PubMed Health⌕ Search

Biomedical subjects

Peter Gehrke

Publications and source records attributed to Peter Gehrke.

9 recordsLinked to original sources

Multiscale spatial and small-scale temporal variation in the composition of Riverine fish communities.

We studied the multiscale (sites, river reaches and rivers) and short-term temporal (monthly) variability in a freshwater fish assemblage. We found that small-scale spatial variation and short-term temporal variability significantly influenced fish community structure in the Macquarie and Namoi Rivers. However, larger scale spatial differences between rivers were the largest source of variation in the data. The interaction between temporal change and spatial variation in fish community structure, whilst statistically significant, was smaller than the variation between rivers. This suggests that although the fish communities within each river changed between sampling occasions, the underlying differences between rivers were maintained. In contrast, the strongest interaction between temporal and spatial effects occurred at the smallest spatial scale, at the level of individual sites. This means whilst the composition of the fish assemblage at a given site may fluctuate, the magnitude of these changes is unlikely to affect larger scale differences between reaches within rivers or between rivers. These results suggest that sampling at any time within a single season will be sufficient to show spatial differences that occur over large spatial scales, such as comparisons between rivers or between biogeographical regions.

Animals↗

Syncrystallization: a technique for temporization of immediately loaded implants with metal-reinforced acrylic resin restorations.

BACKGROUND: Rigid temporization has been recognized to have a significant impact on the peri-implant tissue response in immediate implant loading since it reduces the mechanical stress exerted on each implant. PURPOSE: A successful protocol for immediate loading of multiple implants depends on an adequate fixation and immobility of the implants to prevent the risk of micromovements in relation to the surrounding bone. The objective of this article was to evaluate a prosthetic concept for an accelerated rigid splinting of multiple implants for same-day immediate loading with metal-reinforced provisional restorations using a technique of welding temporary implant abutments with a prefabricated titanium bar directly in the oral cavity (syncrystallization). MATERIALS AND METHODS: Between June 2004 and January 2005, immediate loading of threaded implants with a metal- reinforced acrylic resin provisional restoration at stage 1 surgery was evaluated in 40 consecutive patients. A total of 192 implants were placed in selected edentulous or partially edentulous patients using the syncrystallization technique. Once the titanium bar was welded intraorally to the abutments, opaque was applied and the provisional restoration was relined and screw-retained the same day. In addition, a comparison of deformations and stress distributions in implant-supported, metal-reinforced and nonmetal-reinforced resin provisional restorations was analyzed in the edentulous mandible by a three-dimensional finite element model (FEM). RESULTS: All of the 192 rigidly temporized immediately loaded implants osseointegrated. An implant success rate of 100% was achieved over a period of 6 months postplacement. No fracture or luting cement failure of the provisional restoration occurred during the observation time. Compared to mere acrylic superstructures, a significant reduction of deformation and strain within metal-reinforced provisional restorations was detected by FEM analysis. CONCLUSION: The results of this study indicate that the syncrystallization technique allows an expedite and adequate rigid splinting of multiple immediately loaded implants. The advantages of the technique are: (1) reduction of treatment time for immediate temporization at stage 1 surgery; (2) predictable fixation and immobility of implants in the early stages of bone healing; and (3) less time for repairing provisional restorations as a result of no or rare fracture.

Acrylic Resins↗

Five-year outcome of 111 immediate nonfunctional single restorations.

