PubMed Health⌕ Search

Biomedical subjects

Peter Herzog

Publications and source records attributed to Peter Herzog.

13 recordsLinked to original sources

A randomized multi-center phase II trial of the angiogenesis inhibitor Cilengitide (EMD 121974) and gemcitabine compared with gemcitabine alone in advanced unresectable pancreatic cancer.

BACKGROUND: Anti-angiogenic treatment is believed to have at least cystostatic effects in highly vascularized tumours like pancreatic cancer. In this study, the treatment effects of the angiogenesis inhibitor Cilengitide and gemcitabine were compared with gemcitabine alone in patients with advanced unresectable pancreatic cancer. METHODS: A multi-national, open-label, controlled, randomized, parallel-group, phase II pilot study was conducted in 20 centers in 7 countries. Cilengitide was administered at 600 mg/m2 twice weekly for 4 weeks per cycle and gemcitabine at 1000 mg/m2 for 3 weeks followed by a week of rest per cycle. The planned treatment period was 6 four-week cycles. The primary endpoint of the study was overall survival and the secondary endpoints were progression-free survival (PFS), response rate, quality of life (QoL), effects on biological markers of disease (CA 19.9) and angiogenesis (vascular endothelial growth factor and basic fibroblast growth factor), and safety. An ancillary study investigated the pharmacokinetics of both drugs in a subset of patients. RESULTS: Eighty-nine patients were randomized. The median overall survival was 6.7 months for Cilengitide and gemcitabine and 7.7 months for gemcitabine alone. The median PFS times were 3.6 months and 3.8 months, respectively. The overall response rates were 17% and 14%, and the tumor growth control rates were 54% and 56%, respectively. Changes in the levels of CA 19.9 went in line with the clinical course of the disease, but no apparent relationships were seen with the biological markers of angiogenesis. QoL and safety evaluations were comparable between treatment groups. Pharmacokinetic studies showed no influence of gemcitabine on the pharmacokinetic parameters of Cilengitide and vice versa. CONCLUSION: There were no clinically important differences observed regarding efficacy, safety and QoL between the groups. The observations lay in the range of other clinical studies in this setting. The combination regimen was well tolerated with no adverse effects on the safety, tolerability and pharmacokinetics of either agent.

Adult↗

Pulmonary abnormalities in immunocompromised patients: comparative detection with parallel acquisition MR imaging and thin-section helical CT.

PURPOSE: To compare parallel acquisition magnetic resonance (MR) imaging with thin-section helical computed tomography (CT) for depiction of pulmonary abnormalities suggestive of pneumonia in immunocompromised patients. MATERIALS AND METHODS: The institutional review board approved this study; prior consent was obtained. Thirty consecutive neutropenic patients (10 women, 20 men; mean age, 51 years +/- 15 [standard deviation]; range, 25-75 years) with fever of unknown origin or clinical signs and symptoms of lung infection were examined with breath-hold single-shot half-Fourier turbo spin-echo MR imaging. To reduce image blurring and increase MR signal in the lungs, the echo time was shortened with generalized autocalibrating partially parallel acquisition (GRAPPA). Patients underwent thoracic CT (four detector rows and 1-mm section thickness [4 x 1 mm]; pitch, 6) as reference standard. Pulmonary abnormalities (ill-defined nodules, ground-glass opacity areas, and consolidation), their location and distribution, and lesion characteristics were analyzed at MR imaging by three readers, blinded to results of CT, in consensus. Frequencies were calculated for each feature; paired Wilcoxon rank sum test was used to examine whether differences between CT and MR imaging features were statistically significant (alpha < .05). Bonferroni adjustments were performed. Overall sensitivity, specificity, and positive and negative predictive values were determined. RESULTS: Twenty-two patients had pulmonary abnormalities at CT. In 21 (95%) patients, pneumonia was correctly diagnosed with MR imaging. One false-negative finding occurred in a patient with ill-defined nodules smaller than 1 cm at CT. One false-positive finding with MR imaging was the result of blurring and respiratory artifacts (sensitivity, 95%; specificity, 88%; positive predictive value, 95%; negative predictive value, 88%). There was no significant difference in lesion location and distribution. CONCLUSION: With parallel imaging (GRAPPA technique) and fast MR imaging, detection of pulmonary abnormalities is almost as good as with CT. MR imaging has a slight disadvantage in its lower capability to assist in characterization of specific internal features, such as cavitations.

Adult↗

Relevance of correction for rotational targeting error in functional neurosurgery.

