Gas chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.

An atmospheric pressure chemical ionization (APCI) microchip is presented for combining a gas chromatograph (GC) to a mass spectrometer (MS). The chip includes capillary insertion channel, stopper, vaporizer channel, nozzle and nebulizer gas inlet fabricated on the silicon wafer, and a platinum heater sputtered on a glass wafer. These two wafers are joined by anodic bonding creating a two-dimensional version of an APCI microchip. The sample from GC is directed via heated transfer line capillary to the vaporizer channel of the APCI chip. The etched nozzle forms narrow sample plume, which is ionized by an external corona discharge needle, and the ions are analyzed by a mass spectrometer. The GC-microchip APCI-MS combination provides an efficient method for qualitative and quantitative analysis. The spectra produced by microchip APCI show intensive protonated molecule and some fragmentation products as in classical chemical ionization for structure elucidation. In quantitative analysis the GC-microchip APCI-MS showed good linearity (r(2) = 0.9989) and repeatability (relative standard deviation 4.4%). The limits of detection with signal-to-noise ratio of three were between 0.5 and 2 micromol/L with MS mode using selected ion monitoring and 0.05 micromol/L with MS/MS using multiple reaction monitoring.

Anisoles↗

Capillary liquid chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.

A miniaturized nebulizer chip for capillary liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (capillary LC-microchip APCI-MS) is presented. The APCI chip consists of two wafers, a silicon wafer and a Pyrex glass wafer. The silicon wafer has a DRIE etched through-wafer nebulizer gas inlet, an edge capillary insertion channel, a stopper, a vaporizer channel and a nozzle. The platinum heater electrode and pads for electrical connection were patterned on to the Pyrex glass wafer. The two wafers were joined by anodic bonding, creating a microchip version of an APCI-source. The sample inlet capillary from an LC column is directly connected to the vaporizer channel of the APCI chip. The etched nozzle in the microchip forms a narrow sample plume, which is ionized by an external corona needle, and the formed ions are analyzed by a mass spectrometer. The nebulizer chip enables for the first time the use of low flow rate separation techniques with APCI-MS. The performance of capillary LC-microchip APCI-MS was tested with selected neurosteroids. The capillary LC-microchip APCI-MS provides quantitative repeatability and good linearity. The limits of detection (LOD) with a signal-to-noise ratio (S/N) of 3 in MS/MS mode for the selected neurosteroids were 20-1000 fmol (10-500 nmol l(-1)). LODs (S/N = 3) with commercial macro APCI with the same compounds using the same MS were about 10 times higher. Fast heat transfer allows the use of the optimized temperature for each compound during an LC run. The microchip APCI-source provides a convenient and easy method to combine capillary LC to any API-MS equipped with an APCI source. The advantages and potentials of the microchip APCI also make it a very attractive interface in microfluidic APCI-MS.

Atmospheric Pressure↗

Minimum proton affinity for efficient ionization with atmospheric pressure desorption/ionization on silicon mass spectrometry.

We performed a systematic study using a set of compounds with different proton affinities (PAs) on the ionization in atmospheric pressure desorption/ionization on silicon mass spectrometry (AP-DIOS-MS). The compounds studied included various aromatic molecules of different sizes. The PAs of these compounds were calculated using ab initio and hybrid density functional theory calculations at the B3LYP/6-31G(d) level of theory. We observed that only compounds with relatively high PAs above a threshold value of 920-950 kJ/mol were efficiently ionized as protonated molecules under AP-DIOS conditions and produced very clean mass spectra.

Adsorption↗

Atmospheric pressure photoionization-mass spectrometry with a microchip heated nebulizer.

A novel, microfabricated heated nebulizer chip for atmospheric pressure photoionization-mass spectrometry (APPI-MS) is presented. The chip consists of fluidic and gas inlets, a mixer, and a nozzle etched onto silicon wafer that is anodically bonded to a Pyrex glass wafer, on which an aluminum heater is sputtered. A krypton discharge lamp is used as the source for 10-eV photons to initiate the photoionization process. Dopant, delivered as part of the sample solution, is used to achieve efficient ionization. The use of the microfabricated heated nebulizer with APPI in the analysis of four analytes is demonstrated, and the spectra are compared to those obtained with a conventional APPI source. Ionization in positive and negative ion modes was successfully achieved and the spectra were mainly similar to those obtained with conventional APPI, indicating that the ionization in microfabricated and conventional APPI sources takes place by the same mechanisms. The flow rates with conventional APPI are approximately 100 muL/min, whereas the microchip heated nebulizer allows the use of flow rates 0.05-5 muL/min, thus being compatible with microfluidic separation systems or micro- and nano-LC. A stable signal was demonstrated throughout a 5-h measurement, which proved the excellent stability of the micro-APPI. The same heated nebulizer chip can be used for weeks.

Atmospheric Pressure↗

Microchip atmospheric pressure chemical ionization source for mass spectrometry.

A novel microchip heated nebulizer for atmospheric pressure chemical ionization mass spectrometry is presented. Anisotropic wet etching is used to fabricate the flow channels, inlet, and nozzle on a silicon wafer. An integrated heater of aluminum is sputtered on a glass wafer. The two wafers are jointed by anodic bonding, creating a two-dimensional version of an APCI source with a sample channel in the middle and gas channels symmetrically on both sides. The ionization is initiated with an external corona-discharge needle positioned 2 mm in front of the microchip heated nebulizer. The microchip APCI source provides flow rates down to 50 nL/min, stable long-term analysis with chip lifetime of weeks, good quantitative repeatability (RSD < 10%) and linearity (r(2) > 0.995) with linear dynamic rage of at least 4 orders of magnitude, and cost-efficient manufacturing. The limit of detection (LOD) for acridine measured with microchip APCI at flow rate of 6.2 muL/min was 5 nM, corresponding to a mass flow of 0.52 fmol/s. The LOD with commercial macro-APCI at a flow rate of 1 mL/min for acridine was the same, 5 nM, corresponding to a significantly worse mass flow sensitivity (83 fmol/s) than measured with microchip APCI. The advantages of microchip APCI makes it a very attractive new microfluidic detector.

Atmospheric Pressure↗