PubMed Health⌕ Search

Biomedical subjects

Peter Fox

Publications and source records attributed to Peter Fox.

13 recordsLinked to original sources

Unique, common, and interacting cortical correlates of thirst and pain.

This study used positron-emission tomography to establish the patterns of brain activity involved in the isolated and concurrent experiences of thirst and pain. Ten subjects were scanned while experiencing pain evoked with noxious pressure, while experiencing thirst after the infusion of hypertonic saline, and while experiencing pain when thirsty. After the onset of thirst, noxious pressure evoked more intense sensations of pain. Noxious pressure did not change subjective ratings of thirst. Thirst caused activation in the anterior cingulate (Brodmann area 32) and the insula. Enhanced pain responses were associated with increased activity in cortical regions that are known to correlate with pain intensity, and also with unique activity in the pregenual anterior cingulate and ventral orbitofrontal cortex. These findings suggest a role for limbic and prefrontal cortices in the modulation of pain during the experience of thirst.

Adult↗

Retrospective motion correction protocol for high-resolution anatomical MRI.

Modern computational brain morphology methods require that anatomical images be acquired at high resolution and with a high signal-to-noise ratio. This often translates into long acquisition times (>20 minutes) and images susceptible to head motion. In this study we tested retrospective motion correction (RMC), common for functional MRI (fMRI) and PET image motion correction, as a means to improve the quality of high-resolution 3-D anatomical MR images. RMC methods are known to be effective for correcting interscan motion; therefore, a single high-resolution 3-D MRI brain study was divided into six shorter acquisition segments to help shift intrascan motion into interscan motion. To help reduce intrascan head motion, each segment image was reviewed for motion artifacts and repeated if necessary. Interscan motion correction was done by spatially registering images to the third image and forming a single average motion-corrected image. RMC was tested on 35 subjects who were considered at high risk for head motion. Our results show that RMC provided better contrast-to-noise ratio and boundary detail when compared to nonmotion-corrected averaged images.

Adolescent↗

Transformation of molecular weight distributions of dissolved organic carbon and UV-absorbing compounds at full-scale wastewater-treatment plants.

The molecular-weight distribution (MWD) of wastewater dissolved-organic carbon (DOC) was determined in samples from seven full-scale wastewater-treatment plants (WWTPs) that use different biological treatments (air activated sludge [air-AS], pure-oxygen AS [O2-AS], and trickling filters). The research objective was to determine how different biological treatments influenced the MWD of wastewater DOC. Primary sedimentation effluent DOC from most of the WWTPs exhibited a skewed distribution toward the low-molecular-weight fraction (MWF) (40 to 50%, < 0.5 K Daltons [KDa]). The Air-AS effluent DOC exhibited a centrally clustered distribution, with the majority of DOC in the intermediate MWF (0.5 to 3 KDa). The O2-AS effluent DOC exhibited a skewed distribution toward the high MWF (> 3 KDa). The removal of DOC by air- and O2-AS bacteria followed trends predicted by a macromolecule degradation model. Trickling-filter effluent DOC exhibited a skewed distribution toward the high MWF (50% DOC, > 3 KDa).

Biodegradation, Environmental↗

Comparison of dissolved-organic-carbon residuals from air- and pure-oxygen-activated-sludge sequencing-batch reactors.

Literature shows that full-scale pure-oxygen activated sludge (O2-AS) wastewater treatment plants (WWTPs) generate effluents with higher dissolved-organic carbon (DOC) concentrations and larger high-molecular-weight fractions compared to air-activated-sludge (Air-AS) WWTP effluents. The purpose of this paper was to evaluate how gas supplied (air vs. pure oxygen) to sequencing-batch reactors affected DOC transformations. The main conclusions of this paper are (a) O2-AS effluent DOC is more refractory than air-AS effluent DOC; and (b) O2-AS systems may have higher five-day biochemical oxygen demand removals than air-AS systems; however, in terms of COD and DOC removal, air-AS systems are better than O2-AS systems. Analysis of a database from side-by-side O2- and air-AS pilot tests from literature supported these observations.

