PubMed Health⌕ Search

Biomedical subjects

Peter DePhillips

Publications and source records attributed to Peter DePhillips.

4 recordsLinked to original sources

5-Dodecanoylaminofluorescein as a probe for the determination of critical micelle concentration of detergents using fluorescence anisotropy.

A method for determining the critical micelle concentration (CMC) of various detergents based on fluorescence polarization (anisotropy) of the lipophilic probe 5-dodecanoylaminofluorescein is presented. Nonionic, cationic, anionic, and steroid-based detergents can all be evaluated by this method and the determined CMC values of selected detergents agree well with those reported in the literature. In addition, we report the CMC of domiphen bromide, whose CMC value has not previously been described. In the case of ionic detergents, the method described is particularly sensitive at discerning changes in the CMC with increasing ionic strength of the medium and can discriminate detergent CMCs in 5 mM versus 25 mM buffering components. The described fluorescence polarization technique allows very low (submicromolar) concentrations of probe to be employed, thus minimizing the perturbation of micelle formation by 5-dodecanoylaminofluorescein insertion.

Detergents↗

An automated homogeneous method for quantifying polysorbate using fluorescence polarization.

An automated fluorescence polarization (FP) assay has been developed for the quantitation of polysorbate in bioprocess samples. Using the lipophilic probe 5-dodecanoylaminofluorescein (DAF), polysorbate concentrations above the critical micelle concentration can be quantified by the FP increase that results when DAF inserts into the detergent micelles. The specificity, accuracy, and precision of this assay were defined for samples obtained from vaccine purification processes. Spike recoveries were 98-106% for purified products and 110-120% for crude process intermediates. The coefficients of variation for intra- and interassay precision were less than 9 and 14%, respectively. Because of the operational simplicity of the assay, all of the assay steps from sample preparation to data reduction were automated on a Tecan liquid-handling workstation. The combination of a rapid assay and an automated format makes this method well suited to the routine analysis of samples from trial purification processes which are carried out during the development of a vaccine or therapeutic protein. This method should be adaptable for the quantitation of other detergents into which DAF will insert.

Automation↗

Effect of spacer arm length on protein retention on a strong cation exchange adsorbent.

The retention of five proteins was compared on a set of three strong cation exchange adsorbents that differed in spacer arm chemical structure and length. The adsorbents included a commercial product, Amersham Biosciences SP Sepharose Fast Flow, containing a six-carbon spacer between the agarose matrix and the anionic ligand, and two custom-prepared materials. One of the custom adsorbents contained a spacer of about half the length of the SP Sepharose Fast Flow, and the other contained no spacer arm. The adsorbent with no spacer arm was found to be significantly more retentive for all of the test proteins examined, in both isocratic and gradient elution tests. Reducing the spacer arm length by half resulted in increased retention for four of the five proteins, but this increase was less than what was observed when the spacer arm was eliminated. Retention increases were obtained without increasing the density of the anionic charge groups and appear to result from an enhancement of electrostatic or secondary nonelectrostatic interactions, or both. The results indicate that spacer arm length may be a useful variable in manipulating stationary-phase retention properties.

Adsorption↗

Relative retention of the fibroblast growth factors FGF-1 and FGF-2 on strong cation-exchange sorbents.

The isocratic retention of two heparin-binding fibroblast growth factors, FGF-1 (acidic FGF) and FGF-2 (basic FGF), was compared on a set of six preparative strong cation-exchange adsorbents. The FGFs comprise a solute pair that are structurally equivalent, yet differ in protein parameters of potential importance in cation-exchange chromatography, such as isoelectric point, net charge, and the number and distribution of basic amino acids. The cation-exchange adsorbents comprise a diverse set of materials in common use for protein purification, with physical and chemical properties that have been characterized and described previously. Isocratic k' values for the two proteins obtained on each adsorbent at several different [NaCl] are compared with one another and with corresponding data for hen egg lysozyme, which is also strongly retained on cation-exchangers. Of the six adsorbents examined, three showed strong retention of both FGFs, with equivalent k' values for FGF-1 and FGF-2. Three others, which showed weaker overall retention for the FGF pair, showed much larger retention differences between FGF-1 and FGF-2. The trends in retention order among the stationary phases are very similar to those seen previously with other unrelated proteins. However, retention differences between the two FGFs, and between the FGFs and lysozyme, do not correlate well with simple charge properties such as net charge, indicating, as in some previous studies, the importance of local regions on the protein surface in determining retention. These observations are interpreted in terms of the structural features of the proteins and the physicochemical properties of the adsorbents.

Adsorption↗