OBJECTIVE: A prospective study is presented on the amount of targeting error that is due to rotational deviations between the atlas and the stereotactic coordinate system. MATERIALS AND METHODS: We investigated 14 volunteers with a stereotactic frame fixed to their heads by tight adhesive bands. Sagittal, coronal and axial T2-weighted MRI scans, as well as MPRage sequences, were performed. The anterior and posterior commissures and one additional point on the midline (the septum pellucidum) were determined on the axial T2-weighted images. Bilateral atlas coordinates for the subthalamic nucleus (STN), globus pallidus pars interna (GPi) and nucleus ventralis intermedius (Vim) were transformed to stereotactic frame coordinates, either without correction or by 2-point or 3-point correction. A total of 896 coordinates (x, y, z for the STN, GPi and Vim in both hemispheres) were calculated. RESULTS: Although the mean differences between the two algorithms (0.24 +/- standard deviation of 0.33 mm) were within the range of system-immanent inaccuracies in MRI-guided stereotaxy, deviations of up to 2.8 mm occurred. No significant correlation was found regarding the amount of rotational angle and the differences in x-, y-, or z-coordinates when 2-point and 3-point transformations were compared. CONCLUSIONS: The reliability of meticulous trajectory planning might be compromised significantly by using only 2-point-based correction or no calculations at all.

Adult↗

Approaches to CT perfusion imaging in pulmonary embolism.

Computed tomography (CT) has become an increasingly accepted technique and is the method of choice for direct visualization of pulmonary emboli (PE). The quantitative assessment of tissue perfusion may yield more important information for patient management than the direct visualization of emboli by CT alone. Several attempts have been made to measure pulmonary blood flow by administration of intravenous contrast material. In this article, various experimental CT approaches for visualization and quantification of pulmonary perfusion are discussed. Ideally, CT will be able to provide both structural and functional information. Simple measurement of lung density before and after intravenous contrast delivery has been performed with single-slice CT technology using region-of-interest methodology. For electron-beam CT, a repeated data acquisition on a 7.6-cm lung volume has proven to be technically feasible. Using such dynamic scanning, reduced blood flow was observed in occluded lung segments. Color-encoded parenchymal density distribution in the axial, coronal, and sagittal planes was derived from thin collimation data sets using four-row multi-slice spiral CT (MSCT). Initial animal data from 16-slice MSCT offer a real CT-subtraction technique of the entire chest for the first time.

Color↗

High-resolution whole-body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomography-computed tomography: experience on a 32-channel system.

OBJECTIVE: The objective of this study was to compare the accuracy in staging of various malignant tumors with whole-body magnetic resonance imaging (WB-MRI) using parallel imaging (PAT) and positron emission tomography-computed tomography (PET-CT). MATERIALS AND METHODS: In a prospective study, 41 patients withoncologic diseases underwent [F]-fluoro-2-deoxy-D-glucose PET-CT for tumor staging and WB-MRI on a 32-channel-scanner with the use of PAT. Coronal T1w and STIR sequences at 5 body levels, axial HASTE imaging of the lung, and contrast-enhanced T1w sequences of the liver, brain, and abdomen were performed. TNM stage was assessed for both modalities in a separate consensus reading using histologic results and radiologic follow up within 6 months as the standard of reference. RESULTS: Three primary and 4 recurrent tumors were detected; one recurrent tumor was missed with WB-MRI. Sixty benign and 60 malignant lymph nodes were detected with a sensitivity of 98% and specificity of 83% for PET-CT and 80%/75% for WB-MRI, respectively. One hundred ninety-one malignant and 77 benign distant lesions were detected with a sensitivity/specificity of 82% for PET-CT and 96%/82% for WB-MRI. Accuracy for correct TNM staging was 96% for PET-CT and 91% for WB-MRI. CONCLUSION: WB-MRI and PET-CT are reliable imaging modalities for tumor staging. WB-MRI is highly sensitive in detecting distant metastases; PET-CT is superior in lymph node staging. PAT makes high-resolution WB-MRI feasible within less than 1 hour.

Adult↗

Computer-aided diagnosis as a second reader: spectrum of findings in CT studies of the chest interpreted as normal.

STUDY OBJECTIVES: To assess the performance of an automated computer-aided detection (CAD) system as a second reader on chest CT studies interpreted as normal at routine clinical interpretation. DESIGN: Chest CT studies were processed using a prototype CAD system for automated detection of lung lesions. Three experienced radiologists analyzed each CAD finding and confirmed or dismissed the marked image features as lung lesions. Noncalcified, focal lung lesions were classified according to size as being of high (> or = 10 mm), intermediate (5 to 9 mm), or low (< or = 4 mm) significance. SETTING: Two sub-specialized academic tertiary referral centers in the United States and Germany. PATIENTS: Chest CT studies were performed in 100 patients, with results initially reported as normal at clinical double reading. Indications for chest CT were suspected pulmonary embolism (PE) [n = 33], lung cancer screening in a high-risk population (n = 28), or follow-up for a cancer history (n = 39). INTERVENTIONS: Reevaluation of all chest CT studies for focal lung lesions with the CAD system as a second reader. MEASUREMENTS: Prevalence and spectrum of lung lesions missed at routine clinical interpretation but found by the CAD system. RESULTS: In 33% (33 of 100 patients), CAD detected significant lung lesions that were not previously reported. Fifty-three significant lesions were detected (mean, 1.6 lesions per case), of which 5 lesions (9.4%) were of high significance, 21 lesions (39.6%) were of intermediate significance, and 27 lesions (50.9%) were of low significance. In the PE group, the lung cancer screening group, and the group with a cancer history, four patients (12.1%), six patients (21.4%), and nine patients (23.1%), respectively, had focal lung lesions of high and/or intermediate significance. The false-positive rate of the CAD system was an average of 1.25 per case (range, 0 to 11). CONCLUSIONS: Significant lung lesions are frequently missed at routine clinical interpretation of chest CT studies but may be detected if CAD is used as an additional reader.

