Image-based tracking of optically detunable parallel resonant circuits.

In this work strategies for the robust localization of parallel resonant circuits are investigated. These strategies are based on the subtraction of two images, which ideally differ in signal intensity at the positions of the devices only. To modulate their signal amplification, and thereby generate the local variations, the parallel resonant circuits are alternately detuned and retuned during the acquisition. The integration of photodiodes into the devices permits their fast optical switching. Radial and spiral imaging sequences are modified to provide the data for the two images in addition to those for a conventional image in the same acquisition time. The strategies were evaluated by phantom experiments with stationary and moving catheter-borne devices. In particular, rapid detuning and retuning during the sampling of single profiles is shown to lead to a robust localization. Moreover, this strategy eliminates most of the drawbacks usually associated with image-based tracking, such as low temporal resolution. Image-based tracking may thus become a competitive (if not superior) alternative to projection-based tracking of parallel resonant circuits.

Catheterization↗

Combined high-resolution and real-time imaging: a technical feasibility study on coronary magnetic resonance angiography.

PURPOSE: To propose a new approach to combining high-resolution and real-time imaging and to show its technical feasibility on the example of coronary magnetic resonance angiography. MATERIALS AND METHODS: The insertion of fast two-dimensional (2D) acquisitions into time intervals that have not been utilized by triggered or gated 2D or three-dimensional (3D) acquisitions so far is suggested, as well as the immediate reconstruction and display of the additional data. For a technical validation of this concept, a 2D ventricular function protocol was interleaved into a cardiac-triggered and respiratory-gated 3D coronary angiography protocol. Dedicated hardware was employed to rapidly process the data originating from the former. Since the sampling of the latter was restricted to intervals with minimal motion, remaining periods of time could be used to simultaneously image the cardiac and respiratory motion. RESULTS: The technical feasibility of the proposed approach was demonstrated by successful measurements with the combined high-resolution and real-time protocol in volunteers. All examinations provided short axis views during the acquisition and angiograms of selected parts of the coronary system after its completion. CONCLUSION: The investigated concept allows high-resolution measurements to be complemented with real-time imaging functionality without affecting the scan time or image quality. In the particular application considered, an image-based patient monitoring or motion correction is enabled, indicating potential benefits of combining two very dissimilar methods of data acquisition in one measurement.

Coronary Circulation↗