Requirements for room temperature shimming of the human brain.

Room temperature (RT) shims are used routinely in MRI to remove global and local B(0) field inhomogeneity introduced by the subject. Most clinical scanners use only second-order spherical harmonic terms, but with the increasing availability of very high field systems, third- and fourth-order terms are a serious consideration. However, choosing appropriate coil strengths is of critical importance in shim coil design since overspecification of the shim strengths can lead to a variety of problems, including shim coil self-resonance. In this study B(0) field map data collected over a period of 6 months (over 400 brain volumes) were analyzed to find the characteristic B-fields required to shim these brains. These data can be used to specify the coil requirements to effectively shim the human brain.

Brain Mapping↗

High-resolution FMRI at 1.5T using balanced SSFP.

The resolution in conventional BOLD FMRI is considerably lower than can be achieved with other MRI methods, and is insufficient for many important applications. One major difficulty in robustly improving spatial resolution is the poor image quality in BOLD FMRI, which suffers from distortions, blurring, and signal dropout. This work considers the potential for increased resolution with a new FMRI method based on balanced SSFP. This method establishes a blood oxygenation sensitive steady-state (BOSS) signal, in which the frequency sensitivity of balanced SSFP is used to detect the frequency shift of deoxyhemoglobin. BOSS FMRI is highly SNR efficient and does not suffer from image distortions or signal dropout, making this method an excellent candidate for high-resolution FMRI. This study presents the first demonstration of high-resolution BOSS FMRI, using an efficient 3D stack-of-segmented EPI readout and combined acquisition at multiple center frequencies. BOSS FMRI is shown to enable high-resolution FMRI data (1 x 1 x 2 mm(3)) in both visual and motor systems using standard hardware at 1.5 T. Currently, the major limitation of BOSS FMRI is its sensitivity to temporal and spatial field drift.

Brain Mapping↗

Physical and physiological consequences of passive intra-oral shimming.

Imaging the human orbitofrontal cortex (OFC) with fMRI is problematic due to the proximity of this region to the air-filled sinuses, which causes susceptibility artifacts. Placing a strongly diamagnetic material into the mouth ('mouthshim') of a human volunteer can significantly reduce the artifacts in this region. Using the same combined olfactory and visual fMRI paradigm, we compared brain activation and static B0 field maps of participants being scanned both with and without the 'mouthshim'. Results demonstrate that the device improves the B0 field homogeneity within OFC, resulting in significantly stronger BOLD activation in this region. However, the device also caused both increased head motion and reduced activation in insular cortices due to more frequent swallowing and tactile stimulation of the tongue. The 'mouthshim' should only, therefore, be used where sensitivity in OFC regions is paramount.

Adult↗

Independent anatomical and functional measures of the V1/V2 boundary in human visual cortex.

The cerebral cortex has both anatomical and functional specialization, but the level of correspondence between the two in the human brain has remained largely elusive. Recent successes in high-resolution magnetic resonance imaging of myeloarchitecture patterns in the cortex suggest that it may now be possible to compare directly human anatomy and function in vivo. We independently investigated the anatomical and functional borders between primary and secondary human visual areas (V1 and V2) in vivo. Functional borders were mapped with functional magnetic resonance imaging (fMRI) using a narrow, vertical black and white contrast-reversing wedge. In three separate scanning sessions, anatomical images were collected at three different slice orientations (300 microm x 300 microm, slice thickness, 1.5 mm). The anatomical signature of V1 was determined by the presence of a hypointense band in the middle of the cortical gray matter. The band was identified in between 81% and 33% (mean 57%) of V1 defined using fMRI, and less than 5% of the identified band was in cortex outside V1. Intensity profiles taken through the gray matter on the V1 and V2 sides of the functional border indicate a measurable difference in the size of the hypointense band for all subjects. This is the first demonstration that the definition of V1 by fMRI closely matches the anatomically defined striate cortex in the human brain. The development of very high-resolution structural MRI may permit the definition of cortical areas based on myeloarchitecture when functional definition is not possible.

Adult↗

Quantitative perfusion measurements using pulsed arterial spin labeling: effects of large region-of-interest analysis.

PURPOSE: To study arterial spin labeling (ASL) MRI techniques and to investigate various problematic issues that still hinder the accurate and robust quantitative analysis of ASL data. MATERIALS AND METHODS: A pulsed-ASL (PASL) sequence was implemented on a 3-T imaging system and a protocol was developed for the measurement of perfusion based on fitting to a standard kinetic model. Both numerical simulations and multi-inversion time MRI data were analyzed. The effect of fitting a kinetic curve to a large region of interest (ROI) with a distribution of arterial transit times was compared to a pixel-by-pixel (PBP) method. RESULTS: It was found that a significant underestimation of perfusion of approximately 17+/-6% (P<0.001) occurs in gray matter, when comparing an ROI with a PBP analysis over a group of 12 healthy subjects. CONCLUSION: Analysis of ASL data based on a large ROI may suffer from inaccuracies arising from a distribution of transit times, implying that averaging of ASL kinetic data over such regions should therefore be avoided. When possible, a PBP fit should be performed.

