PubMed Health⌕ Search

Biomedical subjects

Pertti Törmälä

Publications and source records attributed to Pertti Törmälä.

At least 19 recordsLinked to original sources

In vitro and in vivo testing of bioabsorbable antibiotic containing bone filler for osteomyelitis treatment.

The use of local antibiotics from a biodegradable implant is appealing concept for treatment of chronic osteomyelitis. Our aim was to develop a new drug delivery system based on controlled ciprofloxacin release from poly(D/L-lactide). Cylindrical composite pellets (1.0 x 0.9 mm) were manufactured from bioabsorbable poly(D/L-lactide) matrix and ciprofloxacin (7.4 wt %). In vitro studies were carried out to delineate the release profile of the antibiotic and to verify its antimicrobial activity by means of MIC testing. A long-term study in rabbits was performed to validate the release of ciprofloxacin from the composite in vivo. Therapeutic level of ciprofloxacin (>2 microg/mL) was maintained between 60 and 300 days and the concentration remained below the potentially detrimental level of 20 microg/mL in vitro. The released ciprofloxacin had retained its antimicrobial properties against common pathogens. In an exploratory long-term in vivo study with three rabbits, ciprofloxacin could not be detected from the serum after moderate filling (160 mg) of the tibia (follow-up 168 days), whereas after high dosing (a total dose of 1,000 mg in both tibias) ciprofloxacin was found temporarily at low serum concentrations (14-34 ng/mL) during the follow-up of 300 days. The bone concentrations of ciprofloxacin could be measured in all samples at 168 and 300 days. The tested copolylactide matrix seems to be a promising option in selection of resorbable carriers for sustained release of antibiotics, but the composite needs modifications to promote ciprofloxacin release during the first 60 days of implantation.

Absorbable Implants↗

Fibre reinforced bioresorbable composites for spinal surgery.

Composites containing different amounts of beta-tricalcium phosphate (beta-TCP) embedded in a poly-lactide (PLA70) matrix with and without poly-lactide (PLA96) fibre reinforcement were studied and the feasibility of using these composites in spinal fusion implants was examined. Compressive yield strength was measured in two directions: parallel to (83-97 MPa) and perpendicular to (108-123 MPa) the laminated structure of the composites. In the parallel direction, the addition of beta-TCP decreased compressive yield strength while in the perpendicular direction this was increased when compared to plain specimens (p<0.05). Fibre reinforcement had no significant effect on compressive yield strength (p<0.05), but did increase impact strength by 127-216% for notched specimens (parallel direction) and by about 65% for un-notched specimens (perpendicular direction) (p<0.05). A 24 week in vitro analysis of implant prototypes in simulated body fluid revealed a decrease in compressive yield strength, which was greater for the samples containing 50 wt.% beta-TCP than for those containing 25 wt.% beta-TCP. After 12 weeks incubation the composites retained 66-99% of their initial compressive strength, depending on composition. After 24 weeks incubation the lowest compressive strength was 51% (56 MPa: 50/50) and the highest was 94% (90 MPa: 75/25) of the initial value. Calcium phosphate precipitation on the surfaces of the materials in vitro was also observed. The initial compressive strengths of the studied composites were comparable to materials used in spinal fusion applications, but adequate strength retention behaviour needs to be confirmed before undertaking clinical experiments.

Biocompatible Materials↗

Ciprofloxacin-releasing bioabsorbable polymer is superior to titanium in preventing Staphylococcus epidermidis attachment and biofilm formation in vitro.

