PubMed Health⌕ Search

Biomedical subjects

Per Håkansson

Publications and source records attributed to Per Håkansson.

18 recordsLinked to original sources

Solution-phase deuterium/hydrogen exchange at a specific residue using nozzle-skimmer and electron capture dissociation mass spectrometry.

Information about protein conformation can be obtained with hydrogen/deuterium exchange (HDX) mass spectrometry. The isotopic solution-phase exchange of specific amide hydrogen atoms can be followed using low-vacuum nozzle-skimmer collision-induced dissociation (CID). In this study, the nozzle-skimmer technique was complemented by electron capture dissociation (ECD) Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS). The solution-phase exchange at a specific residue is monitored by comparing isotopic distributions of two consecutive b- or c-type ions. While nozzle-skimmer fragmentation takes place in the low-vacuum region of the mass spectrometer, ECD occurs at ultra-high vacuum within the mass analyzer cell of the FTICR mass spectrometer. The dissociations take place at 10(-4) and 10(-9) mbar, respectively. Low-vacuum nozzle-skimmer fragmentation can result in intramolecular exchange between product ions and solvent molecules in the gas phase. Consequently, the solution-phase information about protein or peptide conformation is lost. It was not possible to monitor isotopic solution-phase exchange at the eighth residue in substance P, (Phe)8, with nozzle-skimmer CID. By using the in-cell ECD fragmentation method, the solution-phase exchange at the (Phe)8 residue was preserved during mass spectrometric analysis. This result shows the complementary aspects of applying fragmentation at low and at high vacuum, when studying isotopic exchange in solution at specific residues using FTICRMS.

Deuterium Exchange Measurement↗

Peptide and protein characterization by high-rate electron capture dissociation Fourier transform ion cyclotron resonance mass spectrometry.

The analytical utility of the electron capture dissociation (ECD) technique, developed by McLafferty and co-workers, has substantially improved peptide and protein characterization using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The limitations of the first ECD implementations on commercial instruments were eliminated by the employment of low-energy electron-injection systems based on indirectly heated dispenser cathodes. In particular, the ECD rate and reliability were greatly increased, enabling the combination of ECD/FTICR-MS with on-line liquid separation techniques. Further technique development allowed the combination of two rapid fragmentation techniques, high-rate ECD and infrared multiphoton dissociation (IRMPD), in a single experimental configuration. Simultaneous and consecutive irradiations of trapped ions with electrons and photons extended the possibilities for ion activation/dissociation and led to improved peptide and protein characterization. The application of high-rate ECD/FTICR-MS has demonstrated its power and unique capabilities in top-down sequencing of peptides and proteins, including characterization of post-translational modifications, improved sequencing of peptides with multiple disulfide bridges and secondary fragmentation (w-ion formation). Analysis of peptide mixtures has been accomplished using high-rate ECD in bottom-up mass spectrometry based on mixture separation by liquid chromatography and capillary electrophoresis. This paper summarizes the current impact of high-rate ECD/FTICR-MS for top-down and bottom-up mass spectrometry of peptides and proteins.

Animals↗

Cerebrospinal fluid protein patterns in neurodegenerative disease revealed by liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometry.

This study demonstrates the power of a novel proteomic approach developed for the detection and identification of biological markers in body fluids. The goal was to observe alterations in the protein patterns of cerebrospinal fluid (CSF) related to amyotrophic lateral sclerosis (ALS), a neurodegenerative disorder with unknown etiology. In the experiments, tryptic digests of CSF from patients and healthy controls were analyzed by on-line capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometry. (FT-ICR MS) Typically, around 4000 peptides were detected in one such experiment, and a pattern recognition program was constructed for the data analysis to distinguish mass chromatograms from patients and controls. This strategy was evaluated comparing the peptide patterns of CSF spiked in vitro with a biomarker, with control CSF. The patterns were clearly separated and the tryptic peptides of the biomarker were successfully selected as characteristic peaks. Hence, the method was applied to compare mass chromatograms of CSF from 12 ALS-patients and 10 matched healthy controls. While no biomarker alone could be identified from the characteristic peaks, we were able to assign 4 out of 5 unknown samples correctly (i.e., 80% correctly diagnosed, 20% false-negative), and it would be 100% if we reject a possible outlier believed to be caused by an occlusion in the spinal CSF compartment. These findings are very promising, although the clinical relevance is not fully established due to the low number of unknown samples analyzed. In addition to the diagnostic potential, these results may be important steps towards understanding the neurodegenerative process.