Air↗

Structural brain changes in bipolar disorder using deformation field morphometry.

The objective of this study was to investigate anatomical brain abnormalities in adult bipolar patients using a deformation field morphometry technique. Our sample consisted of 32 right-handed bipolar I patients (men/women=16/16) and 32 right-handed, age and gender matched healthy controls. Deformation field morphometry analysis was performed on three-dimensional spoiled gradient recalled acquisition images. We found gender-specific structural differences between bipolar patients and healthy individuals. Bipolar men had significantly larger lateral ventricles (especially pronounced in the left hemisphere) and smaller left dorsolateral prefrontal cortex than healthy male controls. Our results are complementary to the findings of functional imaging and post-mortem studies that demonstrate abnormalities in the dorsolateral prefrontal cortex in bipolar patients.

Adolescent↗

Evaluation of an image-guided, robotically positioned transcranial magnetic stimulation system.

The emergence of transcranial magnetic stimulation (TMS) as a tool for investigating the brain has been remarkable over the past decade. While many centers are now using TMS, little has been done to automate the delivery of planned TMS stimulation for research and/or clinical use. We report on an image-guided robotically positioned TMS system (irTMS) developed for this purpose. Stimulation sites are selected from functional images overlaid onto anatomical MR images, and the system calculates a treatment plan and robotically positions the TMS coil following that plan. A new theory, stating that cortical response to TMS is highest when the induced E-field is oriented parallel to cortical columns, is used by the irTMS system for planning the position and orientation of the TMS coil. This automated approach to TMS planning and delivery provides a consistent and optimized method for TMS stimulation of cortical regions of the brain. We evaluated the positional accuracy and utility of the irTMS system with a B-shaped TMS coil. Treatment plans were evaluated for sites widely distributed about a head phantom with well-defined landmarks. The overall accuracy in positioning the planned site of the TMS coil was approximately 2 mm, similar to that reported for the robot alone. The estimated maximum range of error in planned vs. delivered E-field strength was +4%, suggesting a high degree of accuracy and reproducibility in the planned use of the irTMS system.

Brain↗

Neural correlates of the emergence of consciousness of thirst.

Thirst was induced by rapid i.v. infusion of hypertonic saline (0.51 M at 13.4 ml/min). Ten humans were neuroimaged by positron-emission tomography (PET) and four by functional MRI (fMRI). PET images were made 25 min after beginning infusion, when the sensation of thirst began to enter the stream of consciousness. The fMRI images were made when the maximum rate of increase of thirst occurred. The PET results showed regional cerebral blood flow changes similar to those delineated when thirst was maximal. These loci involved the phylogenetically ancient areas of the brain. fMRI showed activation in the anterior wall of the third ventricle, an area that is key in the genesis of thirst but is not an area revealed by PET imaging. Thus, this region plays as major a role in thirst for humans as for animals. Strong activations in the brain with fMRI included the anterior cingulate, parahippocampal gyrus, inferior and middle frontal gyri, insula, and cerebellum. When the subjects drank water to satiation, thirst declined immediately to baseline. A precipitate decline in intensity of activation signal occurred in the anterior cingulate area (Brodmann area 32) putatively related to consciousness of thirst. The intensity of activation in the anterior wall of the third ventricle was essentially unchanged, which is consistent with the fact that a significant time (15-20 min) would be needed before plasma Na concentration changed as a result of water absorption from the gut.

Adult↗

Comparing microfiltration-reverse osmosis and soil-aquifer treatment for indirect potable reuse of water.