Antibiotic coating systems have been successfully used to prevent bacterial attachment and biofilm formation. Our purpose was to evaluate whether bioabsorbable polylactide-co-glycolide (PLGA) 80/20 on its own, and PLGA together with ciprofloxacin (PLGA+C) have any advantages over titanium in preventing Staphylococcus epidermidis attachment and biofilm formation in vitro. Cylindrical specimens of titanium, PLGA, and PLGA+C in triplicate were examined for S. epidermidis ATCC 35989 attachment and biofilm formation after incubation with a bacterial suspension of about 10(5) cfu/mL for 1, 3, 7, 14, and 21 days, using scanning electron microscopy. Growth inhibition properties of PLGA and PLGA+C cylinders were tested on agar plates. On days 1, 3, and 21, no bacterial attachment was seen in 19.5, 9.2, and 41.4% of the titanium specimens; in 18.4, 28.7, and 34.5% of the PLGA specimens; and in 57.5, 62.1, and 57.5% of the PLGA+C specimens, respectively. During the whole study period, no biofilm was observed on 74-93% of the titanium specimens, 58-78% of the PLGA specimens, and 93-100% of the PLGA+C specimens. PLGA+C showed clear bacterial growth inhibition on agar plates, while PLGA and titanium did not show any inhibition. PLGA+C bioabsorbable material was superior to titanium in preventing bacterial attachment and biofilm formation and may have clinical applicability, for example, in prevention of infection in trauma surgery or in the treatment of chronic osteomyelitis.

Anti-Bacterial Agents↗

Release of diclofenac sodium from polylactide-co-glycolide 80/20 rods.

Due to inflammatory reactions complicating bioabsorbable devices, the aim of this study was to develop and characterize bioabsorbable implants with anti-inflammatory drug releasing properties. Polylactide-co- glycolide (PLGA) 80/20 was compounded with diclofenac sodium (DS) to produce rods. Thermal properties were analyzed using differential scanning calorimetry (DSC). Inherent viscosity (eta(inh)) was measured to evaluate the drug effect on the extrude polymer. Drug release measurements were performed using UV-spectrophotometer. Five parallel samples from each type of rods were examined, first at 6 hour intervals, then on daily basis, and later twice a week. DS was released in 110 days from thinner rods and in 150 days from thicker rods. Drug release comprised a starting peak, slow release phase, then a high release phase, and a burst release phase. DSC analysis showed that DS containing rods had crystallinity in their structure. In conclusions, it is feasible to combine PLGA 80/20 and DS by using melt extrusion. Released DS concentrations reached local therapeutic levels, but the release profile was complex and therapeutic levels were not reached all the time.

Anti-Inflammatory Agents, Non-Steroidal↗

Tissue reactions to bioabsorbable ciprofloxacin-releasing polylactide-polyglycolide 80/20 screws in rabbits' cranial bone.

The aim of this study was to assess tissue reactions to bioabsorbable self-reinforced ciprofloxacin-releasing polylactide/polyglycolide (SR-PLGA) 80/20 screws in rabbits' cranial bone. Two screws were implanted in each rabbit, one screw on either side of the sagittal suture (n = 28 rabbits). Animals were sacrificed after 2, 4, 8, 16, 24, 54 and 72 weeks, four animals per group. On histological examination the number of macrophages, giant cells, active osteoblasts and fibrous tissue layers were assessed and degradation of the screws was evaluated. At 2 weeks, the highest number of macrophages and giant cells were seen near the heads of the screws. After 4 and 8 weeks, the number of giant cells decreased but that of macrophages decreased from 16 weeks and on. Screws were surrounded by fibrous tissue capsule that progressively was growing in thickness by time. Active osteoblasts were seen around the shaft of the screws with the highest number seen at 4 weeks postoperatively. At 16 weeks, compact fragmentation of the screw heads was seen with macrophages seen inside the screw matrices. After 24 weeks, no polarization of the screws was seen. After one year, PLGA screws had been replaced by adipose tissue, fibrous tissue and "foamy macrophages" which had PLGA particles inside them. After 1(1/2) years, the amount of biomaterial remaining had decreased remarkably. The particles of biomaterial were inside "foamy macrophages." Ciprofloxacin-releasing SR-PLGA 80/20 screws elicited a mild inflammatory reaction but did not interfere with osteoblast activity. No complications were seen when implanted in cranial bone of rabbit.

Animals↗

Self-reinforced ciprofloxacin-releasing polylactide-co-glycolide 80/20 inhibits attachment and biofilm formation by Staphylococcus epidermidis: an in vitro study.

