PubMed Health⌕ Search

Biomedical subjects

Peter Hassenpflug

Publications and source records attributed to Peter Hassenpflug.

3 recordsLinked to original sources

Sensorless freehand 3D ultrasound in real tissue: speckle decorrelation without fully developed speckle.

It has previously been demonstrated that freehand 3D ultrasound can be acquired without a position sensor by measuring the elevational speckle decorrelation from frame to frame. However, this requires that the B-scans contain significant amounts of fully developed speckle. In this paper, we show that this condition is rarely satisfied in scans of real tissue, which instead exhibit fairly ubiquitous coherent scattering. By examining the axial and lateral correlation functions, we propose an heuristic technique to quantify the amount of coherency at each point in the B-scans. This leads to an adapted elevational decorrelation scheme which allows for the coherent scattering. Using the adapted scheme, we demonstrate markedly improved reconstructions of animal tissue in vitro.

Algorithms↗

Speckle classification for sensorless freehand 3-D ultrasound.

Despite being a valuable tool for volume measurement and the analysis of complex geometry, the need for an external position sensor is holding up the clinical exploitation of freehand 3-D ultrasound. Some sensorless systems have been developed, using speckle decorrelation for out-of-plane distance estimation, but their accuracy is still not as good as that of sensor-based systems. Here, we examine the widely held belief that accuracy can be improved by limiting the distance measurements to patches of ultrasound data containing fully developed speckle. Without speckle detection, we observe that scan separation is systematically underestimated by 33.1% in biological tissue. We describe a number of speckle detectors and show that they reduce the underestimate to about 25%. We conclude that speckle classification can improve the quality of distance estimation, but not sufficiently to achieve accurate, metric reconstruction of the insonified volume.

Humans↗

Evaluation of visualization techniques for image-guided navigation in liver surgery.

A substantial component of an image-guided surgery system (IGSS) is the kind of three-dimensional (3D) presentation to the surgeon because the visual depth perception of the complex anatomy is of significant relevance for orientation. Therefore, we examined in this contribution four different visualization techniques, which were evaluated by eight surgeons. The IGSS developed by our group supports the intraoperative orientation of the surgeon by depicting a visualization of the spatially tracked surgical instruments with respect to intrahepatic vessels that have to be conserved vitally, the tumor, and preoperatively calculated resection planes. In the prelimenary trial presented here we examined the human ability to percept an intraoperative virtual scene and to solve given navigation tasks. The focus of the experiments was to measure the ability of eight surgeons to orientate intrahepaticaly and to transfer the percepted spatial relation to movements in real space. An autostereoscopic visualization with a prism-based display yielded that the navigation can be performed faster and more accurately than with the other visualization techniques.

Anatomy, Regional↗