Microfiltration (MF) followed by reverse osmosis (RO) and soil-aquifer treatment (SAT) are the two principal technologies considered for indirect potable reuse of wastewater. This study, conducted at the Northwest Water Reclamation Plant, Mesa (Arizona), evaluated MF/RO and SAT (>6 months residence time) treated tertiary effluent with respect to organics removal. Effluent organic matter was characterized as total organic carbon (TOC), by UV absorbance (UVA), solid-state carbon-13 nuclear magnetic resonance spectroscopy, and size exclusion chromatography. Several trace organic micropollutants, including EDTA, NTA, and alkylphenolethoxylate residues, were analyzed by GC/MS. The study revealed that final TOC concentrations of MF/RO and SAT are 0.3 and 1.0 mgl(-1), respectively. Based on the characterization techniques used, the character of bulk organics present in final SAT water resembles the character of natural organic matter present in drinking water. Depending on the molecular weight cut-off, RO membranes can efficiently reject high molecular weight organic matter (characterized as humic and fulvic acids). However, approximately 40-50 percent of the remaining TOC in permeates consists of low molecular weight acids and neutrals representing a molecular weight range of approximately 500Da and less. In the SAT treated effluent, EDTA and APECs were removed to approximately 4.3 and 0.54 microg/l, respectively, but were below the detection limit in the MF/RO treated effluent.

Carbon↗

Behavior of alkylphenol polyethoxylate metabolites during soil aquifer treatment.

The attenuation of alkylphenol polyethoxylates (APEOs) metabolites was studied at a soil aquifer treatment (SAT) site located in Arizona, USA. Two parcels of water were monitored during infiltration; one parcel was predominantly oxic while the other was predominantly anoxic. In this study, only alkylphenol ethoxycarboxylates (APECs) and carboxyalkylphenol ethoxycarboxylates (CAPECs) were detected, no short-chained APEOs were observed-even under anoxic conditions. APEO metabolites were rapidly (<7 days) removed under both aerobic and anoxic conditions. In general, the length of the ethoxycarboxylate chain decreases with depth--at depths greater than 3m, only alkylphenoxy acetic acids (AP1ECs), carboxyalkylphenoxy acetic acids (CAP1ECs), and alkylphenols (APs) remain. Under aerobic conditions, octylphenol and nonylphenol concentrations decreased by approximately 80% (w/w) within 3m of the ground surface. Under anoxic conditions however, alkylphenol concentrations increased by approximately 200% during the first 1.5m and then decreased during the next 1.5m; overall, under anoxic conditions, alkylphenol concentrations increased by approximately 38% within 3m. During infiltration, APEC and CAPEC concentrations decrease by more than 95% within 3m of SAT. Alternate flooding and drying cycles appear to enhance overall APEO metabolite removal efficiencies.

Acetates↗

Positron emission tomography during transcranial magnetic stimulation does not require mu-metal shielding.

Recording brain activity using positron emission tomography (PET) during the stimulation of different parts of the brain by transcranial magnetic stimulation (TMS) permits the mapping of neural connections in the living human brain. However, controversy remains regarding the need for micro-metal shielding of the PET scanner during magnetic stimulation. The aim of this study was to test the effects of magnetic fields generated by TMS on PET data acquisition. With TMS-on and -off in the PET field of view, transmission scans with a (68)Ge/(68)Ga pin source and emission scans with an uniform phantom filled with water and (18)F were acquired. The frequency and intensity of stimulation were set at 3-5 Hz and 70-80% of the maximum output of the stimulator, respectively. The TMS coil was placed at several locations inside the PET gantry, and the main field direction of the TMS coil was varied between parallel and perpendicular orientation to the scanner's axis. Qualitative and quantitative evaluation of the sinograms of transmission PET scans and reconstructed emission images indicated no measurable differences between TMS-on and -off and post-TMS conditions for any position or orientation. The long distance between the TMS coil and the detector block in the PET scanner, as well as the rapid reduction of the magnetic field with distance (3% of maximum field at 10 cm, in air), could explain the lack of TMS interference. The brief duration (approximately 250 micros) of the TMS pulses relative to the total PET acquisition time would also explain the lack of TMS effects. The lack of TMS effects on the PET scanner, as well as PET imaging without any shielding, has been reported by other laboratories.

Brain↗

MR imaging volumetry of subcortical structures and cerebellar hemispheres in normal persons.