We have observed the efficiency of antibiotic-releasing polylactide-co-glycolide (PLGA) 80/20 in preventing Staphylococcus epidermidis attachment and biofilm formation in vitro. The aim of the present study was to evaluate the effect of self-reinforced (SR) implants with enhanced antibiotic release on bacterial attachment and biofilm formation rates, and also on growth inhibition of Staphylococcus epidermidis. Cylindrical SR-PLGA+AB specimens (length 30 mm, diameter 3 mm) were examined by scanning electron microscopy (SEM) for attachment of S. epidermidis ATCC 35989 on biomaterial surface and formation of biofilm, after incubating with bacterial suspension of ca. 10 cfu/mL for 1, 3, 7, 14 and 21 days. SR-PLGA and SR-PLGA+AB implants were tested on agar plates by measuring the inhibition distance around implants. On the surface of SR-PLGA+AB, at days 1, 3, 7, 14 and 21, the percentage of areas with not a single bacteria attached, was 88.6%, 71.1%, 73.7%, 73.7%, and 68.4%, respectively. On the areas where bacteria were detected, the number of bacterial cells remained low during whole study period, and no significant increase by time was seen. There was no biofilm observed on 97-99% of the examined areas during the whole study period on SR-PLGA+AB. In agar plates, the SR-PLGA+AB showed inhibition of bacterial growth, with (mean) 53.2 mm diameter of inhibition area with peeled implants and 50.5 mm with non-peeled implants. There was no inhibition seen around implants without ciprofloxacin. Bioabsorbable ciprofloxacin-releasing self-reinforced PLGA (SR-PLGA+AB) was superior to plain SR-PLGA in preventing bacterial attachment, biofilm formation, and also the growth of Staphylococcus epidermidis.

Anti-Infective Agents↗

Poly-L/D-lactide (PLDLA) 96/4 fibrous implants: histological evaluation in the subcutis of experimental design.

Poly-L/D-lactide (PLDLA) 96/4 fibrous implants have been introduced to engineer functional fibrous constructions in situ. The current study was undertaken to evaluate the guidance of the fibrous tissue formation and the tissue reaction of porous PLDLA 96/4 scaffolds implanted in subcutaneous tissue. Three various PLDLA 96/4 knitted-mesh scaffolds (Loose, Ordinary, and Dense) were implanted subcutaneously in 32 rats, and followed-up from 3 days until 48 weeks postsurgery. Histological examination showed that PLDLA 96/4 scaffolds provided a structurally supporting element for 48 weeks. They were filled with fibrous tissue by 3 weeks. During the follow-up, loose connective tissue was organized into dense connective tissue with thick collagen bundles. At 48 weeks, no statistically significant difference was found in the amount of loose or dense connective tissue between the scaffold groups of various porosities, although the tendency for higher amounts of loose connective tissue was seen in the Loose type scaffolds. PLDLA filament diameters were 121 mum at 2 weeks, 119 mum at 24 weeks and 116 mum at 48 weeks (P = 0.03 between 2 and 48 weeks). Porous PLDLA scaffold induced fibrous tissue formation in situ. This can be exploited in engineering fibrous tissue constructs in vivo for tissue support or replacement purposes.

Absorbable Implants↗

Biocompatibility properties of a new braided biodegradable urethral stent: a comparison with a biodegradable spiral and a braided metallic stent in the rabbit urethra.

OBJECTIVE: To compare the biocompatibility properties of a new braided biodegradable self-reinforced poly-L-lactic acid (SR-PLLA) urethral stent to the former spiral biodegradable SR-PLLA stent and the stainless steel stent in a rabbit model. MATERIALS AND METHODS: In all, 54 male New Zealand White rabbits were anaesthetized and stents inserted into the prostatic urethra, three of each kind for each sample time. The rabbits were killed after 1, 3, 6, 9, 12 or 15 months and light microscopy and scanning electron microscopy used to analyse the effects. RESULTS: The disintegration of the braided SR-PLLA stent was more closely controlled than that of the spiral SR-PLLA stent. The metallic stent induced epithelial hyperplasia and polyposis earlier than the biodegradable stents, and in these rabbits the polyposis disappeared after the disintegration process. There were no differences in the histological analyses between the biodegradable stents, whereas the metallic stents caused the strongest inflammatory reactions. CONCLUSIONS: The braided SR-PLLA urethral stent functioned well in the rabbit urethra and clinical studies are already planned.

