PubMed Health⌕ Search

Biomedical subjects

Peter D Gatehouse

Publications and source records attributed to Peter D Gatehouse.

28 records · Page 2Linked to original sources

Combined long- and short-axis myocardial perfusion cardiovascular magnetic resonance.

PURPOSE: To date, myocardial perfusion cardiovascular magnetic resonance (CMR) has been reported in single and multiple short-axis slices. Three short-axis planes can assess 16 segments of the standard 17-segment myocardial model, but this approach fails to assess the ventricular apex that requires at least one long-axis plane. We therefore evaluated the feasibility and benefit of combined long- and short-axis perfusion CMR to enable complete 17 segments coverage for comprehensive myocardial perfusion assessment. METHODS AND MATERIALS: Using a hybrid echo planar imaging (EPI) sequence, we performed rest and adenosine stress first-pass perfusion CMR studies with 3 short-axis (basal, mid, apical) planes, and additional long-axis planes in the same cardiac cycle in a broad range of cardiology patients. RESULTS: Perfusion CMR was performed in 53 consecutive patients using the combined short-long-axis imaging protocol. Twenty-nine of those studied had known or suspected coronary artery disease (CAD), 18 hypertrophic cardiomyopathy, and 6 suspected microvascular perfusion abnormalities. In 39 patients (70%), it was possible to acquire 5 slices at rest and stress including both the horizontal and vertical long axes. In 15 patients (27%), only one long-axis could be acquired, and in 2 patients (5%) only 3 slices (short axis) could be obtained. However, in none of the patients with known or suspected CAD was apical ischemia demonstrated by the long-axis views, despite apical ischemia having been demonstrated with recent SPECT studies in 8 of these patients. CONCLUSION: Rest-stress myocardial perfusion CMR is able to achieve complete segmental coverage of the myocardium using the combined short-long axis approach using an EPI sequence in 97% of a long series of consecutive cardiology patients, while maintaining excellent spatial resolution. However, the long-axis views were not found to be able to demonstrate inducible perfusion defects in the apex.

Adult↗

A single breath-hold multiecho T2* cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload.

PURPOSE: To assess tissue iron concentrations by the use of a gradient echo T2* multiecho technique. MATERIALS AND METHODS: We compared the results of measurements of heart T2* from 32 patients using the established multiple breath-hold variable TR technique with a new multiecho sequence that acquires all images within a single breath-hold with constant TR. RESULTS: There was good agreement of myocardial T2* values between both methods in the abnormal range of T2* < 20 msec (mean difference 0.2 msec, 95% CI -1.3 to 0.9 msec, r = 0.97, P < 0.0001). The coefficient of variability between the methods was 3.5%. The interstudy reproducibility using the multiecho sequence had a variability coefficient of 2.3% in the abnormal T2* range and 5.8% over all T2* values. There was good agreement between the techniques for the liver T2* values. CONCLUSIONS: The use of the single breath-hold, multiecho acquisition allowed reliable quantification of myocardial T2*. The good reproducibility, speed, and T1 independence of this technique allows greater accuracy, faster patient throughput, and, therefore, reduced costs (which is important in developing countries where thalassemia is most prevalent).

Adolescent↗

Breath-hold signal-loss sequence for the qualitative assessment of flow disturbances in cardiovascular MR.

PURPOSE: To develop a breath-hold segmented sequence which generates similar patterns of signal loss to a non-breath-hold, relatively long echo time, conventional gradient echo sequence for the qualitative assessment of valvular heart disease. MATERIALS AND METHODS: Both velocity-sensitized and acceleration-sensitized segmented sequences were developed. The sensitivities were empirically adjusted to give similar degrees of signal loss to a conventional sequence. These sequences were compared with a conventional sequence in eight patients with flow disturbances and in four healthy subjects. RESULTS: There was no significant difference in the extent of signal loss observed when using the breath-hold velocity- and acceleration-sensitized sequences developed and the conventional sequence (1862 mm(2), 1831 mm(2), and 1782 mm(2), respectively; P = ns). However, the image quality obtained was significantly better with the breath-hold sequences (both P < 0.01). Furthermore, the image quality achieved with the acceleration-sensitized sequence was significantly better than that achieved with the velocity-sensitized sequence (P < 0.01) where artifacts from beat-to-beat variations in blood-flow velocities were a frequent problem. CONCLUSION: Signal loss in complex flow is best demonstrated using the breath-hold acceleration-sensitized sequence where the signal from both stationary and constant velocity material is rephased at the echo time.

Adult↗

Interscanner reproducibility of cardiovascular magnetic resonance T2* measurements of tissue iron in thalassemia.

