PubMed Health⌕ Search

Biomedical subjects

Per Thyberg

Publications and source records attributed to Per Thyberg.

6 recordsLinked to original sources

FCS cell surface measurements--photophysical limitations and consequences on molecular ensembles with heterogenic mobilities.

BACKGROUND: Fluorescence Correlation Spectroscopy is a powerful method to analyze densities and diffusive behavior of molecules in membranes, but effects of photodegradation can easily be overlooked. METHOD: Based on experimental photophysical parameters, calculations were performed to analyze the consequences of photobleaching in fluorescence correlation spectroscopy (FCS) cell surface experiments, covering a range of standard measurement conditions. RESULTS: Cumulative effects of photobleaching can be prominent, although an absolute majority of the fluorescent molecules would pass the laser excitation beam without being photo-bleached. Given a distribution of molecules on a cell surface with different diffusive properties, the fraction of molecules that is actually analyzed depends strongly on the excitation intensities and measurement times, as well as on the size of the reservoir of freely diffusing molecules. Both the slower and the faster diffusing molecules can be disfavored. CONCLUSIONS: Apart from quantifying photobleaching effects, the calculations suggest that the effects can be used to extract additional information, for instance about the size of the reservoirs of free diffusion. By certain choices of measurement conditions, it may be possible to more specifically analyze certain species within a population, based on their different diffusive properties, different areas of free diffusion, or different kinetics of possible transient binding.

Animals↗

Direct quantification of mRNA expression levels using single molecule detection.

Determination of the gene expression by direct quantification of mRNA is becoming increasingly important in basic, pharmaceutical and clinical research. We present a novel approach for gene quantification based on direct hybridization of gene-specific probes to target mRNA sequences in solution at temperatures ensuring absolute specificity of the probe-target complex. No enzymatic steps like reverse transcription or amplification by PCR are involved within the quantification process. In order to increase specificity as well as sensitivity, two probes emitting fluorescence light in different colors are used for our homogeneous assay using fluorescence cross-correlation. We relate to the single molecule sensitivity of excitation and detection in confocal cavities avoiding the amplification of the detected signal. The analysis of the expression level of high, medium and low abundant genes is described in two different cell lines, whereby the genes are quantified in absolute numbers.

Calcium-Binding Proteins↗

Specifically associated PCR products probed by coincident detection of two-color cross-correlated fluorescence intensities in human gene polymorphisms of methylene tetrahydrofolate reductase at site C677T: a novel measurement approach without follow-up mathematical analysis.

Whole blood samples of known methylene tetrahydrofolate reductase (MTHFR) genotypes from 24 individuals were examined at site C677T. Their amplified DNA products were assessed by two-color fluorescence cross-correlation measurements and agarose gel electrophoresis/capillary gel electrophoresis. DNA subpopulations were identified which were not associated with the proper genotype by primer combinations and cycling conditions called multiplexes. We confirmed that DNA analysis by two-color fluorescence cross-correlation measurements allowed the detection of fluorescence signals specifically associated with the proper genotypes in a mixture of amplified nontarget DNA molecules without DNA sizing. The measurement approach does not require complex, follow-up mathematical analysis and is applicable to any single nucleotide polymorphisms. The simple immunogenetic model showed how the approach works to reveal specific DNA target by preventing detection of nontarget DNA. Under those experimental conditions, a new ultrasensitive, and specific method for clinical immunologists is born.

DNA↗

Gene expression analysis using single molecule detection.

Recent developments of single molecule detection techniques and in particular the introduction of fluorescence correlation spectroscopy (FCS) led to a number of important applications in biological research. We present a unique approach for the gene expression analysis using dual-color cross-correlation. The expression assay is based on gene-specific hybridization of two dye-labeled DNA probes to a selected target gene. The counting of the dual-labeled molecules within the solution allows the quantification of the expressed gene copies in absolute numbers. As detection and analysis by FCS can be performed at the level of single molecules, there is no need for any type of amplification. We describe the gene expression assay and present data demonstrating the capacity of this novel technology. In order to prove the gene specificity, we performed experiments with gene-depleted total cDNA. The biological application was demonstrated by quantifying selected high, medium and low abundant genes in cDNA prepared from HL-60 cells.

Actins↗

C677T single nucleotide polymorphisms of the human methylene tetrahydrofolate reductase and specific identification : a novel strategy using two-color cross-correlation fluorescence spectroscopy.

BACKGROUND: A methylene tetrahydrofolate reductase (MTHFR) deficiency at site C677T renders the enzyme thermolabile and consequently represents a risk factor for vascular disease, neural tube defects, preeclampsia, and thrombosis. Highly specific identification techniques for genotyping are mandatory to give guidance for the diagnosis and monitoring of this deficiency. METHODS: A new approach for performing genotyping has been introduced with the identification of single nucleotide polymorphisms of the human MTHFR. It is based on PCR followed by two-color cross-correlation fluorescence spectroscopy (FCS). Experiments were carried out with green- and red-tagged allele-specific primers, which were fully compatible with the two-color fluorescence cross-correlation setup at 488 nm and 633 nm excitation wavelengths. RESULTS: The measured data of the amplification mixes (tubes) were normalized as the maximum correlation amplitude of each tube. Correlated and uncorrelated data were optically separated in the amplification mixes by their characteristic correlation times, which significantly differed from each other. The correlated data were generated in the presence of the proper mutated genotype template, whereas uncorrelated data were due to the absence of the proper genotype template. Furthermore, the specific association of the two-color fluorescence correlated signals with the target DNA was experimentally proven. Using this novel two-color cross-correlation approach, the MTHFR genotypes, which were determined in 21 clinical samples, showed concordance with methods involving a PCR-based assay with hexachloro-6-carboxy-fluorescein (HEX)- and 6-carboxy-fluorescein (FAM)-tagged allele-specific primers and a subsequent separation step with capillary electrophoresis, yet are simpler to perform. There was no evidence of a central trend of false-positive or false-negative results. We demonstrated how the novel, ultrasensitive typing system could be applied to studies where researchers are trying to perfect their assays and are often working with the unknown, or application to problematic assays in a clinical environment for those involved in molecular diagnosis. CONCLUSIONS: We present an alternative method to those commonly used in genotyping. Two-color cross-correlation FCS allows the detection of the fluorescence signals specifically associated with the heterozygous mutated, the homozygous mutated, and normal individuals, as exemplified in this study. The presence of nonspecific amplification products, which interfere with subsequent DNA analysis, could therefore highlight the need for two-color cross-correlation FCS as a means of discriminating between specific association of the fluorescence signals with the target DNA and DNA not related to the target.

Base Sequence↗

Parallel dual-color fluorescence cross-correlation spectroscopy using diffractive optical elements.

Dual-color cross-correlation spectroscopy allows the detection and quantification of labeled biomolecules at ultra-low concentrations, whereby the sensitivity of the assay correlates with the measurement time. We now describe a parallel multifocal dual-color spectroscopic configuration employing multiple avalanche photodiodes and hardware correlators. Cross-correlation curves are obtained from several dual-color excitation foci simultaneously. Multifocal dual-color excitation is achieved by splitting each of two laser beams (488 and 633 nm) into four sub-beams with the help of two 2x2 fan-out diffractive optical elements (DOEs), and subsequent superposition of the two sets of four foci. The fluorescence emission from double-labeled biomolecules is detected by two 2x2 fiber arrays.

Equipment Design↗