Absorbable Implants↗

In vitro and in vivo release of ciprofloxacin from osteoconductive bone defect filler.

OBJECTIVES: Impregnation of antimicrobial agents within biodegradable carriers with osteoconductive properties could provide the means for one-stage surgical treatment of osteomyelitis. In this study, the in vitro and in vivo antibiotic release from this type of bone defect filler was characterized. METHODS: Cylindrical pellets (2.5 x 1.5 mm) were manufactured from bioabsorbable poly(L-lactide-co-glycolide) (PLGA) matrix, ciprofloxacin [8.3 +/- 0.1% (w/w)] and osteoconductive bioactive glass microspheres (90-125 microm) [27 +/- 2% (w/w)]. In vitro studies were carried out to delineate the release profile of the antibiotic. The antimicrobial activity of the release antibiotic was verified with MIC testing. In a time-sequence study in the rabbit, pellets were surgically implanted in the proximal tibia and the antibiotic concentrations achieved in bone were measured at 1, 2, 3, 4, 5 and 6 months. RESULTS: In vitro elution studies showed sustained release of ciprofloxacin at a therapeutic level (>2 microg/mL) over a time period of 4 months. The released ciprofloxacin had maintained its antimicrobial capacity against five standard ATCC strains. In vivo, the delivery system produced high local bone concentrations (247.9 +/- 91.0 mug/g of bone) for a time period of 3 months with no significant systemic exposure. Histomorphometry and micro-CT imaging confirmed new bone formation around the pellets within 3 months as a sign of an independent osteoconductive property of the composite. CONCLUSIONS: The tested composite seems to be a promising option for local therapy of surgically treated bone infections. The main advantages are the antibiotic release for a definite time period with therapeutic concentrations, which may minimize slow residual release at suboptimal concentrations.

Animals↗

Fixation of distal femoral osteotomies with self-reinforced polymer/bioactive glass rods: an experimental study on rabbits.

Two self-reinforced poly(desamino tyrosyl-tyrosine ethyl ester carbonate), poly(DTE carbonate) or self-reinforced poly(DTE carbonate)/bioactive glass rods, (2 mm by 40 mm) were implanted into the dorsal subcutaneous tissue and osteotomies of the distal femur were fixed with these rods (2 mm by 26 mm) in 36 rabbits. The follow-up times varied from three to 100 weeks. After sacrifice, three-point bending and shear tests and molecular weight measurements were performed for subcutaneously placed rods. Radiological, histological, histomorphometrical, microradiographic, and oxytetracycline-fluorescence studies of the osteotomized and intact control femora were performed. The initial mechanical properties were higher with the SR-poly(DTE carbonate) rods, but the SR-poly(DTE carbonate)/bioactive glass rods lost their mechanical properties slower. At 100 weeks the bending strength had decreased to 21% of the initial value with the SR-poly(DTE carbonate) rods and to 49% with the SR-poly(DTE carbonate)/bioactive glass rods. The shear strength had decreased to 10% with the SR-poly(DTE carbonate) rods and to 23% of the initial value with the SR-poly(DTE carbonate)/bioactive glass rods. Two slight displacements and one delayed union and one failure of fixation were seen in the SR-poly(DTE carbonate) group. In the SR-poly(DTE carbonate)/bioactive glass group five delayed unions and seven slight displacements were seen. No signs of osteolysis or foreign body reactions were observed. Signs of resorption of the implants were seen at 100 weeks in the SR-poly(DTE carbonate)/bioactive glass group. The present investigation showed that the mechanical strength and fixation properties of SR-poly(DTE carbonate) and SR-poly(DTE carbonate)/bioactive glass rods are suitable for fixation of cancellous bone osteotomies in rabbits.

