PubMed Health⌕ Search

Biomedical subjects

Peter Andriessen

Publications and source records attributed to Peter Andriessen.

6 recordsLinked to original sources

Baroreceptor reflex sensitivity in human neonates: the effect of postmenstrual age.

We performed a cross-sectional study in human infants to determine if indices of R-R interval variability, systolic blood pressure (SBP) variability, and baroreceptor reflex sensitivity change with postmenstrual age (PMA: gestational age+postnatal age). The electrocardiogram, arterial SBP and respiration were recorded in clinically stable infants (PMA, 28-42 weeks) in the quiet sleep state in the first days after birth. (Cross-)spectral analyses of R-R interval series and SBP series were performed to calculate the power of low-frequency (LF, indicating baroreceptor reflex activity, 0.04-0.15 Hz) and high-frequency (HF, indicating parasympathetic activity, individualized between the p-10 and p-90 values of respiratory frequency) fluctuations, and transfer function phase and gain. The mean R-R interval, and LF and HF spectral powers of R-R interval series increased with PMA. The mean SBP increased with PMA, but not the LF and HF spectral powers of SBP series. In the LF range, cross-spectral analysis showed high coherence values (>0.5) with a consistent negative phase shift between R-R interval and SBP, indicating a approximately 3 s lag in R-R interval changes in relation to SBP. Baroreceptor reflex sensitivity, calculated from LF transfer gain, increased significantly with PMA, from 5 (preterm) to 15 ms mmHg-1 (term). Baroreceptor reflex sensitivity correlated significantly with the (LF and) HF spectral powers of R-R interval series, but not with the LF and HF spectral powers of SBP series. The principal conclusions are that baroreceptor reflex sensitivity and spectral power in R-R interval series increase in parallel with PMA, suggesting a progressive vagal maturation with PMA.

Baroreflex↗

Cardiovascular autonomic regulation in preterm infants: the effect of atropine.

To study cardiovascular autonomic control, we assessed the effect of atropine on heart rate (HR) and blood pressure (BP) variability in 12 preterm infants (range 26-32 wk) before intubation for respiratory insufficiency. Spectral power analysis of R-R interval and systolic BP (SBP) series were estimated in a low-frequency (LF; 0.04-0.15 Hz) and high-frequency (HF; 0.4-1.5 Hz) band and evaluated for a 10-min period before and a 10-min period after atropine sulfate (0.01 mg/kg). Baroreceptor reflex (BR) functioning was estimated using transfer function analysis at LF (coherence, gain, and phase). Atropine resulted in a significant 12% increase in steady-state HR (p < 0.01) and unchanged SBP. For R-R interval series, the total spectral power decreased 6-fold (p < 0.01), which was predominantly due to a reduction in the LF band (16-fold; p < 0.01). In contrast, we observed a significant increase (25%; p < 0.05) in total spectral power of SBP series partly as a result of an increase in HF power. The LF power of SBP series was not altered. The median LF transfer gain (BR sensitivity) between SBP and R-R interval decreased from 4.2 to 1.4 ms/mm Hg (p < 0.01) after atropine. The LF phase relationship (BP leads R-R interval fluctuations by approximately 4 s) was not changed after atropine. In conclusion, even in preterm infants in distress, atropine modulates HR and BP variability, suggesting that BR-mediated parasympathetic control of heart rate is of significance for cardiovascular control at that age.

Atropine↗

Beat-to-beat detection of fetal heart rate: Doppler ultrasound cardiotocography compared to direct ECG cardiotocography in time and frequency domain.

In order to obtain power spectral information on the fetal heart rate in stages of pregnancy earlier than labor an algorithm has been developed to calculate the fetal heart rate on a beat-to-beat basis from Doppler ultrasound cardiotocographic signals. The algorithm was evaluated by comparing the calculated fetal heart rate with the heart rate determined from direct ECG signals measured with a scalp electrode. Heart rates were compared both in time and frequency domain. In the time domain the results achieved by both methods correlate well (correlation coefficient = 0.977 (p < 0.001)), in the frequency domain the results correlate even better (correlation coefficient = 0.991 (p < 0.001)). Based on these findings, it can be concluded that the developed algorithm provides a valuable tool for obtaining power spectral information on the fetal heart rate in stages of pregnancy earlier than labor.

Cardiotocography↗

Noninvasive assessment of blood pressure variability in preterm infants.

The feasibility of measuring blood pressure (BP) variability by a noninvasive beat-to-beat finger arterial BP device (Finapres) was assessed in preterm infants. By application of the finger cuff around the infant's wrist, time and frequency domain (spectral power) analysis of noninvasive beat-to-beat BP signals were compared with intra-arterial measurements. A fast Fourier Transform was used to compute the spectral power density from 128-s periods. The low-frequency band (LF; 0.04-0.15 Hz) is partly associated with baroreflex activity. The high-frequency band (HF; 0.4-1.5 Hz) is associated with respiratory activity. In eight subjects above 1000 g, reliable signals could be obtained. We observed a high correlation between noninvasive and intra-arterial beat-to-beat systolic BP values (mean r value +/- SD, 0.87 +/- 0.11), with a gain close to 1 (mean gain +/- SD, 1.0 +/- 0.4 mm Hg/mm Hg). Finapres estimated beat-to-beat systolic BP changes more accurately than diastolic values. We found a very high amount of linear coupling, expressed as coherence function, between the power spectra of noninvasive and intra-arterial systolic BP measurements. For systolic BP, the (pooled) group mean +/- SEM coherence values were 0.93 +/- 0.00 and 0.91 +/- 0.01 for LF and HF fluctuations, respectively (NS). The wrist method of Finapres in neonates has limited value in estimating absolute BP but is useful in a clinical research situation, where identification of beat-to-beat changes in systolic BP is more important. Finapres provides a noninvasive tool for investigating autonomic cardiovascular regulation (baroreflex sensitivity, spectral analysis of BP fluctuations) in neonates.

Baroreflex↗

Cardiovascular fluctuations and transfer function analysis in stable preterm infants.

To examine the baroreceptor reflex function, a beat-to-beat analysis between systolic blood pressure (SBP) and R-R interval fluctuations was studied in 10 stable appropriate-for-gestational age preterm infants (range, 27.2-33.7 wk) in the first postnatal week during quiet sleep. Spectral power analysis, using fast Fourier transform, and transfer functions (gain and phase difference) between SBP and R-R fluctuations were estimated in a low-frequency band (LF, 0.03-0.2 Hz) and high-frequency band (HF defined as the frequency band between the 10th and 90th centiles of the individual respiratory frequency). The LF/HF ratio reflects the sympathovagal balance. The mean frequency (+/-SD) of LF peaks was centered at 0.07 +/- 0.02 Hz. The mean frequency (+/-SD) of the individual HF band was 0.82 +/- 0.21 Hz. The LF/HF ratio in the R-R interval series [median, 29; interquartile range (IQR), 16-40] was higher than in the SBP series (median, 8; IQR, 4-14). The gain between R-R interval and SBP fluctuations (median, 4.2 ms/mm Hg; IQR, 2.4-5.0) in the LF band was higher than in the HF band (median, 1.7 ms/mm Hg; IQR, 1.4-3.0). SBP fluctuations lead R-R interval fluctuations in the LF band with a median phase difference of +96 degrees (IQR, 67-132). At LF the fluctuations in SBP precede changes in R-R interval with a time delay of 3.8 s. These observations indicate a dominant role of the sympathetic system in stable preterm infants in comparison with published adult values. Cross-spectral analysis allows a test for tracking the development of the sympathetic system in neonates.

Cardiovascular Physiological Phenomena↗