PubMed Health⌕ Search

Biomedical subjects

Peter Gründler

Publications and source records attributed to Peter Gründler.

5 recordsLinked to original sources

Interaction of tin(II) and arsenic(III) with DNA at the nanostructure film modified electrodes.

Biosensors based on DNA and DNA-carbon nanotubes film immobilized at the surface of a screen-printed carbon electrode were used for simple in vitro tests of chemical toxicity. The damage to DNA caused by tin(II) and arsenic(III) compounds as components of specific reaction media was evaluated by means of an electrochemical DNA marker, [Co(phen)3](3+), as the portion of original dsDNA which survives an incubation of the biosensor in the cleavage medium. The results were confirmed by the electrically heated electrode and by the measurement of the DNA guanine moiety signal.

Arsenic↗

DNA hybridization detection at heated electrodes.

The detection of DNA hybridization is of central importance to the diagnosis and treatment of genetic diseases. Due to cost limitations, small and easy-to-handle testing devices are required. Electrochemical detection is a promising alternative to evaluation of chip data with optical readout. Independent of the actual readout principle, the hybridization process still takes a lot of time, hampering daily use of these techniques, especially in hospitals or doctor's surgery. Here we describe how direct local electrical heating of a DNA-probe-modified gold electrode affects the surface hybridization process dramatically. We obtained a 140-fold increase of alternating current voltammetric signals for 20-base ferrocene-labeled target strands when elevating the electrode temperature during hybridization from 3 to 48 degrees C while leaving the bulk electrolyte at 3 degrees C. At optimum conditions, a target concentration of 500 pmol/L could be detected. Electrothermal regeneration of the immobilized DNA-probe strands allowed repetitive use of the same probe-modified electrode. The surface coverage of DNA probes, monitored by chronocoulometry of hexaammineruthenium(III), was almost constant upon heating to 70 degrees C. However, the hybridization ability of the probe self-assembled monolayer declined irreversibly when using a 70 degrees C hybridization temperature. Coupling of heated electrodes and highly sensitive electrochemical DNA hybridization detection methods should enhance detection limits of the latter significantly.

DNA↗

Application of heated electrodes operating in a non-isothermal mode for interference elimination with amperometric biosensors.

Heated electrodes were applied for the non-isothermal operation of amperometric glucose biosensors based on glucose oxidase immobilised on the electrode surface by entrapment within a polymer layer. The localised deposition of the polymer film under simultaneous entrapment of the enzyme was achieved by an electrochemically induced pH-modulation in the diffusion zone in front of the electrode, thus altering the solubility of the polymer chains. This non-manual sensor preparation protocol could be successfully used for the modification of a novel indirectly heated electrode. The non-isothermal operating mode allows working at the optimum temperature of the enzyme sensors without any thermal distortion of the bulk solution. Increased surface temperature of the sensor thus accelerates transport as well as kinetic processes, resulting in an enhanced amperometric signal. In the presence of interfering compounds such as ascorbic acid, the proposed technique allows use of the diverging thermal impact on the sensing process, for different electrochemically active compounds, for a deconvolution of the amperometric signal at different electrode temperatures. A calculation method for determination of glucose in the presence of one interfering compound is presented as a basis for a calculative interference elimination.

Journal Article↗

Hydrodynamics with heated microelectrodes.

Voltammetry with continuously heated microelectrodes yields well-defined sigmoidal current-voltage curves. Unlike hydrodynamic electrodes, the surface temperature of a heated electrode can be adjusted arbitrarily within a certain range. Inside a thermal layer, a virtually stagnant diffusion layer of constant thickness delta(diff) exists. delta(diff )is independent of temperature within a certain range. On the basis of this theory, equations are derived which play a similar role to, for instance, the Levich equation for the rotating disk electrode. Reasonable agreement of the derived relationship with the results from voltammetric experiments is obtained.

Journal Article↗

Electrochemical analysis of nucleic acids at boron-doped diamond electrodes.

Highly conductive boron-doped diamond (BDD) electrodes are well suited for performing electrochemical measurements of nucleic acids in aqueous solution under diffusion-only control. The advantageous properties of this electrodic material in this context include reproducibility and the small background currents observed at very positive potentials, along with its robustness under extreme conditions so offering promising capabilities in future applications involving thermal heating or ultrasonic treatment. tRNA, single and double stranded DNA and 2'-deoxyguanosine 5'-monophosphate (dGMP) have been studied and well defined peaks were observed in all cases, directly assignable to the electro-oxidation of deoxyguanosine monophosphate.

Boron↗