Adult↗

Electron capture dissociation Fourier transform ion cyclotron resonance mass spectrometry in the electron energy range 0-50 eV.

Electron capture dissociation (ECD) of polypeptide cations was obtained with pencil and hollow electron beams for both sidekick and gas-assisted dynamic ion trapping (GADT) using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) with an electrostatic ion transfer line. Increasing the number of trapped ions by multiple ICR trap loads using GADT improved the ECD sensitivity in comparison with sidekick ion trapping and ECD efficiency in comparison with single ion trap load by GADT. Furthermore, enhanced sensitivity made it possible to observe ECD in a wide range of electron energies (0-50 eV). The degree, rate and fragmentation characteristics of ECD FTICR-MS were investigated as functions of electron energy, electron irradiation time, electron flux and ion trapping parameters for this broad energy range. The results obtained show that the rate of ECD is higher for more energetic (>1 eV) electrons. Long electron irradiation time with energetic electrons reduces average fragment ion mass and decreases efficiency of formation of c- and z-type ions. The obtained dependencies suggest that the average fragment ion mass and the ECD efficiency are functions of the total fluence of the electron beam (electron energy multiplied by irradiation time). The measured electron energy distributions in low-energy ECD and hot ECD regimes are about 1 eV at full width half maximum in employed experimental configurations.

Electrons↗

Shifted-basis technique improves accuracy of peak position determination in Fourier transform mass spectrometry.

The present paper suggests a new algorithm for estimation of peak positions in FTMS spectra. It is shown theoretically and experimentally that the new technique yields superior results compared to the currently applied techniques, when the noise level is high and/or the peaks are located close to each other. Cases are presented where the deviation from the true mass could be mistaken for space charge effect, while the shift is in fact solely due to the shortcomings of the current techniques and can be corrected by applying the shifted-basis technique. In two out of three cases, this technique gave more accurate (>5 times) result compared to the conventional analysis. In the third case, where the signal was high compared to the noise, the results were comparable. The new technique can be used to achieve better mass accuracy for noisy and not well resolved spectra, and to further investigate the features of the space charge effect.

Algorithms↗

Inter-molecular migration during collisional activation monitored by hydrogen/deuterium exchange FT-ICR tandem mass spectrometry.

The difficulty with integrating solution-phase hydrogen/deuterium exchange (HDX) and tandem mass spectrometry is that the energy added to cause fragmentation might promote gas-phase migration of the added deuterium atoms. Here, we compare the solution-phase HDX profiles generated from a- b- and y-type fragment ion series originating from capillary-skimmer dissociation. The isotopic distributions of fragments from the different fragment ion types were used to determine the isotopic state of the amide hydrogen within a specific residue. Even though the same amide hydrogen was examined, the result was different for different fragment ion types. This observation indicates that different fragment series are not equally subjected to inter-molecular migration during collision-induced dissociation (CID). We also investigated the gas-phase reactivity of originally undeuterated CID fragments of penta-phenylalanine using gas-phase HDX in an external accumulation hexapole. The incorporation of deuterium into the different fragments was studied as a function of hexapole pressure. It was found that different b- and y-ions from the same peptide had different gas-phase reactivity. However, the a-ions did not display significant gas-phase reactivity. The observed behavior has significant impact on any method that involves comparing the isotopic distributions of different fragment ions. Great care has to be taken in the interpretation of the HDX data using CID to increase the spatial resolution. The isotopic state observed after solution-phase exchange might be more preserved for some CID-fragment types.

Amino Acid Sequence↗

Localized changes in the structural stability of myoglobin upon adsorption onto silica particles, as studied with hydrogen/deuterium exchange mass spectrometry.

