Feature extraction for systolic heart murmur classification.

Heart murmurs are often the first signs of pathological changes of the heart valves, and they are usually found during auscultation in the primary health care. Distinguishing a pathological murmur from a physiological murmur is however difficult, why an "intelligent stethoscope" with decision support abilities would be of great value. Phonocardiographic signals were acquired from 36 patients with aortic valve stenosis, mitral insufficiency or physiological murmurs, and the data were analyzed with the aim to find a suitable feature subset for automatic classification of heart murmurs. Techniques such as Shannon energy, wavelets, fractal dimensions and recurrence quantification analysis were used to extract 207 features. 157 of these features have not previously been used in heart murmur classification. A multi-domain subset consisting of 14, both old and new, features was derived using Pudil's sequential floating forward selection (SFFS) method. This subset was compared with several single domain feature sets. Using neural network classification, the selected multi-domain subset gave the best results; 86% correct classifications compared to 68% for the first runner-up. In conclusion, the derived feature set was superior to the comparative sets, and seems rather robust to noisy data.

Aged↗

Effects of ultrasound contrast agents on Doppler tissue velocity estimation.

The combination of Doppler tissue imaging and myocardial contrast echocardiography has the potential to provide information about motion and perfusion of the myocardium in a single examination. The purpose of this study was to establish how the presence of ultrasound contrast agent (UCA) affects measurements of Doppler tissue velocities in vivo and in vitro. We performed echocardiography in 12 patients with ischemic heart disease before and immediately after a slow intravenous infusion of the UCA Optison, using color Doppler tissue imaging to examine the effect of contrast agents in vivo. The myocardial peak systolic velocities and their integrals were analyzed in digitally stored cineloops before and after contrast administration. To distinguish between methodologic and physiologic factors affecting the measurement of tissue velocity in vitro, experiments with a rotating disk and a flow cone phantom were also carried out for the 3 contrast agents: Optison, Sonovue, and Sonazoid. In vivo results show that the values for peak systolic velocity increased by about 10% during contrast infusion, from mean 5.2 +/- 1.8 to 5.7 +/- 2.3 cm/s (P = .02, 95% confidence interval 2%-16%). The increase in myocardial peak systolic velocities was verified in experimental models in which the UCA increased the estimated mean velocity in the order of 5% to 20% for the motion interval of 5 to 7 cm/s, corresponding to the myocardial velocities studied in vivo. The response was similar for all 3 contrast agents and was not affected by moderate variations in concentration of the agent. We have shown that the presence UCA will affect Doppler tissue measurements in vivo and in vitro. The observed bias is presumed to be an effect of harmonic signal contribution from rupturing contrast agent microbubbles and does not indicate biologic or physiologic effects.

Aged↗

Noninvasive investigation of blood pressure changes using the pulse wave transit time: a novel approach in the monitoring of hemodialysis patients.

Severe blood pressure changes are well known in hemodialysis. Detection and prediction of these are important for the well-being of the patient and for optimizing treatment. New noninvasive methods for this purpose are required. The pulse wave transit time technique is an indirect estimation of blood pressure, and our intention is to investigate whether this technique is applicable for hemodialysis treatment. A measurement setup utilizing lower body negative pressure and isometric contraction was used to simulate dialysis-related blood pressure changes in normal test subjects. Systolic blood pressure levels were compared to different pulse wave transit times, including and excluding the cardiac preejection period. Based on the results of these investigations, a pulse wave transit time technique adapted for dialysis treatment was developed and tried out on patients. To determine systolic blood pressure in the normal group, the total pulse wave transit time was found most suitable (including the cardiac preejection period). Correlation coefficients were r = 0.80 +/- 0.06 (mean +/- SD) overall and r = 0.81 +/- 0.16 and r = 0.09 +/- 0.62 for the hypotension and hypertension phases, respectively. When applying the adapted technique in dialysis patients, large blood pressure variations could easily be detected when present. Pulse wave transit time is correlated to systolic blood pressure within the acceptable range for a trend-indicating system. The method's applicability for dialysis treatment requires further studies. The results indicate that large sudden pressure drops, like those seen in sudden hypovolemia, can be detected.

Adult↗

Modelling of nonlinear effects and the response of ultrasound contrast micro bubbles: simulation and experiment.

The propagation of diagnostic ultrasonic imaging pulses in tissue and their interaction with contrast micro bubbles is a very complex physical process, which we assumed to be separable into three stages: pulse propagation in tissue, the interaction of the pulse with the contrast bubble, and the propagation of the scattered echo. The model driven approach is used to gain better knowledge of the complex processes involved. A simplified way of field simulation is chosen due to the complexity of the task and the necessity to estimate comparative contributions of each component of the process. Simulations are targeted at myocardial perfusion estimation. A modified method for spatial superposition of attenuated waves enables simulations of low intensity pulse pressure fields from weakly focused transducers in a nonlinear, attenuating, and liquid-like biological medium. These assumptions enable the use of quasi-linear calculations of the acoustic field. The simulations of acoustic bubble response are carried out with the Rayleigh-Plesset equation with the addition of radiation damping. Theoretical simulations with synthesised and experimentally sampled pulses show that the interaction of the excitation pulses with the contrast bubbles is the main cause of nonlinear scattering, and a 2-3 dB increase of second harmonic amplitude depends on nonlinear distortions of the incident pulse.

