PubMed Health⌕ Search

Biomedical subjects

Peter B Brown

Publications and source records attributed to Peter B Brown.

4 recordsLinked to original sources

Sample-specific diamagnetic and paramagnetic passive shimming.

When homogenizing the static magnetic field over extended in vivo volumes, significant residual inhomogeneity can remain after spherical harmonic shim optimization. This is due to the low spatial orders of shims available on in vivo MR systems and the presence of higher-order inhomogeneity in the vicinity of anatomic air cavities. Mediation of this problem through the development of higher-order spherical harmonic shims is severely impeded by bore space limitations. Sample-specific passive shims are not limited to low-order spatial compensation and offer an alternative means to increased homogenization. Here, we present a novel construction protocol for sample-specific passive shims comprised of both diamagnetic (bismuth) and paramagnetic (zirconium) materials. A prototype shim is constructed and shown to significantly homogenize the mouse brain at 9.4 T. Further homogenization capabilities are simulated through alteration of the shim construction.

Animals↗

High magnetic field water and metabolite proton T1 and T2 relaxation in rat brain in vivo.

Comprehensive and quantitative measurements of T1 and T2 relaxation times of water, metabolites, and macromolecules in rat brain under similar experimental conditions at three high magnetic field strengths (4.0 T, 9.4 T, and 11.7 T) are presented. Water relaxation showed a highly significant increase (T1) and decrease (T2) with increasing field strength for all nine analyzed brain structures. Similar but less pronounced effects were observed for all metabolites. Macromolecules displayed field-independent T2 relaxation and a strong increase of T1 with field strength. Among other features, these data show that while spectral resolution continues to increase with field strength, the absolute signal-to-noise ratio (SNR) in T1/T2-based anatomical MRI quickly levels off beyond approximately 7 T and may actually decrease at higher magnetic fields.

Animals↗

Detection of [1,6-13C2]-glucose metabolism in rat brain by in vivo 1H-[13C]-NMR spectroscopy.

Localized, water-suppressed (1)H-[(13)C]-NMR spectroscopy was used to detect (13)C-label accumulation in cerebral metabolites following the intravenous infusion of [1,6-(13)C(2)]-glucose (Glc). The (1)H-[(13)C]-NMR method, based on adiabatic RF pulses, 3D image-selected in vivo spectroscopy (ISIS) localization, and optimal shimming, yielded high-quality (1)H-[(13)C]-NMR spectra with optimal NMR sensitivity. As a result, the (13)C labeling of [4-(13)C]-glutamate (Glu) and [4-(13)C]-glutamine (Gln) could be detected from relatively small volumes (100 microL) with a high temporal resolution. The formation of [n-(13)C]-Glu, [n-(13)C]-Gln (n = 2 or 3), [2-(13)C]-aspartate (Asp), [3-(13)C]-Asp, [3-(13)C]-alanine (Ala), and [3-(13)C]-lactate (Lac) was also observed to be reproducible. The (13)C-label incorporation curves of [4-(13)C]-Glu and [4-(13)C]-Gln provided direct information on metabolic pathways. Using a two-compartment metabolic model, the tricarboxylic acid (TCA) cycle flux was determined as 0.52 +/- 0.04 micromol/min/g, while the glutamatergic neurotransmitter flux equaled 0.25 +/- 0.05 micromol/min/g, in good correspondence with previously determined values.

Animals↗

Dynamic shim updating (DSU) for multislice signal acquisition.

Dynamic shim updating (DSU) is a technique for achieving optimal magnetic field homogeneity over extended volumes by dynamically updating an optimal shim setting for each individual slice in a multislice acquisition protocol. Here the practical implementation of DSU using all first- and second-order shims is described. In particular, the hardware modifications and software requirements are demonstrated. Furthermore, the temporal effects of dynamically switching shim currents are investigated and a Z(2)-to-Z(0) compensation unit is described and implemented to counteract the temporal Z(0) variations following a change in the Z(2) shim current. The optimal shim settings for all slices are determined with a quantitative and user-independent, multislice phase-mapping sequence. The performance of DSU is evaluated from multislice phase maps and spectroscopic images acquired on rat brain in vivo. DSU improved the magnetic field homogeneity over all spatial slices, with a more pronounced effect on the slices positioned away from the magnet isocenter, thereby making the magnetic field homogeneity highly uniform over an extended volume.

Animals↗