides two orders of magnitude better sensitivity (87 fM) than using the molecular label, while no difference between precision profiles of the different assay types was found. The new assay method was applied for assessment of baseline levels of CRP in sera of apparently healthy individuals.

Antibodies, Monoclonal↗

Detection methods of microsphere based single-step bioaffinity and in vitro diagnostics assays.

Microspheres provide a solid phase substrate for bioaffinity binding similar to the walls of traditional test tubes and the wells of microtiter plates. The coated microsphere concentrates analyte molecules in the reaction volume on its surface. When the bioaffinity binding reaction has reached an equilibrium, the local concentration of the analyte in close proximity of the microsphere is orders of magnitude higher than the concentration of the analyte in the total reaction volume. The preparation and quality control of microspheres coated with bioactive material is less costly and labour intensive when compared to test tube or microwell plate coating procedures. In addition, the cost for logistics and transportation of microsphere reagents is lower than that of coated tubes or plates. Moreover, microspheres can be easily used in miniaturised assay formats and several different detection schemes can be employed in the measurement of microsphere-based assays. Several different types of microspheres are commercially available. The microspheres can be manufactured in different sizes from many materials, such as polystyrene, acrylate, and glass. The surface of the microspheres can be activated to enable covalent binding of biomolecules. Further, the microspheres may contain internal fluorochrome or magnetic material, for identification or separation purposes. In this paper we review different assay formats for single-step measurement of bioaffinity assays employing microspheres. The term single-step is used to describe assays where all reagents and the sample are mixed, incubated and measured without separate washing steps.

Antibodies↗

Syntheses of novel dipyrrylmethene-BF2 dyes and their performance as labels in two-photon excited fluoroimmunoassay.

Two-photon excitation of fluorescence (TPE) has been found a powerful tool in the field of microscopy imaging and recently also in the field of bioanalytics. The recently introduced bioaffinity assay technology, ArcDia TPX, enables separation-free ultra-sensitive immunoassays from microvolumes. This assay technique is based on the use of microspheres as a solid reaction carriers and two-photon excited fluorescence detection. In the ArcDia TPX-technology, the individual microparticles are observed and the number of bound biomolecules on the microparticle surface is quantified by two-photon excited fluorescence. Here we present synthesis and use of a novel dipyrrylmethene-BF2 fluorophore that has been designed to be used as label in ArcDia TPX assay technique. The absorption and emission wavelengths of the label are tuned to allow excitation with a 1064 nm microchip laser. The label contains two-carboxylic residues, one of which is activated as N-hydroxysuccinimide ester to enable labeling of amino residues of biomolecules. The other carboxylic group is in free form to increase solubility in aqueous solutions. This new fluorescent label is tested in a separation-free immunoassay using ArcDia TPX assay technique. The performance of the new label is compared to that of one of the brightest fluorophores available, R-phycoerythrin (RPE). According to the results, the dipyrrylmethene-BF2 label provides significantly better signal-to-background ratio, leading to higher assay sensitivity and broader dynamic range compared to that of RPE. Good solubility to aqueous solutions and high fluorescence quantum efficiency, suggests the dipyrrylmethene-BF2 label is applicable also in other fluorescence-based applications.

Animals↗

Two-photon excitation fluorometric measurement of homogeneous microparticle immunoassay for C-reactive protein.

Recent developments in infrared laser technology have enabled the design of a compact instrumentation for two-photon excitation microparticle fluorometry (TPX). The microparticles can be used in immunoassays as the antibody-coated solid phase to capture an antigen and then detect it with a fluorescently labeled tracer antibody. Unlike most other methods, TPX technology allows low-volume, homogeneous immunoassays with real-time measurements of assay particles in the presence of a moderate excess of fluorescent tracer. In this study, the TPX assay system was used for the reagent characterization and the measurement of C-reactive protein (CRP) in diluted plasma samples, targeting the assay range useful in infectious disease diagnosis. The pentameric structure of the CRP permitted the optimization of an assay with the lowest detectable concentration of 1 microg/L (7.5 pM) by using a single monoclonal antibody both for capture and as the tracer. With a 1:200 predilution of samples, the measurement range of the assay was 1-150 mg/L, but an additional 1:10 dilution was required for higher concentrations. The TPX method showed a good correlation with the reference result obtained in a routine hospital laboratory, demonstrating the feasibility of the technology for immunodiagnostic applications.

Antibodies, Monoclonal↗