PubMed Health⌕ Search

Biomedical subjects

Peter James

Publications and source records attributed to Peter James.

22 records · Page 2Linked to original sources

Reproducibility of tryptic digestion investigated by quantitative fourier transform ion cyclotron resonance mass spectrometry.

In this study, the reproducibility of tryptic digestion of complex solutions was investigated using liquid chromatography Fourier transform ion cyclotron resonance (LC FT-ICR) mass spectrometry. Tryptic peptides, from human cerebrospinal fluid, (CSF) were labeled with Quantification-Using-Enhanced-Signal-Tags (QUEST)-markers, or 1-([H4]nicotinoyloxy)- and 1-([D4]nicotinoyloxy)-succinimide ester markers. The analysis was performed on abundant proteins with respect-to-intensity ratios and sequence coverage and obtained by comparing differently labeled components from one or different pools. To interpret the dynamics in the proteome, one must be able to estimate the error introduced in each experimental steps. The intra sample variation due to derivatization was approximately 10%. The inter sample variation depending on derivatization and tryptic digestion was not more than approximately 30%. These experimental observations provide a range for the up- and down-regulations that are possible to study with electrospray ionization LC FT-ICR mass spectrometry.

Adolescent↗

Automated protein identification by the combination of MALDI MS and MS/MS spectra from different instruments.

The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.

Automation↗

Automated prescan function for scanning fluorescently stained 2D-PAGE gels.

To automate the acquisition of images from fluorescently stained gels, the power of the excitation laser(s) must be optimized for each sample to prevent spot saturation (or to allow unimportant spots to saturate) yet still retaining sensitivity. In this work, we describe the implementation and effectiveness of a pre-scan function in a robotic solution for the automation of 2D gel scanning.

Algorithms↗

The protein expression of Streptococcus pyogenes is significantly influenced by human plasma.

During the course of infection, the common human pathogen Streptococcus pyogenes encounters plasma. We show that plasma causes S. pyogenes to rapidly remodel its cellular metabolism and virulence pathways. We also identified a variant of the major virulence factor, M1 protein, lacking 13 amino acids at the NH(2)-terminus in bacteria grown with plasma. The pronounced effect of plasma on protein expression, suggests this is an important adaptive mechanism with implications for S. pyogenes pathogenicity.

Amino Acids↗