Immediate loading is a surgical-prosthetic procedure extensively used in implant dentistry. Despite its frequent use, minimal data are available on the long-term clinical success rate of immediate functional loading (IFL) and immediate nonfunctional loading (INFL) of implants. The aim of this study was to evaluate the long-term survival and bone loss of immediate nonfunctional single implant restorations in a group of patients that were monitored for 5 years. One hundred and eleven patients (41.4% men) with a median age of 40 years were included in this study. A total of 111 implants were placed. All implants were placed with a minimum insertion torque of 25 Ncm. A temporary restoration was relined with acrylic resin, trimmed, polished, and cemented or screw-retained 1 to 2 hours later. Occlusal contact was avoided in centric and lateral excursions. After provisional crown delivery, a periapical radiograph was performed by means of a customized Rinn holder device. Data were analyzed by means of Kaplan-Meier and life-table algorithms. Stratification of implant survival was performed for the available variables of interest, and comparisons were analyzed using a log-rank test. Investigated parameters were time of implant placement, bone quality, implant site, implant diameter and length, and type of implant surface enhancement. The parameters for overall success rate were defined by bone resorption <1.5 mm after the first year of loading and <0.2 mm thereafter. During the 5-year follow-up period, a survival rate of 95.5% was observed. All failures occurred within 4 months of implant loading. There were statistically significant differences regarding healed vs post-extraction implant sites (100% and 92.5%, respectively, P = .05) and type of bone (D1 vs D4 yielded 100% and 95.5%, respectively, P <.05). No differences were detected for: (1) site (100% for mandible and 94.63% for maxilla, P =-.319); (2) implant diameter (survival rates of 97.26% for <4.5-mm diameter and 92.11% for >4.5mm diameter, P = .206); (3) implant lengths (survival rates of 96.97% for implants >13 mm and 94.87% for implants <13 mm, P =.624); and (4) type of implant surface enhancement (survival rates of 94.03% for 67 cases of grit-blasted and acid-etched surfaces and a failure rate of 4 out of 5, and 94.12% for 17 cases of hydroxyapatite (HA)-coated surfaces with only 1 failure). The success rate (defined as bone resorption >1.5 mm after the first year of loading and >0.2 mm thereafter) was 97.2%. Immediate nonocclusal loading of single implants is a reliable surgical-prosthetic procedure with a low rate of implant loss and a low quantity of peri-implant bone loss over time.

Adolescent↗

Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri-implant soft tissues around titanium and zirconium oxide healing caps.

BACKGROUND: The aim of the present study in humans was to conduct a comparative immunohistochemical evaluation of vascular endothelial growth factor (VEGF) and nitric oxide synthase (NOS) expression, inflammatory infiltrate, proliferative activity expression, and microvessel density (MVD) in peri-implant soft tissues of titanium and zirconium oxide healing caps. METHODS: Five patients, three men and two women (aged 30 to 66 years; mean: 49 years), participated in this study. All patients received dental implants that were 3.8 mm in diameter and 11 mm in length. All implants were left to heal in a non-submerged (single-stage) mode. Healing caps (3.8 mm in diameter and 3.0 mm in height) were inserted in all implants. Half of the implants were supplied with standard, prefabricated caps of commercially pure titanium, whereas the other half were provided with test zirconium oxide caps. After a 6-month healing period, a gingival biopsy was performed with a circular scalpel (5.5 mm in diameter) around the healing caps of both groups, without unscrewing or removing the healing caps. The dimensions of the gingival biopsies were 1.7 mm (5.5-3.8 mm) in thickness and 3 mm in height. RESULTS: Statistically significant differences were found in the microvessel density between titanium and zirconium oxide healing caps and group II (P < or = 0.0001). Statistically significant differences were likewise found in the low and high intensities of NOS1, NOS3, and VEGF (P < or = 0.0001). In conclusion, the high intensity of NOS1, NOS3, and VEGF were mostly expressed in the titanium group, whereas the low intensity of NOS1, NOS3, and VEGF were mostly expressed in the zirconium oxide group. CONCLUSIONS: In our specimens, the inflammatory infiltrate was mostly present in the titanium specimens. Their extension was much larger than that of the zirconium oxide specimens. Higher values of MVD were observed in the titanium specimens (29.1 versus 15.8). In addition, a higher expression of VEGF intensity was observed in the peri-implant tissues of titanium healing caps, whereas predominantly lower expressions of VEGF intensity were noted around the zirconium oxide healing caps. The Ki-67 expression was higher in the titanium specimens. All these data revealed that the tissues around titanium healing caps underwent a higher rate of inflammation-associated processes, most probably correlated to the higher inflammation processes observed in these tissues. A higher intensity expression of NOS1 and NOS3 was recorded in the tissues around titanium, whereas, on the contrary, a lower intensity of expression was found in the tissues around zirconium oxide specimens. These latter data indicate that the higher expression of these two mediators could be correlated to the higher amount of bacteria present around the titanium samples.