Animals↗

Histologic analysis of bioabsorbable scleral buckling implants: an experimental study on rabbits.

PURPOSE: To analyze histologically tissue reactions to bioabsorbable PLA96 in rabbit eyes. METHODS: Scleral buckling operations were carried out in 48 rabbits. Two materials were used: bioabsorbable PLA96 (polylactide 96/4; L/D molar ratio 96/4) and silicone sponge. One eye of each rabbit was operated on and the other eye served as a nonoperated control. After follow-up times of 1, 3, 5, and 12 months, the rabbits were killed and the eyes enucleated for histology. RESULTS: All rabbits recovered well. Histologically, tissue reactions were very localized; implant fragments were not seen within the sclera. The amounts of fibrous tissue and inflammatory cells (mainly macrophages) inside the implant area increased over time. One rabbit from the silicone group was killed 4 months postoperatively owing to refusal to eat. In the PLA96 group, acute or chronic infections occurred in four rabbits. The bioabsorbable implant was macroscopically easily detectable at 12 months postoperatively. CONCLUSIONS: The PLA96 material used for scleral buckling in rabbits showed good biocompatibility. The material did not undergo biodegradation during the follow-up period of 12 months. PLA96 implants were associated with thicker fibrous tissue encapsulation and more inflammatory cells compared with silicone sponge implants.

Absorbable Implants↗

Biocompatibility and implantation properties of 2 differently braided, biodegradable, self-reinforced polylactic acid urethral stents: an experimental study in the rabbit.

PURPOSE: Biodegradable urethral stents have been in clinical use for more than 10 years. To solve the problems connected with the helical spiral configuration of the stents used to date we developed a new tubular mesh configuration and evaluated the biocompatibility properties and degradation time of 2 differently braided stents in the rabbit urethra. MATERIALS AND METHODS: The biodegradable, self-expanding stents were made of self-reinforced polylactic acid polymer blended with BaSO4 (Alfa Chem, Kings Point, New York). Two braiding patterns, namely a diamond 1/1 and a regular 2/2 + 1 (Prodesco, Perkasie, Pennsylvania), were used to produce a tubular mesh configuration. Stainless steel stents with 1/1 braiding served as controls. The stents were inserted into the posterior urethra of 36 male rabbits. The animals were sacrificed after 1 week, 1 month, 6 months or 12 months. Light microscopy and scanning electron microscopy analyses were done. RESULTS: Tissue reactions to operative trauma were seen in all specimens at week 1. The changes gradually abated in the biodegradable stent groups, whereas chronic inflammatory changes and fibrosis were increasingly seen with metallic stents after 6 months. Epithelial hyperplasia increased with time for all stent types and materials. As expected, stent fragmentation started at 6 months. CONCLUSIONS: Biodegradable polymers are suitable materials for braided urethral stents. However, the braided configuration of the stent with a decreased mass of material does not prevent the development of epithelial hyperplasia. The biodegradable, self-expanding, braided stents functioned well in the rabbit urethra and are suitable for clinical studies.

Absorbable Implants↗

Efficacy of ciprofloxacin-releasing bioabsorbable osteoconductive bone defect filler for treatment of experimental osteomyelitis due to Staphylococcus aureus.