A new method is presented for monitoring the conformational stability of various parts of a protein that is physically adsorbed onto nanometer-sized silica particles. The method employs hydrogen/deuterium (H/D) exchange of amide hydrogens, a process that is extremely sensitive to structural features of proteins. The resulting mass increase is analyzed with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry. Higher structural specificity is obtained by enzymatically cleaving the adsorbed proteins prior to mass spectrometric analysis. The mass increases of four peptic fragments of myoglobin are followed as a function of the H/D exchange time. The four peptic fragments cover 90% of the myoglobin structure. Two of the peptic fragments, located in the middle of the myoglobin sequence and close to the heme group, do not show any adsorption-induced changes in their structural stability, whereas the more stable C- and N-terminal fragments are destabilized. Interestingly, for the N-terminal fragment, comprising residues 1-29, two distinct and equally large conformational populations are observed. One of these populations has a stability similar to that in solution (-23 kJ/mol), whereas the other population is highly destabilized upon adsorption (-11 kJ/mol).

Adsorption↗

Protein identification in cerebrospinal fluid using packed capillary liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry.

The identification and characterization of proteins in complex biological samples such as body fluids, require powerful and reliable tools. Mass spectrometry is today one of the most important methods in such research. This paper reports on the results from the first experiment where a tryptic digest of cerebrospinal fluid was analyzed applying reversed phase liquid chromatography coupled on-line to a 9.4 T Fourier transform ion cyclotron resonance mass spectrometer. In total, 70 204 peaks were detected, which originated from 16 296 isotopic clusters corresponding to 6551 unique peptide masses. From these masses, 39 proteins were identified in the sample. The amount of sample required for one experiment corresponds to 32 microL of cerebrospinal fluid.

Biophysics↗

Combined infrared multiphoton dissociation and electron capture dissociation with a hollow electron beam in Fourier transform ion cyclotron resonance mass spectrometry.

An electron injection system based on an indirectly heated ring-shaped dispenser cathode has been developed and installed in a 7 Tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. This new hardware design allows high-rate electron capture dissociation (ECD) to be carried out by a hollow electron beam coaxial with the ion cyclotron resonance (ICR) trap. Infrared multiphoton dissociation (IRMPD) can also be performed with an on-axis IR-laser beam passing through a hole at the centre of the dispenser cathode. Electron and photon irradiation times of the order of 100 ms are required for efficient ECD and IRMPD, respectively. As ECD and IRMPD generate fragments of different types (mostly c, z and b, y, respectively), complementary structural information that improves the characterization of peptides and proteins by FTICR mass spectrometry can be obtained. The developed technique enables the consecutive or simultaneous use of the ECD and IRMPD methods within a single FTICR experimental sequence and on the same ensemble of trapped ions in multistage tandem (MS/MS/MS or MS(n)) mass spectrometry. Flexible changing between ECD and IRMPD should present advantages for the analysis of protein digests separated by liquid chromatography prior to FTICRMS. Furthermore, ion activation by either electron or laser irradiation prior to, as well as after, dissociation by IRMPD or ECD increases the efficiency of ion fragmentation, including the w-type fragment ion formation, and improves sequencing of peptides with multiple disulfide bridges. The developed instrumental configuration is essential for combined ECD and IRMPD on FTICR mass spectrometers with limited access into the ICR trap.

Animals↗

A novel mass spectrometric approach to the analysis of hormonal peptides in extracts of mouse pancreatic islets.

Liquid chromatography mass spectrometry (LC-MS) is a valuable tool in the analysis of proteins and peptides. The combination of LC-MS with different fragmentation methods provides sequence information on components in complex mixtures. In this work, on-line packed capillary LC electrospray ionization Fourier transform ion cyclotron resonance MS was combined with two complementary fragmentation techniques, i.e. nozzle-skimmer fragmentation and electron capture dissociation, for the determination of hormonal peptides in an acid ethanol extract of mouse pancreatic islets. The most abundant peptides, those derived from proinsulin and proglucagon, were identified by their masses and additional sequence-tag information established their identities. Interestingly, the experiments demonstrated the presence of truncated C-peptides, des-(25-29)-C-peptide and des-(27-31)-C-peptide. These novel findings clearly illustrate the potential usefulness of the described technique for on-line sequencing and characterization of peptides in tissue extracts.

