Conservative treatment reduced pain and was as effective as sutures in hand lacerations.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Peter J Stern.
Explore the source record for details and available documents.
BACKGROUND: The long-term results of silicone metacarpophalangeal arthroplasty in patients with rheumatoid arthritis are uncertain. The purpose of this investigation was to evaluate the subjective, objective, and radiographic outcomes at the time of long-term follow-up. METHODS: Patients with rheumatoid arthritis who underwent simultaneous silicone metacarpophalangeal joint arthroplasties of all four fingers by one surgeon were eligible for inclusion in the study. The results of a total of 208 arthroplasties in fifty-two hands of thirty-six patients were evaluated at an average of fourteen years postoperatively. Active metacarpophalangeal joint motion, ulnar drift, and radiographs were assessed. The radiographs were reviewed for changes in bone length, erosions, and implant fractures. The Michigan Hand Outcomes Questionnaire (MHQ) was administered to the patients. RESULTS: The mean arc of motion of the metacarpophalangeal joints improved from 30 degrees preoperatively to 46 degrees immediately after the surgery but decreased to 36 degrees at the time of final follow-up. The mean extension deficit of the metacarpophalangeal joints improved from 57 degrees preoperatively to 11 degrees immediately after the surgery but worsened to 23 degrees at the time of final follow-up. The mean ulnar drift improved from 26 degrees preoperatively to <5 degrees in the immediate postoperative period and then recurred to an average of 16 degrees at the time of final follow-up. Implant fractures were associated with increased ulnar drift (p < 0.001). Bone reaction adjacent to the implant was demonstrated by bone-shortening in most patients and by erosions in 29% of the patients. One hundred and thirty implants (63%) were broken and forty-five (22%) more were deformed at the time of final follow-up. The MHQ score averaged 48 of 100 points. The patients expressed satisfaction with the function of only 38% of the hands, and only 27% of the hands were pain-free at the time of final follow-up. A greater degree of ulnar drift was associated with decreased patient satisfaction and a decreased score for the cosmetic appearance (p </= 0.01). CONCLUSIONS: The outcome after silicone metacarpophalangeal joint arthroplasty in patients with rheumatoid arthritis worsens with long-term follow-up. Given these findings, the indications for and long-term expectations of silicone metacarpophalangeal arthroplasty must be carefully examined in light of the improvements in the medical management of rheumatoid disease.
The purpose of this study was to determine success rates of 1 or more aspirations on flexor tendon sheath ganglions compared with surgical excision and to determine what treatment method is most cost-effective. Data were collected from documented history and physical examinations, operative reports, billing records, and telephone interviews. Of the 259 patients coded as having flexor tendon sheath ganglions, 175 met the inclusion criteria. In addition, 2001 Medicare-assigned relative value units and fees were used to calculate the most cost-effective treatment. Of the 141 patients treated with aspiration, 66% exhibited no recurrence after 2 consecutive treatments. Thirteen of 14 patients (93%) who had ganglions excised without prior aspiration showed no recurrence. All 29 patients who had excision after 1 (n = 24) or 2 (n = 5) failed aspirations were cured. Because few patients require excision after 2 aspirations, the most cost-effective treatment for recurrent flexor tendon sheath ganglions is 2 aspirations before excision.
Thumb carpometacarpal arthritis is seen commonly in postmenopausal women after attenuation of the volar beak ligament. Less commonly, it may be seen in young men after an intraarticular fracture of the base of the thumb metacarpal. Although most patients respond well to nonoperative measures, two good surgical treatment options exist. Arthroplasty is performed typically in older, low-demand women, and arthrodesis is often recommended in younger patients. Recent studies have demonstrated similar outcomes with these two procedures. Thumb carpometacarpal arthrodesis is a reliable and durable treatment with very good results. It provides excellent strength, satisfactory thumb range of motion, and excellent patient satisfaction. The procedure is contraindicated in patients with arthritis in the scaphotrapeziotrapezoid joint. The surgical technique is straightforward, and fusion is usually performed with either a plate and screw construct or with multiple Kirschner wires. Although failure is rare, good salvage procedures exist. Complications are uncommon but include nonunion in approximately 13% of patients and pain related to prominent hardware.