PURPOSE: To assess interscanner reproducibility of tissue iron measurements in patients with thalassemia using gradient echo T2* measurements on two different MRI scanners. MATERIALS AND METHODS: Twenty-five patients with thalassemia major had liver and myocardial T2* assessment using a Picker Edge 1.5T Scanner and a Siemens Sonata 1.5T scanner, with similar gradient echo sequences. In a subset of 13 patients, two scans on the Siemens scanner were performed to assess interstudy reproducibility. RESULTS: There was a highly significant, linear correlation between T2* values obtained for both the heart (r = 0.95) and the liver (r = 0.99) between scanners. The mean difference, coefficient of variability, and 95% confidence intervals between scanners were 0.8 msec, 9.4% and -5.0 to 6.7 msec for the heart; and 0.9 msec, 7.9% and -2.0 to 3.9 msec for the liver. The interstudy mean difference and coefficient of variability on the Siemens scanner was 0.3 msec and 4.8% (r = 0.99) for the heart, and 0.04 msec and 1.9% (r = 0.99) for the liver. CONCLUSION: The T2* technique for measuring tissue iron is reproducible between the two manufacturers' scanners. This suggests that the widespread implementation of the technique is possible for clinical assessment of myocardial iron loading in thalassemia.

Adult↗

Magnetic resonance imaging of the liver with ultrashort TE (UTE) pulse sequences.

PURPOSE: To assess the feasibility of imaging the liver in volunteers and patients with ultrashort echo time (UTE) pulse sequences. MATERIALS AND METHODS: Seven normal controls as well as 12 patients with biopsy-proven generalized liver disease and three patients with focal disease were examined using pulse sequences with initial TEs of 0.08 msec followed by three later echoes, with or without frequency-based fat suppression. T(2)* values were calculated from regions of interest in the liver. RESULTS: Good image quality was obtained in each subject. There was a highly significant difference in the mean T(2)* values between the normal controls and patients with generalized liver disease (P = 0.001). T(2)* was significantly decreased in hemochromatosis (P = 0.002) and increased in cirrhosis (P = 0.04), compared with controls. T(2)* also correlated with functional status assessed by Child's grade (P = 0.001). A hepatocellular carcinoma showed reduced short T(2) components in the region of thermal ablation and evidence of a subcapsular hematoma which were not apparent with conventional imaging. CONCLUSIONS: Imaging of the liver with UTE sequences showed good image quality and tolerance of abdominal motion. T(2)* was specifically correlated with the presence of hemochromatosis, cirrhosis, and functional grade. Imaging of short T(2) relaxation components may provide useful information in disease.

Adult↗

Progress towards patient-specific computational flow modeling of the left heart via combination of magnetic resonance imaging with computational fluid dynamics.

A combined computational fluid dynamics (CFD) and magnetic resonance imaging (MRI) methodology has been developed to simulate blood flow in a subject-specific left heart. The research continues from earlier experience in modeling the human left ventricle using time-varying anatomical MR scans. Breathing artifacts are reduced by means of a MR navigator echo sequence with feedback to the subject, allowing a near constant breath-hold diaphragm position. An improved interactive segmentation technique for the long- and short-axis anatomical slices is used. The computational domain is extended to include the proximal left atrium and ascending aorta as well as the left ventricle, and the mitral and aortic valve orifices are approximately represented. The CFD results show remarkable correspondence with the MR velocity data acquired for comparison purposes, as well as with previously published in vivo experiments (velocity and pressure). Coherent vortex formation is observed below the mitral valve, with a larger anterior vortex dominating the late-diastolic phases. Some quantitative discrepancies exist between the CFD and MRI flow velocities, owing to the limitations of the MR dataset in the valve region, heart rate differences in the anatomical and velocity acquisitions, and to certain phenomena that were not simulated. The CFD results compare well with measured ranges in literature.

Adult↗

Long-term use of contraceptive depot medroxyprogesterone acetate in young women impairs arterial endothelial function assessed by cardiovascular magnetic resonance.

