PubMed Health⌕ Search

Biomedical subjects

Penyuan Yang

Publications and source records attributed to Penyuan Yang.

2 recordsLinked to original sources

Poly(methyl methacrylate) CE microchips replicated from poly(dimethylsiloxane) templates for the determination of cations.

A novel method for the rapid fabrication of poly(methyl methacrylate) (PMMA) microfluidic chips using poly(dimethylsiloxane) (PDMS) templates has been demonstrated. The PDMS molds were fabricated by soft lithography. The dense prepolymerized solution of methyl methacrylate containing thermal and UV initiators was allowed to polymerized between a PDMS template and a piece of a 1 mm thick commercial PMMA plate under a UV lamp. The images of microchannels on the PDMS template were precisely replicated into the synthesized PMMA substrates during the UV-initiated polymerization of the prepolymerized solution on the surface of the PMMA plate at room temperature. The polymerization could be completed within 10 min under ambient temperature. The chips were subsequently assembled by thermal bonding of the channel plate and the cover sheet. The new fabrication method obviates the need for specialized replication equipment and reduces the complexity of prototyping and manufacturing. Nearly 20 PMMA chips were replicated using a single PDMS mold. The attractive performance of the new microfluidic chips has been demonstrated by separating and detecting cations in connection with contactless conductivity detection. The fabricated PMMA microchip has also been successfully employed for the determination of potassium and sodium in environmental and biological samples.

Cations, Monovalent↗

Low temperature bonding of poly(methylmethacrylate) electrophoresis microchips by in situ polymerisation.

A novel method for bonding poly(methyl methacrylate) (PMMA) electrophoresis microchips at the temperature below the glass transition temperature of PMMA based on in situ polymerization has been demonstrated. Methyl methacrylate (MMA) containing initiators was allowed to prepolymerize in an 85 degrees C water bath for 8 min and 15 min to produce a bonding solution and a dense molding solution, respectively. The channel plate of the PMMA microchip was fabricated by the UV-initiated polymerization of the molding solution between a nickel template and a PMMA plate at room temperature. Prior to bonding, the blank cover was coated with a thin layer of the bonding solution and was bonded to the channel plate at 95 degrees C for 20 min under the pressure of binder clips. The attractive performance of the PMMA chips bonded by the new approach has been demonstrated by separating and detecting dopamine, catechol, three cations, and three organic acids in connection with end-column amperometric detection and contactless conductivity detection.

Cold Temperature↗