BACKGROUND AND PURPOSE: Volume changes in subcortical structures and cerebella have been associated with localization-related epilepsy and psychiatric illnesses. This study evaluated the effect of handedness and sex on the volumes of selected subcortical structures and cerebellar hemispheres in normal persons. METHODS: Volumetric measurements were performed of the caudate heads, thalami, and cerebellar hemispheres in 34 (20 right- and 14 left-handed, 19 female and 15 male) normal persons. Amygdalar and hippocampal volumes were reported previously for these persons. All study participants completed a 10-item handedness questionnaire. The MR imaging sequence was a 3D T1-weighted gradient-echo acquisition of the whole brain (24/6 [TR/TE]; flip angle, 25 degrees). MR images were spatially normalized, and volumes were painted with a 1.0 mm(3) resolution cursor on an SGI workstation. The effects of handedness and sex on standardized volumes and right-to-left volume ratios were calculated, and volumes were compared between right and left sides for each structure. RESULTS: Handedness did not affect standardized volumes or asymmetries of the caudate heads, thalami, or cerebellar hemispheres. The volumes of subcortical structures were bilaterally larger in women than in men. Right-to-left asymmetries were significant for the caudate head and cerebellum but not for the thalamus. CONCLUSION: These findings show that women have significantly larger subcortical structures than do men after spatial normalization to account for differences in brain size. Sex-specific normal ranges may be needed for evaluating volume changes related to epilepsy or other disease processes.

Adult↗

Characteristics of biotic and abiotic removals of dissolved organic carbon in wastewater effluents using soil batch reactors.

Biodegradable dissolved organic carbon (BDOC) analyses and abiotic adsorption of dissolved organic carbon (DOC) from different wastewater effluent were conducted to evaluate biotic and abiotic removal mechanisms as a function of the initial DOC concentration and source of DOC using soil batch reactors. To obtain high DOC concentrations, a laboratory-scale reverse osmosis unit was used. It was found that BDOC fraction was independent of the initial DOC concentration and was dependent on the source of wastewater and/or the types of wastewater treatment. The BDOC fractions varied from 9 to 73%. Trickling filter effluent (Tucson, Arizona) showed the highest BDOC, ranging from 65 to 73% biodegradable, while wastewater treated by the soil aquifer treatment (SAT) (NW-4) was found to be most refractory, with DOC removals of 9 to 14%. For nitrified/denitrified tertiary effluent (Mesa, Arizona) and secondary effluent (Scottsdale, Arizona), 36 to 42% removal of DOC was observed during the BDOC test. The amount of BDOC in the wastewater depended not on the concentration of DOC, but on the effectiveness of pretreatment. Abiotic adsorption capacity of wastewater effluent varied from 6 to 18%. Molecular weight distribution analyses showed that more than 50% of DOC in the Scottsdale concentrate had a molecular weight of less than 1000 Da, and no significant change in distribution profiles occurred after approximately 12% abiotic adsorption with both soils with acclimated microorganisms (SAT soil) and soils without acclimated microorganisms (non-SAT soils). Hence, preferential adsorption was not observed and the presence of acclimated microbes did not influence adsorption.

Bioreactors↗

Analysis of soils to demonstrate sustained organic carbon removal during soil aquifer treatment.

Soil samples from column studies using five soil types and from a field site were analyzed to assess the ability of soil aquifer treatment to sustain removal of organic carbon. The soil types used in the column studies were chosen to represent a wide range of soil properties that might be used for soil aquifer treatment. Soil samples were analyzed for total organic matter, and a subset of samples was sequentially extracted to determine the effects of soil aquifer treatment. For both column studies and the field site, no accumulation of organic matter was observed below a depth of 8 cm. Near the surface, biological activity at the soil-water interface resulted in an accumulation of biomass and associated organic matter. For the column studies, the accumulation of organic matter in the top 8 cm of soil was <20% of the total organic matter applied to the columns. Soils at depths greater than 8 cm had total organic matter levels less than the original soils before soil aquifer treatment. Significant changes in extractable iron and manganese oxides were observed at the field site, which had been in operation for >10 yr with extended periods of low redox conditions. However, these changes had no apparent effect on the removal of organic carbon in the system. This study provides evidence that soil aquifer treatment can remove organic carbon without accumulation from adsorption that might eventually lead to breakthrough.

Adsorption↗