BACKGROUND: Depot medroxyprogesterone acetate (DMPA) inhibits proliferation of ovarian follicles, resulting in anovulation and a decrease in circulating estrogen; the latter action is potentially disadvantageous to cardiovascular health. We therefore investigated the vascular effects of long-term contraceptive DMPA in young women. METHODS AND RESULTS: Endothelium-dependent (hyperemia-induced flow-mediated dilatation [FMD]) and -independent (glyceryl trinitrate [GTN]) changes in brachial artery area were measured using cardiovascular magnetic resonance in 13 amenorrheic DMPA users (>1 year use; mean age 29+/-4 years) and in 10 controls (mean age 30+/-4 years, P=0.25) with regular menstrual cycles after validation of the technique. FMD and GTN responses were measured just before repeat MPA injection and 48 hours later (n=12) in DMPA users and during menstruation and midcycle (n=9) in controls. Serum-estradiol levels (S-estradiol) were measured at both visits. FMD was reduced in DMPA users compared with controls during menstruation (1.1% versus 8.0%, respectively P<0.01) without differences in GTN responses. S-estradiol levels in DMPA users were significantly lower than in controls during menstruation (58 versus 96 pmol/L, P<0.01). High levels of circulating MPA 48 hours after injection were not linked to an additional impairment in FMD (2.0% versus 3.1%, P=0.23). Estradiol levels were significantly correlated to FMD (r=0.43, P<0.01). CONCLUSIONS: Endothelium-dependent arterial function measured by cardiovascular magnetic resonance is impaired in chronic users of DMPA, and hypoestrogenism may be the mechanism of action. DMPA might adversely affect cardiovascular health, and in particular its use in women with cardiovascular disease should be additionally evaluated.

Adult↗

Abnormal subendocardial perfusion in cardiac syndrome X detected by cardiovascular magnetic resonance imaging.

BACKGROUND: In cardiac syndrome X (a syndrome characterized by typical angina, abnormal exercise-test results, and normal coronary arteries), conventional investigations have not found that chest pain is due to myocardial ischemia. Magnetic resonance techniques have higher resolution and therefore may be more sensitive. METHODS: We performed myocardial-perfusion cardiovascular magnetic resonance imaging in 20 patients with syndrome X and 10 matched controls, both at rest and during an infusion of adenosine. Quantitative perfusion analysis was performed by using the normalized upslope of myocardial signal enhancement to derive the myocardial perfusion index and the myocardial-perfusion reserve index (defined as the ratio of the myocardial perfusion index during stress to the index at rest). RESULTS: In the controls, the myocardial perfusion index increased in both myocardial layers with adenosine (in the subendocardium, from a mean [+/-SD] of 0.12+/-0.03 to 0.16+/-0.03 [P=0.02]; in the subepicardium, from 0.11+/-0.02 to 0.17+/-0.05 [P=0.002]); in patients with syndrome X, the myocardial perfusion index did not change significantly in the subendocardium (0.13+/-0.02 vs. 0.14+/-0.03, P=0.11; P=0.09 as compared with controls) but increased in the subepicardium (from 0.11+/-0.02 to 0.20+/-0.04, P<0.001; P=0.11 for the comparison with controls). Adenosine provoked chest pain in 95 percent of patients with syndrome X and 40 percent of controls (P<0.001). CONCLUSIONS: In patients with syndrome X, cardiovascular magnetic resonance imaging demonstrates subendocardial hypoperfusion during the intravenous administration of adenosine, which is associated with intense chest pain. These data support the notion that the chest pain may have an ischemic cause.

Adenosine↗

Initial experience with the intravascular contrast agent NC100150-injection (Clariscan) for breath-hold and navigator-gated magnetic resonance coronary artery imaging.

PURPOSE: To examine magnetic resonance coronary artery imaging after NC100150-Injection. MATERIALS AND METHODS: Breath-hold and navigator-gated images were acquired in five patients. RESULTS: Breath-hold image quality, coronary artery-fat SDNR, and coronary artery SNR improved. Respiratory artifacts due to reduced liver signal intensity degraded navigator-gated image quality. CONCLUSION: NC100150-Injection improves breath-hold coronary artery imaging. Navigator-gated acquisitions should use techniques that are insensitive to T2* effects.

Aged↗

Magnetic resonance: an introduction to ultrashort TE (UTE) imaging.

The background underpinning the clinical use of ultrashort echo-time (UTE) pulse sequences for imaging tissues or tissue components with short T2s is reviewed. Tissues properties are discussed, and tissues are divided into those with a majority of short T2 relaxation components and those with a minority. Features of the basic physics relevant to UTE imaging are described including the fact that when the radiofrequency pulse duration is of the order T2, rotation of tissue magnetization into the transverse plane is incomplete. Consequences of the broad line-width of short T2 components are also discussed including their partial saturation by off-resonance fat suppression pulses as well as multislice and multiecho imaging. The need for rapid data acquisition of the order T2 is explained. The basic UTE pulse sequence with its half excitation pulse and radial imaging from the center of k-space is described together with options that suppress fat and/or long T2 components. Image interpretation is discussed. Clinical features of the imaging of cortical bone, tendons, ligaments, menisci, and periosteum as well as brain, liver, and spine are illustrated. Short T2 components in all of these tissues may show high signals. Possible future developments are outlined as are technical limitations.

Humans↗