Contrast Media↗

Accuracy of spectral Doppler flow and tissue velocity measurements in ultrasound systems.

Blood and tissue velocity are measured and analysed in cardiac, vascular and other applications of diagnostic ultrasound (US). An error in system calibration is a potential risk for misinterpretation of the measurements. To determine the accuracy in velocity calibration, we tested three common commercial US systems using a Doppler string phantom. We tested pulsed and continuous-wave Doppler modes for velocities relevant to both cardiac blood flow and tissue-velocity estimation. The US systems were tested with settings and transducers commonly used in cardiac applications. One system consistently overestimated velocity by about 5%, whereas the other two systems were quite accurate in velocity estimation. These findings emphasize the importance of continuous quality control of US equipment.

Blood Flow Velocity↗

Net pressure gradients in aortic prosthetic valves can be estimated by Doppler.

BACKGROUND: In aortic prosthetic valves, both the Doppler-estimated gradients and orifice areas are misleading in the assessment of hemodynamic performance. The parameter of major interest is the net pressure gradient after pressure recovery (PR). We, therefore, investigated, in vitro, our ability to predict the net pressure gradient and applied the formulas in a representative patient population with 2 different valve designs. METHODS: We studied the St Jude Medical (SJM) standard valve (size 19-27) and SJM Biocor (size 21-27) in an in vitro steady-flow model with simultaneous Doppler-estimated pressure and catheter pressure measurements. Using echocardiography, we also studied patients who received the SJM (n = 66) and SJM Biocor (n = 45). RESULTS: In the SJM, we observed PR both within the prosthesis and aorta, whereas in the SJM Biocor, PR was only present in the aorta. We estimated the PR within the valve and within the aorta separately from echocardiographic in vitro data, combining a regression equation (valve) with an equation on the basis of fluid mechanics theory (aorta). The difference between estimated and catheter-obtained net gradients (mean +/- SD) was 0.6 +/- 1.6 mm Hg in the SJM and -0.2 +/- 1.9 mm Hg in the SJM Biocor. When these equations were applied in vivo, we found that PR had an overall value of 57 +/- 7% of the peak Doppler gradient in the SJM and 33 +/- 9% in the SJM Biocor. CONCLUSIONS: The in vitro results indicate that it is possible to predict the net pressure gradient by Doppler in bileaflet and stented biologic valves. Our data indicate that important PR is also present in stented biologic valves.

Adult↗

Cross-sectional changes in an asymmetric tube with bearing on non-invasive pressure measurements.

This study aims at investigating the radial dimensional changes, as a result of an applied intraluminal pressure for an elastic tube with non-uniform cross section. The study is related to a method for non-invasive pressure measurement using the extracorporeal tube as part of the sensor. The intended application is for monitoring of pressure in the blood and dialysate tubes during haemodialysis. The intention is to find a tube cross-section geometry that results in an expansion of the tube so that it is suitable to use as a component in a pressure sensor. The tube should have high radial compliance and expand in a well-defined manner to be able to transfer the intraluminal pressure to a transducer element sensing the radial force. Radial expansion was studied experimentally for tubes with different cross-section geometries. For small tube expansions the resolution in the experimental measurements was not sufficient to study the radial expansion. In this case, numerical simulation was performed. We conclude that a tube with essentially elliptic outer surface and circular inner surface, with a relation of 1:2 between the size of the thin and thick wall, results in a radial expansion upon application of pressure indicating that this tube is suitable for use as part of a sensor.

Elasticity↗

Time delays in ultrasound systems can result in fallacious measurements.

Even short time delays (less than 30 ms) in cardiac motion pattern may have clinical relevance. These delays can be measured with echocardiography, using techniques such as flow and tissue Doppler and M-mode together with external signals (e.g., ECG and phonocardiography). If one or more of these signals are delayed in relation to the other signals (asynchronous), an incorrect definition of cardiac time intervals can occur, the consequence of which is invalid measurement. To determine if this time delay in signal processing is a problem, we tested three common ultrasound (US) systems using the ECG as the reference signal. We used a digital ECG simulator and a Doppler string phantom to obtain test signals for flow and tissue pulsed Doppler, M-mode, phonocardiography, auxiliary and ECG signals. We found long time delays of up to 90 ms in one system, whereas delays were mostly short in the two other systems. The time delays varied relative to system settings. Consequently, to avoid these errors, precise knowledge of the characteristics of the system being used is essential.

Blood Flow Velocity↗