Explore the source record for details and available documents.
Open reduction and volar neutralization plate fixation avoids problems associated with dorsal plate fixation (eg, extensor tenosynovitis and tendon rupture) and minimizes the necessity for secondary plate removal. Volar plating is a useful technique for treating dorsally displaced distal radius fractures with minimal scarring, infrequent bone grafting, and safe early wrist mobilization.
PURPOSE: To evaluate the clinical results of a pyrolytic carbon resurfacing proximal interphalangeal joint (PIPJ) arthroplasty in patients with osteoarthritis. METHODS: A retrospective review of 18 PIPJ arthroplasties in 8 women with severe osteoarthritis performed by a single surgeon was completed with an average follow-up period of 13 months. Clinical assessment included range of motion (ROM), stability, and deformity. Radiographs were reviewed for evidence of loosening, subsidence, fracture, and osseointegration. Six patients, representing 16 joints, answered a questionnaire regarding pain relief, appearance, and overall satisfaction with the arthroplasty. Complications also were recorded. RESULTS: The average preoperative ROM was 10 degrees to 63 degrees, and the average postoperative ROM was 18 degrees to 71 degrees. Although the average arc of motion was unchanged, 9 joints had an increase in ROM and 9 joints had a decrease in ROM. All joints were stable laterally. Radiographic review indicated 2 joints with loosening at 4 months after surgery. Complications included 8 squeaky joints, 5 joint contractures, and 2 dislocations. Pain was relieved completely in 8 joints, and the pain rating on a visual analog scale was 3.6 out of 10 for the 8 patients who had residual pain. Patients were satisfied completely with the results of 9 joints. Although there was residual deformity in 4 joints, patients believed that 15 of 16 joints had improved in appearance. Five of 6 patients responded that they would have the surgery again. There have been no secondary procedures performed by us. CONCLUSIONS: The insertion of pyrolytic carbon implants for PIPJ arthroplasty is a technically demanding procedure, but it has the potential to achieve pain relief, stability, satisfactory ROM, and correction of the deformity; however, the results in this review were unpredictable and may not be superior to those achieved with other methods of arthroplasty. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic, Level IV.
PURPOSE: To determine if a consensus definition exists in the literature and among hand surgeons for Kaplan's cardinal line (KCL) and to determine the relationship of the various descriptions to deep structures. METHODS: The literature contains 4 different descriptions of KCL. Members of the American Society for Surgery of the Hand were surveyed to determine which line they understand to be the correct description of KCL. The 4 variations of KCL were marked on cadavers and the lines' precision in identifying deep structures was measured. RESULTS: Our survey showed that there is no consensus regarding the definition of KCL. Fifty percent of the surgeons surveyed use KCL as a surgical landmark. A line extended along the abducted thumb and a line from the apex of the interdigital fold between the thumb and the index finger to the hook of hamate most closely reproduce the location of deep structures of the hand and are the farthest from and always proximal to the superficial palmar arch. The line from the apex of the interdigital fold between the thumb and the index finger parallel to the middle crease of the palm and the line from the apex of the interdigital fold between the thumb and the index finger to a point 2 cm distal to the pisiform are the farthest from the motor branch of the median nerve and are markedly closer to the superficial palmar arch. All lines are radial and distal to the motor branch of the median nerve. CONCLUSIONS: Ambiguity exists regarding the definition of KCL among hand surgeons and in the literature. Although no single line is ideal for locating all deep structures, line C is the safest line to identify hand anatomy. Kaplan's cardinal line does not locate the deep structures of the hand accurately but may assist in making palmar incisions.