Adult↗

Calibration of gradient propagation delays for accurate two-dimensional radiofrequency pulses.

Hardware-related delays between the requested and actual start times of the gradient waveforms on each physical axis are of particular importance for multidimensional selective excitation in which the synchronization of gradient and radiofrequency (RF) waveforms is critical. A method is proposed for the accurate calibration of gradient propagation delays to optimize the spatial accuracy of 2D RF pulses, although the results may also be used to reduce artifacts in other MR techniques. The sensitivity of 2D RF pulses to uncorrected time shifts between the gradient and RF waveforms was exploited to calibrate accurately the propagation delays on each physical gradient axis. This was achieved using a technique that relates the effect of gradient delays in the component waveforms of a constant-angular rate spiral k-space trajectory 2D RF pulse to the spatial location of the subsequent excitation profile. Comparison was also made with a procedure based on a previously described k-space plotting method, showing broad agreement, but with some discrepancies that illustrate the value of a self-referenced correction method for multidimensional RF pulses.

Calibration↗

Self-navigated multishot echo-planar pulse sequence for high-resolution diffusion-weighted imaging.

Single-shot techniques have preferentially been adopted for diffusion-weighted imaging due to their reduced sensitivity to bulk motion. However, the limited spatial resolution achievable results in orientational signal averaging within voxels containing a distribution of fibers. This leads to impaired performance of tracking algorithms. To combat partial volume effects, high-resolution multishot techniques can be used but, being more sensitive to motion, require phase correction to obtain artifact-free images. While separately acquiring 2D navigator echoes is an effective approach, it is not very efficient as the navigators do not contribute signal to the final image. Here a self-navigated interleaved echo planar imaging (EPI) sequence based on EPI with keyhole (EPIK) is proposed. The refocusing reconstruction method is successfully adapted to EPIK and compared to the standard linear approach. The resultant improvement in resolution is shown to lead to a significant increase in anisotropy in fiber-branching areas and can potentially offer a superior ability to detect fine tract splits.

Algorithms↗

Investigations on the efficiency of cardiac-gated methods for the acquisition of diffusion-weighted images.

Diffusion-weighted images are inherently very sensitive to motion. Pulsatile motion of the brain can give rise to artifactual signal attenuation leading to over-estimation of the apparent diffusion coefficients, even with snapshot echo planar imaging. Such miscalculations can result in erroneous estimates of the principal diffusion directions. Cardiac gating can be performed to confine acquisition to the quiet portion of the cycle. Although effective, this approach leads to significantly longer acquisition times. On the other hand, it has been demonstrated that pulsatile motion is not significant in regions above the corpus callosum. To reduce acquisition times and improve the efficiency of whole brain cardiac-gated acquisitions, the upper slices of the brain can be imaged during systole, reserving diastole for those slices most affected by pulsatile motion. The merits and disadvantages of this optimized approach are investigated here, in comparison to a more standard gating method and to the non-gated approach.

Artifacts↗

Distinct portions of anterior cingulate cortex and medial prefrontal cortex are activated by reward processing in separable phases of decision-making cognition.

BACKGROUND: Choosing between actions associated with uncertain rewards and punishments is mediated by neural circuitry encompassing the orbitofrontal cortex, anterior cingulate cortex (ACC), and striatum; however, the precise conditions under which these different components are activated during decision-making cognition remain uncertain. METHODS: Fourteen healthy volunteers completed an event-based functional magnetic resonance imaging protocol to investigate blood-oxygenation-level-dependent (BOLD) responses during independently modeled phases of choice cognition. In the "decision phase," participants decided which of two simultaneous visually presented gambles they wished to play for monetary reward. The gambles differed in their magnitude of gains, magnitude of losses, and the probabilities with which these outcomes were delivered. In the "outcome phase," the result of each choice was indicated on the visual display. RESULTS: In the decision phase, choices involving large gains were associated with increased BOLD responses in the pregenual ACC, paracingulate, and right posterior orbitolateral cortex compared with choices involving small gains. In the outcome phase, good outcomes were associated with increased BOLD responses in the posterior orbitomedial cortex, subcallosal ACC, and ventral striatum compared with negative outcomes. There was only limited overlap between reward-related activity in ACC and orbitofrontal cortex during the decision and outcome phases. CONCLUSIONS: Neural activity within the medial and lateral orbitofrontal cortex, pregenual ACC, and striatum mediate distinct representations of reward-related information that are deployed at different stages during a decision-making episode.