Animals↗

Prediction of chromatographic retention and protein identification in liquid chromatography/mass spectrometry.

Liquid chromatography coupled on- or off-line with mass spectrometry is rapidly advancing as a tool in proteomics capable of dealing with the inherent complexity in biology and complementing conventional approaches based on two-dimensional gel electrophoresis. Proteins can be identified by proteolytic digestion and peptide mass fingerprinting or by searching databases using short-sequence tags generated by tandem mass spectrometry. This paper shows that information on the chromatographic behavior of peptides can assist protein identification by peptide mass fingerprinting in liquid chromatography/mass spectrometry. This additional information is significant and already available at no extra experimental cost.

Amino Acids↗

Ionization energies of multiply protonated polypeptides obtained by tandem ionization in Fourier transform mass spectrometers.

Ionization energies (IE) of [M + zH](z+) (z+) electrospray-produced polypeptides were determined by electron ionization in a Penning cell of 4.7 and 9.4 T Fourier transform mass spectrometers. For z = 1+ and substance P, the found IE value of 11.0 +/- 0.4 eV is in agreement with that obtained earlier for ions generated with matrix-assisted laser desorption/ionization. For higher z, the following values were found: 11.7 +/- 0.3 eV for 2+ of [Arg-8]-vasopressin, 11.1 +/- 0.6 eV for 2+ of substance P, 12.2 +/- 0.7 eV for 2+ of renin substrate, 13.3 +/- 0.4 eV for 3+ of B-chain of insulin and 14.6 +/- 0.6 eV for 4+ and 15.1 +/- 0.4 eV for 5+ of melittin. It was found that 90% of existing IE data on polypeptides in the 1.0-3.5 kDa mass range are described with <or=0.5 eV uncertainty by the empirical equation IE(z) = 9.8 + 1.1z. The average IE increase of 1.1 eV/charge is attributed to Coulombic repulsion. The deduced ionization energy of a neutral polypeptide molecule, 9.8 +/- 0.3 eV, is consistent with literature expectations.

Angiotensinogen↗

Liquid chromatography and electron-capture dissociation in Fourier transform ion cyclotron resonance mass spectrometry.

Liquid separation methods in combination with electrospray mass spectrometry as well as the recently introduced fragmentation method electron capture dissociation (ECD) have become powerful tools in proteomics research. This paper presents the results of the first successful attempts to combine liquid chromatography (LC) and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) with ECD in the analysis of a mixture of standard peptides and of a bovine serum albumin tryptic digest. A novel electron injection system provided conditions for ECD sufficient to yield extensive sequence information for the most abundant peptides in the mixtures on the time-scale of the chromatographic separation. The results suggest that LC/ECD-FTICRMS can be employed in the characterization of peptides in enzymatic digests of proteins or protein mixtures and identify and localize posttranslational modifications.

Chromatography, Liquid↗

Peptide mapping of proteins in human body fluids using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

Human body fluids have been rediscovered in the post-genomic era as great sources of biological markers and perhaps particularly as sources of potential protein biomarkers of disease. Analytical tools that allow rapid screening, low sample consumption, and accurate protein identification are of great importance in studies of complex biological samples and clinical diagnosis. Mass spectrometry is today one of the most important analytical tools with applications in a wide variety of fields. One of the fastest growing applications is in proteomics, or the study of protein expression in an organism. Mass spectrometry has been used to find post-translational modifications and to identify key functions of proteins in the human body. In this study, we review the use of human body fluids as sources for clinical markers and present new data that show the ability of Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) to identify and characterize proteins in four human body fluids: plasma, cerebrospinal fluid (CSF), saliva, and urine. The body fluids were tryptically digested without any prior separation, purification, or selection, and the digest was introduced into a 9.4 T FTICR mass spectrometer by direct-infusion electrospray ionization (ESI). Even though these samples represent complex biological mixtures, the described method provides information that is comparable with traditional 2D-PAGE data. The sample consumption is extremely low, a few microliters, and the analysis time is only a few minutes. It is, however, evident that the separation of proteins and/or peptides must be included in the methodology, in order to detect low-abundance proteins and other proteins of biological relevance.

