PubMed Health⌕ Search

Biomedical subjects

Peter Haddock

Publications and source records attributed to Peter Haddock.

2 recordsLinked to original sources

Stabilization versus inhibition of TAFIa by competitive inhibitors in vitro.

Two competitive inhibitors of TAFIa (activated thrombin-activable fibrinolysis inhibitor), 2-guanidinoethylmercaptosuccinic acid and potato tuber carboxypeptidase inhibitor, variably affect fibrinolysis of clotted human plasma. Depending on their concentration, the inhibitors shortened, prolonged, or had no effect on lysis in vitro. The inhibitor-induced effects were both tissue-type plasminogen activator (tPA) and TAFIa concentration-dependent. Inhibitor-dependent prolongation was favored at lower tPA concentrations. The magnitude of the prolongation increased with TAFIa concentration, and the maximal prolongation observed at each TAFIa concentration increased saturably with respect to TAFIa. A theoretical maximal prolongation of 20-fold was derived from a plot of the maximum prolongation versus TAFIa. This represents, for the first time, a measurement of the maximal antifibrinolytic potential of TAFIa in vitro. Because TAFIa spontaneously decays, the stabilization of TAFIa was investigated as a mechanism explaining the inhibitor-dependent prolongation of lysis. Both inhibitors stabilized TAFIa in a concentration-dependent, non-saturable manner. Although their KI values differed by three orders of magnitude, TAFIa was identically stabilized when the fraction of inhibitor-bound TAFIa was the same. The data fit a model whereby only free TAFIa decays. Therefore, the variable effects of competitive inhibitors of TAFIa on fibrinolysis can be rationalized in terms of free TAFIa and lysis time relative to the half-life of TAFIa.

Binding, Competitive↗

High-throughput screening for ion channel modulators.

Ion channels present a group of targets for major clinical indications, which have been difficult to address due to the lack of suitable rapid but biologically significant methodologies. To address the need for increased throughput in primary screening, the authors have set up a Beckman/Sagian core system to fully automate functional fluorescence-based assays that measure ion channel function. They apply voltage-sensitive fluorescent probes, and the activity of channels is monitored using Aurora's Voltage/Ion Probe Reader (VIPR). The system provides a platform for fully automated high-throughput screening as well as pharmacological characterization of ion channel modulators. The application of voltage-sensitive fluorescence dyes coupled with fluorescence resonance energy transfer is the basis of robust assays, which can be adapted to the study of a variety of ion channels to screen for both inhibitors and activators of voltage-gated and other ion channels.

Automation↗