Adult↗

Perturbation method for magnetic field calculations of nonconductive objects.

Inhomogeneous magnetic fields produce artifacts in MR images including signal dropout and spatial distortion. A novel perturbative method for calculating the magnetic field to first order (error is second order) within and around nonconducting objects is presented. The perturbation parameter is the susceptibility difference between the object and its surroundings (for example, approximately 10 ppm in the case of brain tissue and air). This method is advantageous as it is sufficiently accurate for most purposes, can be implemented as a simple convolution with a voxel-based object model, and is linear. Furthermore, the method is simple to use and can quickly calculate the field for any orientation of an object using a set of precalculated basis images.

Head↗

The cortical organization of audio-visual sentence comprehension: an fMRI study at 4 Tesla.

Neuroimaging studies of written and spoken sentence processing report greater left hemisphere than right hemisphere activation. However, a large majority of our experience with language is face-to-face interaction, which is much richer in information. The current study examines the neural organization of audio-visual (AV) sentence processing using functional magnetic resonance imaging (fMRI) at 4 Tesla. Participants viewed the face and upper body of a speaker via a video screen while listening to her produce, in alternating blocks, English sentences and sentences composed of pronounceable non-words. Audio-visual sentence processing was associated with activation in the left hemisphere in Broca's area, dorsolateral prefrontal cortex, the superior precentral sulcus, anterior and middle portions of the lateral sulcus, middle superior portions of the temporal sulcus, supramarginal gyrus and angular gyrus. Further, AV sentence processing elicited activation in the right anterior and middle lateral sulcus. Between-hemisphere analyses revealed a left hemisphere dominant pattern of activation. The findings support the hypothesis that the left hemisphere may be biased to process language independently of the modality through which it is perceived. These results are discussed in the context of previous neuroimaging results using American Sign Language (ASL).

Adult↗

Methamphetamine activates reward circuitry in drug naïve human subjects.

Amphetamines are highly addictive drugs that have pronounced effects on emotional and cognitive behavior in humans. These effects are mediated through their potent dopaminergic agonistic properties. Dopamine has also been implicated in the modulation of responses of the 'reward circuit' in animal and human studies. In this study we use functional magnetic resonance imaging (fMRI) to identify the brain circuitry involved in the psychostimulant effect of methamphetamine in psychostimulant-naïve human subjects. Seven healthy volunteers were scanned in a 3T MR imaging system. They received single-blind intravenous infusions of methamphetamine (0.15 mg/kg), and rated their experience of 'mind-racing' on a button press throughout the experiment. Data were analyzed with statistical parametric mapping methods. Amphetamine administration activated the medial orbitofrontal cortex, the rostral part of the anterior cingulate cortex, and the ventral striatum. Ratings of 'mind-racing' after methamphetamine infusion correlated with activations in the rostral part of the anterior cingulate cortex and in the ventral striatum. In addition, activations in the medial orbitofrontal cortex were independent of motor and related responses involved in making the ratings. These findings indicate that the first administration of a psychostimulant to human subjects activates classical reward circuitry. Our data also support recent hypotheses suggesting a central role for the orbitofrontal cortex in drug reinforcement and the development of addiction.

Adult↗

Increased brain GABA concentrations following acute administration of a selective serotonin reuptake inhibitor.

OBJECTIVE: The authors used magnetic resonance spectroscopy (MRS) to assess the effect of acute administration of the selective serotonin reuptake inhibitor (SSRI) citalopram on cortical levels of gamma-aminobutyric acid (GABA). METHOD: Ten healthy volunteers received either intravenous citalopram (10 mg) or saline in a randomized, double-blind, crossover design. The occipital GABA/creatine ratio was measured with a proton MR spectral editing technique. RESULTS: In comparison with saline, citalopram produced a mean increase of 35% in relative brain GABA concentration in the occipital cortex. CONCLUSIONS: These findings extend previous work showing that SSRI treatment increases cortical GABA in depressed patients and suggest that this results from an action of SSRIs on GABA neurons rather than as a secondary consequence of mood improvement.

Adult↗

Functional asymmetry for auditory processing in human primary auditory cortex.

