PubMed Health⌕ Search

Biomedical subjects

Peter Keppler

Publications and source records attributed to Peter Keppler.

6 recordsLinked to original sources

Hybrid external fixation for arthrodesis in knee sepsis.

Several techniques for knee fusion have been described with success rates ranging from 29% to 100%, with worse results occurring in patients with joint sepsis. We treated 21 patients with persistent infections using knee arthrodesis with a hybrid Ilizarov frame at our institution. There were 13 men and eight women ranging from 21 to 75 years (mean, 49.7 years). Sixteen patients had chronic osteomyelitis and five had previous fusion trials. Two patients required bone transport using the same arthrodesis frame. We corrected associated malalignment in three patients. Solid knee fusion was achieved in all but one patient after a mean external fixation time of 22.7 weeks (range, 11-47 weeks). Limb shortening averaged 2.8 cm (range, 1.5-5 cm). No patients required secondary bone grafting to achieve fusion. Nine patients had complications develop, three of whom required reresection and frame application to treat persistent infection or delayed union. Our results emphasize the clinical success of using the Ilizarov fixator for knee arthrodesis after persistent sepsis.

Adult↗

Limb malalignment and functional outcome after antegrade versus retrograde intramedullary nailing in distal femoral fractures.

BACKGROUND: Torsional malalignment and mechanical axis deviation (MAD) are worrisome complications after nailing of distal femoral fractures. Variable, sometimes contradictory, reports about these problems have been published. METHODS: In a retrospective nonrandomized study, 41 patients (mean age, 44.5 years) with distal third femoral fractures that were operatively treated using either antegrade (20 cases) or retrograde (21 cases) intramedullary nailing during a period of 2 years have been reviewed. Goniometric measurement was done using a navigated ultrasound examination whereas functional evaluation and return to sports were assessed using Merle d'Aubigné functional grading system and Tegner and Lysholm activity score. RESULTS: There was no difference in femoral length, torsion, or MAD between patients treated using antegrade nails and those treated with a retrograde nail. There was a greater limitation of knee motion with retrograde nailing and of hip motion with antegrade nailing. The functional grading and activity evaluation showed, however, no difference between both groups. CONCLUSIONS: The study cohort showed that no treatment method had proved an advantage over the other regarding limb geometry or the functional outcome. The proper operative indication, intraoperative control, and the surgeon's experience seem to be more important in this regard than the nailing technique.

Adolescent↗

Implementation, accuracy evaluation, and preliminary clinical trial of a CT-free navigation system for high tibial opening wedge osteotomy.

OBJECTIVE: The objectives of this study are to design and evaluate a CT-free intra-operative planning and navigation system for high tibial opening wedge osteotomy. This is a widely accepted treatment for medial compartment osteoarthritis and other lower extremity deformities, particularly in young and active patients for whom total knee replacement is not advised. However, it is a technically demanding procedure. Conventional preoperative planning and surgical techniques have so far been inaccurate, and often resulting in postoperative malalignment representing either under- or over-correction, which is the main reason for poor long-term results. In addition, conventional techniques have the potential to damage the lateral hinge cortex and tibial neurovascular structures, which may cause fixation failure, loss of correction, or peroneal nerve paralysis. All these common problems can be addressed by the use of a surgical navigation system. MATERIALS AND METHODS: Surgical instruments are tracked optically with the SurgiGATE((R)) navigation system (PRAXIM MediVision, La Tronche, France). Following exposure, dynamical reference bases are attached to the femur, tibia, and proximal fragment of the tibia. A patient-specific coordinate system is then established, on the basis of registered anatomical landmarks. After intra-operative deformity measurement and correction planning, the osteotomy is performed under navigational guidance. The deformities are corrected by realigning the mechanical axis of the affected limb from the diseased medial compartment to the healthy lateral side. The wedge size, joint line orientation, and tibial plateau slope are monitored during correction. Besides correcting uni-planar varus deformities, the system provides the functionality to correct complex multi-planar deformities with a single cut. Furthermore, with on-the-fly visualization of surgical instruments on multiple fluoroscopic images, penetration of the hinge cortex and damage to the neurovascular structures due to an inappropriate osteotomy can be avoided. RESULTS: The laboratory evaluation with a plastic bone model (Synbone AG, Davos, Switzerland) shows that the error of deformity correction is <1.7 degrees (95% confidence interval) in the frontal plane and <2.3 degrees (95% confidence interval) in the sagittal plane. The preliminary clinical trial confirms these results. CONCLUSION: A novel CT-free navigation system for high tibial osteotomy has been developed and evaluated, which holds the promise of improved accuracy, reliability, and safety of this procedure.

