PubMed Health⌕ Search

Biomedical subjects

Per E Jørgensen

Publications and source records attributed to Per E Jørgensen.

6 recordsLinked to original sources

Serum protein profiling by miniaturized solid-phase extraction and matrix-assisted laser desorption/ionization mass spectrometry.

Serum profiling by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) holds promise as a clinical tool for early diagnosis of cancer and other human diseases. Sample preparation is key to achieving reproducible and well-resolved signals in MALDI-MS; a prerequisite for translation of MALDI-MS based diagnostic methods to clinical applications. We have investigated a number of MALDI matrices and several miniaturized solid-phase extraction (SPE) methods for serum protein concentration and desalting with the aim of generating reproducible, high-quality protein profiles by MALDI-MS. We developed a simple protocol for serum profiling that combines a matrix mixture of 2,5-dihydroxybenzoic acid and alpha-cyano-4-hydroxycinnamic acid with miniaturized SPE and MALDI-MS. Functionalized membrane discs with hydrophobic, ion-exchange or chelating properties allowed reproducible MALDI mass spectra (m/z 1000-12,000) to be obtained from serum. In a proof-of-principle application, SPE with chelating material and MALDI-MS identified protein peaks in serum that had been previously reported for distinguishing a person diagnosed with breast cancer from a control. These preliminary results indicate that this simple SPE/MALDI-MS method for serum profiling provides a versatile and scalable platform for clinical proteomics.

Blood Proteins↗

Reference change values and power functions.

Repeated samplings and measurements in the monitoring of patients to look for changes are common clinical problems. The "reference change value", calculated as zp x [2 x (CVI2 + CVA2)](1/2), where zp is the z-statistic and CVI and CVA are within-subject and analytical coefficients of variation, respectively, has been used to detect whether a measured difference between measurements is statistically significant. However, a reference change value only detects the probability of false-positives (type I error), and for this reason, a model to calculate the risk of missing significant changes in serial results from individuals (probability of false-negatives) is investigated in this work by means of power functions. Therefore, when an analyte is being monitored in a patient, power functions estimate the probability of detecting a defined real change by measuring the difference. Thus, when a measured difference is the same as the calculated reference change value, then it will be detected in only 50% of situations.

Analysis of Variance↗