Structural asymmetries in the supratemporal plane of the human brain are often cited as the anatomical basis for the lateralization of language predominantly to the left hemisphere. However, similar asymmetries are found for structures mediating earlier events in the auditory processing stream, suggesting that functional lateralization may occur even at the level of primary auditory cortex. We tested this hypothesis using functional magnetic resonance imaging to evaluate human auditory cortex responses to monaurally presented tones. Relative to silence, tones presented separately to either ear produced greater activation in left than right Heschl's gyrus, the location of primary auditory cortex. This functional lateralization for primary auditory cortex is distinct from the contralateral dominance reported for other mammals, including nonhuman primates, and may have contributed to the evolution of a unique role for the left hemisphere in language processing.

Adult↗

Theoretical and experimental evaluation of detached endcaps for 3 T birdcage coils.

The use of detached endcaps for 3 T birdcage coils was investigated both theoretically and experimentally. Finite difference time domain analysis, along with workbench and MRI techniques, were used to map the radiofrequency (RF) B(1) distribution along the coil axis with and without an endcap. Without an endcap the measured B(1) value at the service end of the birdcage was only 45% of the value at the coil's center. This was improved to 85% with a detached endcap of maximum achievable diameter (375 mm), positioned 4 mm from the RF shield. The B(1) field distribution on the patient side of the coil was unaffected by the presence of the endcap. The dependence of the B(1) distribution as a function of endcap diameter was also investigated. Surprisingly, simulations and experiments show that there is an optimum ratio of endcap-to-birdcage coil diameter (approximately 1.08) that gives the best B(1) homogeneity. In the human head the optimized endcap, positioned 16 mm from the RF shield, improves the MRI signal amplitude from 55% to 85% of maximum toward the service end. This novel endcap design is easy to implement with existing birdcage coils, and could prove useful when flexibility in access to the RF coil is required.

Equipment Design↗

Selective arterial spin labeling (SASL): perfusion territory mapping of selected feeding arteries tagged using two-dimensional radiofrequency pulses.

To date, most perfusion magnetic resonance imaging (MRI) methods using arterial spin labeling (ASL) have employed slab-selective inversion pulses or continuous labeling within a plane in order to obtain maps derived from all major blood vessels entering the brain. However, there is great potential for gaining additional information on the territories perfused by the major vessels if individual feeding arteries could be tagged. This study demonstrates noninvasive arterial perfusion territory maps obtained using two-dimensional (2D) selective inversion pulses. This method is designated "selective ASL" (SASL). The SASL method was used to tag the major arteries below the circle of Willis. A combination of 2D selective tagging and multislice readout allows perfusion territories to be clearly visualized, with likely applications to cerebrovascular disease and stroke.

Brain↗

Utilization of an intra-oral diamagnetic passive shim in functional MRI of the inferior frontal cortex.

Due to the presence of gross magnetic susceptibility artifacts, functional MRI (fMRI) has proved problematic in studies of the human inferior frontal cortex (IFC). There is a strong desire, therefore, to employ techniques that mitigate susceptibility artifacts in the IFC while preserving the imaging parameters of an fMRI study. It has been shown that the use of a single, strongly diamagnetic, intra-oral passive shim significantly improves the homogeneity of the static magnetic field (B(0)) and, as a result, alleviates the susceptibility artifacts within the IFC. In this study, practical issues regarding the use of an intra-oral passive shim are examined. We investigated B(0) instabilities within the IFC resulting from subject head motion in order to calculate the effects of an intra-oral passive shim on the temporal variance of an EPI time series. These studies show that the addition of an intra-oral passive shim improves both B(0) homogeneity and signal stability, and increases sensitivity to functional activation.

Artifacts↗

Protocol to determine the optimal intraoral passive shim for minimisation of susceptibility artifact in human inferior frontal cortex.

At higher static magnetic field (B(0)) strengths (>/=3 T), the study of human inferior frontal cortex (IFC) when utilising a variety of MRI techniques is severely hampered by the presence of susceptibility artifacts. This is particularly the case for blood oxygenation level-dependent functional MRI, where large signal voids are generally encountered in the frontal lobes. A previous study described an approach to artifact correction involving a mouth insert consisting of a prototype diamagnetic passive shim [Magn. Reson. Med. 48 (2002), 906]. Here we extend that method by investigating the effect of five different intraoral passive shims on B(0) homogeneity and echoplanar imaging susceptibility artifacts within the brain, and particularly the IFC, of six subjects. The optimal passive shim is shown to be subject- and study-specific, providing an average reduction in mean absolute B(0) offset within the IFC of 57%, along with a concomitant reduction in echoplanar susceptibility artifact. All subjects were at ease while wearing the intraoral shims. A 4-min in vivo protocol to determine the optimal passive shim from the available set, utilising intrinsic structural and B(0) subject data, is described and shown to be accurate and reliable.

Artifacts↗