Biomarkers↗

Rapid analysis of tryptically digested cerebrospinal fluid using capillary electrophoresis-electrospray ionization-Fourier transform ion cyclotron resonance-mass spectrometry.

Mass spectrometry has in recent years been established as the method of choice for protein identification and characterization in proteomics. Capillary electrophoresis (CE) is a fast and efficient method for the separation of peptides and proteins. The on-line combination of CE with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) has been shown to be a powerful tool in the analysis of complex mixtures of proteins. This paper presents the first results from a proteomic analysis of human cerebrospinal fluid proteins by tryptic digestion and CE-FTICR-MS, where 30 proteins could be identified on a 95% confidence level with mass measurement errors less than 5 ppm.

Cerebrospinal Fluid↗

Quantitative analysis of tryptic protein mixtures using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

For the first time, quantitative analysis of tryptic protein mixtures, labeled with Quantification-Using-Enhanced-Signal-Tags (QUEST)-markers, were performed with electrospray ionization and a 9.4 T Fourier Transform Ion Cyclotron Resonance (FTICR) mass spectrometer. Coupling a High-Pressure Liquid Chromatography (HPLC) separation step prior to mass analysis resulted in an increased amount of identified labeled tryptic peptides. The range for the determined intensity ratios of two peptides in a labeled pair was large, but the obtained median intensity ratio correlated very well with the corresponding concentration ratio. This method can be used for observing protein dynamics in a specific cell type, tissue, or in body fluids.

Animals↗

Reproducibility of tryptic digestion investigated by quantitative fourier transform ion cyclotron resonance mass spectrometry.

In this study, the reproducibility of tryptic digestion of complex solutions was investigated using liquid chromatography Fourier transform ion cyclotron resonance (LC FT-ICR) mass spectrometry. Tryptic peptides, from human cerebrospinal fluid, (CSF) were labeled with Quantification-Using-Enhanced-Signal-Tags (QUEST)-markers, or 1-([H4]nicotinoyloxy)- and 1-([D4]nicotinoyloxy)-succinimide ester markers. The analysis was performed on abundant proteins with respect-to-intensity ratios and sequence coverage and obtained by comparing differently labeled components from one or different pools. To interpret the dynamics in the proteome, one must be able to estimate the error introduced in each experimental steps. The intra sample variation due to derivatization was approximately 10%. The inter sample variation depending on derivatization and tryptic digestion was not more than approximately 30%. These experimental observations provide a range for the up- and down-regulations that are possible to study with electrospray ionization LC FT-ICR mass spectrometry.

Adolescent↗

Depletion of high-abundant proteins in body fluids prior to liquid chromatography fourier transform ion cyclotron resonance mass spectrometry.

Today, proteomics is an exciting approach to discover potential biomarkers of different disorders. One challenge with proteomics experiments is the wide concentration range of proteins in various tissues and body fluids. The most abundant component in human body fluids, human serum albumin (HSA), is present at concentrations corresponding to approximately 50% of the total protein content in, e.g., plasma and cerebrospinal fluid (CSF). If this component could be selectively removed, then the chances of observing lower-abundance component of clinical interest would be greatly improved. There are today several approaches of varying specificity available for depletion. In this study, the properties of two commercially available kits, for the removal of HSA and HSA and immunoglobulin G (IgG), respectively, were compared, and the benefits of using depletion steps prior to on-line LC-FTICR MS were evaluated. Both methods were applied on plasma and CSF. To our knowledge, these are the first results reported for CSF. Also, the combination with electrospray LC-FTICR MS is novel. The proportion of depleted HSA and IgG was estimated using global labeling markers for peptide quantification. Both depletion-methods provided a significant reduction of HSA, and the identification of lower abundant components was clearly facilitated. A higher proportion of HSA was removed using the affinity-based removal kit, and consequently more proteins could be identified using this approach.

Adult↗