Adult↗

18F-FDG PET/CT for staging of penile cancer.

UNLABELLED: The value of PET or PET/CT with (18)F-FDG for the staging of penile cancer has yet to be determined. The objective of this study was to investigate the pattern of (18)F-FDG uptake in the primary malignancy and its metastases and to determine the diagnostic value of (18)F-FDG PET/CT in the staging and restaging of penile cancer. METHODS: Thirteen patients (mean +/- SD age, 64 +/- 14.0 y) with suspected penile cancer or suspected recurrent disease were examined with a Gemini PET/CT system (200 MBq of (18)F-FDG). The reference standard was based on histopathologic findings obtained at biopsy or during surgery. RESULTS: Both the primary tumor and regional lymph node metastases exhibited a pattern of (18)F-FDG uptake typical for malignancy. Sensitivity in the detection of primary lesions was 75% (6/8), and specificity was 75% (3/4). On a per-patient basis, sensitivity in the detection of lymph node metastases was 80% (4/5), and specificity was 100% (8/8). On a nodal-group basis, PET/CT showed a sensitivity of 89% (8/9) in the detection of metastases in the superficial inguinal lymph node basins and a sensitivity of 100% (7/7) in the deep inguinal and obturator lymph node basins. The mean +/- SD maximum standardized uptake value for the 8 primary lesions was 5.3 +/- 3.7, and that for the 16 lymph node metastases was 4.6 +/- 2.0. CONCLUSION: According to our results, the main indication for (18)F-FDG PET in the primary staging or follow-up of penile cancer patients may be the prognostically crucial search for lymph node metastases. With the use of a PET/CT unit, the additional information provided by CT may be especially useful for planning surgery. Implementing (18)F-FDG PET and PET/CT in future staging algorithms may lead to a more precise and stage-appropriate therapeutic strategy. Furthermore, invasive procedures with a high morbidity rate, such as general bilateral lymphadenectomy, may be avoided.

Adult↗

High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering.

PURPOSE: To compare high-resolution T2-weighted images of the liver with and without integrated parallel acquisition techniques (iPAT) using either breath-hold sequences in combination with prospective acquisition motion correction (PACE) or respiratory triggering. MATERIALS AND METHODS: Ten volunteers and 10 patients underwent each four different high-resolution fast spin echo (FSE) T2-weighted sequences with 5 mm slice thickness and a full 320 matrix: a multi-breath-hold FSE sequence with and without iPAT and PACE and a respiratory-triggered FSE sequence with and without iPAT. Image quality was rated with a five-point scale by two independent readers. Signal intensity measurements were performed on a water phantom. RESULTS: The sequences with iPAT required a substantially shorter acquisition time without loss of image quality. Overall image quality was rated equal for all sequences by both readers. Image time for nine slices with iPAT was 13 seconds (19 seconds without iPAT) with multi-breath-hold and on average 4:00 minutes (7:02 minutes without iPAT) with respiratory triggering. Imaging with the PACE technique resulted in more correct positioning of the image stacks. CONCLUSION: T2-weighted fast imaging with iPAT is feasible and results in high-quality images within a short acquisition time. Overall image quality is not negatively affected by iPAT.

Adult↗

Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating.

The aim of this study was to reduce radiation exposure in multislice CT (MSCT) coronary artery calcium screening using different tube settings, and to determinate its impact on the detection and quantification of coronary artery calcification. Forty-eight patients underwent routine MSCT coronary artery calcium scoring (Somatom VolumeZoom, Siemens, Forchheim, Germany) with retrospective ECG-gated data acquisition. Scanning was performed with a 4 x 2.5-mm collimation. In each patient data acquisition was performed twice using tube settings of 120 kVp with 133 mAs (protocol 1) and of 80 kVp with 300 mAs (protocol 2). Together with the 80-kVp protocol additional online ECG-related tube current modulation (ECG pulsing) was used. Three-millimeter overlapping slices (increment 1.5 mm) were calculated for each data set. Semi-automated calcium quantification was performed calculating absolute Ca-hydroxylapatite mass. In addition to patient examinations, the radiation exposure for both protocols was evaluated using computed tomography dose index (CTDI) phantom measurements. Protocol 2 showed a significantly lower patient radiation exposure than protocol 1 (0.72 vs 2.04 mSv; p<0.0001). The CTDI phantom measurements revealed a 65% reduction of radiation dose. Calcium scoring results of both protocols showed a high correlation ( r=0.99; p<0.0001) for absolute Ca-Hydroxylapatite mass measurements. Using 80-kVp protocols patient radiation exposure can be significantly reduced in MSCT coronary artery calcium screening without affecting the detection and quantification of coronary artery calcification; therefore, this technique should be used with retrospective ECG-gated cardiac CT examinations in patients with regular sinus rhythm.

Calcinosis↗