Adult↗

Zirconium implant abutments: fracture strength and influence of cyclic loading on retaining-screw loosening.

OBJECTIVE: The purpose of this study was to determine the fracture strength of zirconium implant abutments and the torque required to unfasten the retaining screw before and after applying cyclic loading to the implant-abutment assembly. The dynamic behavior and stress distribution pattern of zirconium abutments were also evaluated. METHODS AND MATERIALS: Static and cyclic loading of 7 XiVE implants with straight Cercon zirconium abutments were simulated under worst-case conditions. Cyclic loading tests were performed via a servohydraulic dynamic testing machine at loads between 100 and 450 N, for up to 5 million loading cycles, at 15 Hz. The dynamic behavior of the zirconium abutments was analyzed by finite element modeling and Pro/Mechanica software, comparing van-der-Mises and maximum stress levels. RESULTS: Cercon zirconium-ceramic abutments exhibited a maximum fracture strength of 672 N during static loading and 269 N at 800,000 to 5 million cycles runout point, and 403 N at 10,000 cycles runout point during cyclic loading. The mean torque value required to unfasten the abutment retaining screws after (initial) tightening was 21 Ncm +/- 1 and 20 Ncm +/- 1 (measurement accuracy +/- 2 Ncm) after loading with up to 5 million cycles respectively. Torque values decreased minimally and screw loosening did not occur. Within the limited number of test specimens (7), the difference was statistically significant (P = .015). FEM analysis displayed higher stress peaks up to 800 MPa at the cervical aspect of the zirconium abutment and at the apical third of its retaining screw at an external load of 250 N. CONCLUSION: Within the limitations of this study, zirconium implant abutments exceeded the established values for maximum incisal bite forces reported in the literature and tightly fit into the titanium implant after several millions of loading cycles.

Bite Force↗

Clinical outcome of 802 immediately loaded 2-stage submerged implants with a new grit-blasted and acid-etched surface: 12-month follow-up.

PURPOSE: The aim of this study was to evaluate the clinical outcome of delayed or immediately loaded implants of 3 different implant macrodesigns. The hypothesis was that no significant differences in implant success would be observed between immediately and delayed loaded implants. MATERIALS AND METHODS: Between July 2003 and December 2003, 321 patients were consecutively enrolled for this study. Immediate loading was performed in cases where the implant stability quotient (ISQ) values were > 60 (as determined by resonance frequency analysis) and implant insertion torque was > 25 Ncm. In the case of delayed loading, a submerged technique (2-stage) or a single-stage procedure was used. The following variables were statistically analyzed with logistic regression: implant length, implant diameter, implant type, implant site, insertion torque, ISQ, and type of loading (immediate or delayed). RESULTS: Eight hundred two implants were placed. Immediate loading was chosen for 423 implants and delayed loading for 379 implants. All implants were followed up for a minimum of 12 months after prosthetic loading. Only 3 implants were lost, with an overall success rate of 99.6%. No statistically significant differences were found for any variables between the failures in the 2 groups (immediate loading protocol versus delayed loading). Implants with a crestal bone loss greater than 0.2 mm during the first year of observation (69 cases) were evaluated as a group; within this subset, only ISQ value (P < .004), implant length (P < .002), and implant type (P < .049) had a statistically significant effect on crestal bone resorption. CONCLUSIONS: Based upon this study of 802 implants, no significant differences in implant success were observed between the 2 groups.

Acid Etching, Dental↗