The concept of local antibiotic delivery via biodegradable bone defect fillers with multifunctional properties for the treatment of bone infections is highly appealing. Fillers can be used to obliterate surgical dead space and to provide targeted local bactericidal concentrations in tissue for extended periods. Eventually, the osteoconductive component of the filler could guide the healing of the bone defect. The present experimental study was carried out to test this concept in a localized Staphylococcus aureus osteomyelitis model in the rabbit (n = 31). A metaphyseal defect of the tibia was filled with a block of bone cement, followed by insertion of a bacterial inoculum. After removal of the bone cement and surgical debridement at 2 weeks, the defect was filled with a ciprofloxacin-containing (7.6% +/- 0.1%, by weight) composite (treated-infection group) or with a composite without antibiotic (sham-treated group). Both a positive control group (untreated-infection group) and a negative control group were also produced. The treatment response, monitored by positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose ([18F]FDG) at 3 and 6 weeks, showed rapidly decreasing amounts of [18F]FDG uptake in the treated-infection group (P = 0.001 compared with the results for the untreated-infection group at 6 weeks). The bacteriological analysis confirmed the eradication of the bone pathogen in the treated-infection group. However, three animals had culture-positive soft tissue infections. All animals in the sham-treated and untreated-infection groups had culture-positive bone infections with typical radiographic changes of osteomyelitis. Histomorphometry, peripheral quantitative computed tomography, and backscattered electron imaging of scanning electron microscopy images verified the osteoconductive properties of the bioactive glass microspheres within the composite. The median bone ciprofloxacin concentrations were 1.2 and 2.1 microg/g at two anatomic locations of the tibia. This is the first report to show the value of [18F]FDG PET for quantitative monitoring of the treatment response in bone infections. The collaborative results of bacteriologic and [18F-FDG] PET studies showed that use of the multifunctional composite was successful for eradication of the S. aureus pathogen from bone.

Animals↗

Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70:30 and self-reinforced poly(L/DL)lactide 70: 30/bioactive glass composite rods. an experimental study on rabbits.

Two self-reinforced poly(L/DL)lactide 70:30 or self-reinforced poly (L/DL)lactide 70:30/ bioactive glass (SR-P(L/DL)LA/bioactive glass) composite rods (2 mm x 40 mm) were implanted into the dorsal subcutaneous tissue and osteotomies of the distal femur were fixed with these rods (2 mm x 26 mm) in 36 rabbits. The follow-up times varied from 3 to 100 weeks. After the animals were killed, three-point bending and shear tests and molecular weight measurements were performed for subcutaneously placed rods. Radiological, histological, histomorphometrical, microradiographic and oxytetracycline-fluorescence studies of the osteotomized and intact control femora were performed. After 12 weeks the SR-P(L/DL)LA rods had fragmented into pieces and the mechanical properties could not be measured. The SR-P(L/DL)LA/bioactive glass rods lost their mechanical properties slower, and at 24 weeks the bending strength had decreased by 39% and the shear strength by 50%. After that the mechanical properties of the SR-P(L/DL)LA/bioactive glass rods could not be measured. All osteotomies healed well, and no gross signs of inflammatory reactions were observed. One slight displacement was seen in the three-week follow-up group with SR-P(L/DL)LA rods. Signs of resorption of the implants were seen after 48 weeks in the SR-P(L/DL)LA group and after 24 weeks in the SR-P(L/DL)LA/bioactive glass group. The SR-P(L/DL)LA/bioactive glass rods were almost totally resorbed from the bone at 100 weeks. The present investigation showed that the mechanical strength and fixation properties of the SR-P(L/DL)LA and the SR-P(L/DL)LA/bioactive glass composite rods are suitable for fixation of cancellous bone osteotomies in rabbits.

Animals↗

Drug-eluting biodegradable poly-D/L-lactic acid vascular stents: an experimental pilot study.