Arthroscopy↗

Computer aided high tibial open wedge osteotomy.

High tibial osteotomy is a widely accepted treatment of medial compartment osteoarthritis as well as other lower extremity deformities. However, it is a technically demanding procedure. The lack of exact intraoperative real time control of the mechanical axis often results in postoperative malalignments, which is one reason for poor long term results. These problems can be addressed with the use of a surgical navigation system. Following exposure, dynamic reference bases (DRBs) are attached to the femur, and the proximal and the distal part of the tibia. After intraoperative measurement of the deformities and correction planning, the osteotomy is performed under navigational guidance. The wedge size, joint line orientation, and tibial plateau slope are monitored during correction. The in vitro evaluation with a plastic bone model suggests that the error of deformity correction is less than 1.7 degrees (95% confidence limits) in the frontal, and less than 2.3 degrees (95% confidence limits) in the sagittal plane, respectively. On a cadaver study of 13 legs, the mechanical axis intersected the Fujisawa line in 80.7% (range 77.5-85.8%). The preliminary clinical experience confirms these results. A novel computer tomography free navigation system for high tibial osteotomy has been developed that holds the promise of improving the accuracy, reliability, and safety of this kind of approach.

Adult↗

The effectiveness of physiotherapy after operative treatment of supracondylar humeral fractures in children.

The indications for physiotherapy after supracondylar humeral fractures in children are not clear in the literature, even in the presence of an active or passive limitation of elbow joint motion. The authors therefore performed a prospective randomized study to assess the effectiveness of physiotherapy in improving the elbow range of motion after such fractures. The authors studied two groups of 21 and 22 children with supracondylar humeral fractures Felsenreich types II and III, all without associated neurovascular deficits. All children were treated by open reduction and internal fixation with Kirschner wires inserted from the radial side of the humerus. Postoperative follow-up at 12 and 18 weeks showed a significantly better elbow range of motion in the group with weekly physiotherapy, but there was no difference in elbow motion after 1 year. In each group, one child had an extension deficit of 15 or 20 degrees. The authors conclude that postoperative physiotherapy is unnecessary in children with supracondylar humeral fractures without associated neurovascular injuries.

Child↗

Flexible intramedullary nailing in pediatric lower limb fractures.

Seventy-three children (48 boys and 25 girls; mean age, 5.7 years) with unilateral femoral or tibial shaft fractures were treated using elastic intramedullary nails at the authors' institution. There were 61 simple type A fractures (84%) and 12 wedge type B fractures (16%). All but 3 children had closed fractures. Associated injuries were seen in one third of the cases. All fractures were reduced by closed manipulation. Union was achieved in all cases without additional intervention. Technical problems occurred in few patients. Improper nail length was seen in 4 cases. None of the study patients developed deep infection. No angulation greater than 15 degrees was found after femoral fractures. Nine patients had length discrepancy greater than 10 mm. Spiral fractures showed a tendency for shortening whereas transverse fractures were more associated with post-traumatic lengthening. No significant axial malalignment or shortening was seen in tibial fractures. Torsional differences of greater than 15 degrees were detected by computed tomography or navigated ultrasound examination in nearly half of the patients; however, only 4 children had clinically apparent gait changes. The study confirms the satisfactory results of treating pediatric lower limb fractures using elastic nails. Proper surgical technique and intraoperative control of limb alignment can help avoid postoperative deformities.

Bone Nails↗