PURPOSE: To evaluate in vivo a new drug-eluting biodegradable vascular stent with respect to biocompatibility, neointimal hyperplasia formation, and reliability. METHODS: Self-expanding biodegradable poly-96L/4D-lactic acid (PLA) stents with 2 drugs (PLA + dexamethasone [DEX] and PLA + simvastatin [SIM]) and 2 different coatings (PLA + P(D,L)LA and PLA + polycaprolactone [PCL]) were compared with a self-expanding stainless steel Wallstent. The stents were implanted in both common iliac arteries of 8 pigs. Prior to sacrifice at 1 month, angiography was performed to determine patency. Specimens were harvested for quantitative histomorphometry; vascular injury and inflammation scores were assigned to the stented iliac segments. RESULTS: All stented arteries were angiographically patent. The mean luminal diameter (3.05 mm) and area (30.36 mm2) of DEX-eluting PLA stents were decreased compared to other stents (PLA + P(D,L)LA: 3.66 mm and 43.92 mm2; PLA + SIM: 4.21 mm and 56.48 mm2; PLA + PCL: 4.19 mm and 54.64 mm2; Wallstent: 5.01 mm and 81.19 mm2). Wallstents and DEX-eluting PLA stents induced minimal intimal hyperplasia: PLA + DEX: 0.16 mm, PLA + P(D,L)LA: 0.35 mm, PLA + SIM: 0.33 mm, PLA + PCL: 0.29 mm, and Wallstent: 0.18 mm. The vascular injury scores demonstrated only mild vascular trauma for all stents. Only mild to moderate inflammatory reaction was noted around stent struts with a vascular inflammation score. CONCLUSIONS: Biodegradable polymer stents appear to be biocompatible and reliable, causing minimal neointimal hyperplasia. Furthermore, the new biodegradable poly-D/L-lactic acid stent can be used as a local drug delivery vehicle. The DEX-eluting PLA stent reduces neointimal hyperplasia. The findings show a need for further investigation to prove the efficacy and safety of this new biodegradable drug-eluting stent.

Absorbable Implants↗

Self-reinforced polylactide/polyglycolide 80/20 screws take more than 1(1/2) years to resorb in rabbit cranial bone.

The aim of this study was to assess tissue reactions to bioabsorbable self-reinforced polylactide/polyglycolide (SR-PLGA) 80/20 miniscrews in rabbit cranial bone. One PLGA screw was implanted on one side and one titanium screw on the other side of the sagittal suture (n = 21). Three animals were sacrificed after 2, 4, 8, 16, 24, 54, and 72 weeks. In histological examination the numbers of macrophages, giant cells, active osteoblasts, and fibrous tissue layers were assessed and degradation of the bioabsorbable screws was evaluated. After 2 weeks, macrophages were seen near the heads of both screws. After 4 and 8 weeks, the bioabsorbable screws were surrounded by fibrous tissue. Osteoblastic activity and groups of several giant cells were seen. After 24 weeks, a significant change in the morphology of the PLGA screws had occurred. Osteoblastic activity and the amount of giant cells had decreased. After 1 year, some PLGA biomaterial was still present. PLGA screws had been replaced by adipose tissue, fibrous tissue, and "foamy macrophages" that had PLGA particles inside them. After 1(1/2) years, the amount of biomaterial remaining had decreased remarkably. The particles of biomaterial were inside foamy macrophages. SR-PLGA 80/20 screws are biocompatible and have no clinically manifested complications when used in the cranial bone of rabbits. No contraindications as regards their clinical use in craniofacial surgery was found when these screws were studied in the cranial bones of rabbits.

Animals↗

In vitro and in vivo behavior of self-reinforced bioabsorbable polymer and self-reinforced bioabsorbable polymer/bioactive glass composites.

The aim of this study was to investigate the in vitro and in vivo properties and degradation of (1) self-reinforced (SR) lactide copolymer, P(L/DL)LA 70:30, and (2) SR composites of the same polylactide and bioactive glass 13-93. The following three polymer and polymer-bioactive glass samples were studied: SR-PLA70, SR-PLA70 + BaG15s, and SR-PLA70 + BaG20c. In vitro behavior was studied in a phosphate-buffered saline for 87 weeks at 37 degrees +/- 1 degrees C and a pH of 7.4 +/- 0.2. In vivo behavior was studied by implanting the rods in the dorsal subcutaneous tissue of rats (SR-PLA70 + BaG20c) or rabbits (SR-PLA70 and SR-PLA70 + BaG15s) for 48 weeks. The degradation of the specimens was evaluated by measuring the changes in mechanical properties, crystallinity and molecular weight of polymer, water absorption, weight loss, and structural changes. Results showed that the addition of bioactive glass filler modified the degradation kinetics and material morphology.

Absorbable Implants↗